5Regency I43-1 ULTIMATE Gas Inbuilt Fireplace
INSTALLATION REQUIREMENTS
IMPORTANT:
SAVE THESE INSTRUCTIONS
The Regency I43-1 Gas Fireplace must be installed in
accordancewiththeseinstructions.Carefullyreadallthe
instructions in this manual first. Consult the "authority
having jurisdiction" to determine the need for a permit
prior to starting the installation.
Note: Failure to follow these instructions could cause
a malfunction of the heater which could result in death,
seriousbodily injury, and/orproperty damage. Failureto
followtheseinstructionsmayalsovoidyourfireinsurance
and/or warranty.
FOR YOUR SAFETY
Thisappliancerequiresairforpropercombustion.Always
provideadequate combustionandventilationair.Follow
instructionsandinformationin thecurrentAS5601-2004
or local codes.
GAS PIPE TESTING
Theappliance must be isolatedfrom the gas supplypip-
ing system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig. (3.45 kPa).
SPECIFICATIONS
Fuel: NG or LPG
Electrical: 240 volt. system
Fan: 2 speed, 75/125 CFM
Log Sets: Ceramic fibre, 3 per set
BEFORE YOU START
Installation is to be carried out ONLY by an authorised
person.
1) The appliance shall be installed in accordance with
themanufacturer'sinstallationinstructions,localgas
fitting regulations, municipal building codes, water
supply regulations, electrical wiring regulations,
withAS5601-2004 (AGAgas installation code) NZS
5261(New Zealand)
2) Installation and repair should be done ONLY by
an authorised person.
3) The appliance should be inspected before use and
at least annually by an authorised service person.
More frequent cleaning may be required due to ex-
cessive lint from carpeting, bedding material, etc. It
isimperativethatcontrolcompartments,burnersand
circulatingairpassagewaysoftheappliancebykept
clean and free from excessive lint from carpeting.
4) See general construction and assembly instruc-
tions. This appliance may only be installed in a
flued noncombustible fireplace. The appliance and
flue should be enclosed when installed or passing
through a living area, where children may come in
contact with it.
5) Alwaysconnectthisfireplacetoa fluetotheoutside
ofthebuildingenvelope.Neverfluetoanotherroom.
Make sure that the flue is properly sized and is of
adequate height to provide the proper draft.
6) Inspect the flue system annually for blockage and
any signs of deterioration.
7) Any safety glass removed for servicing must be
replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who is unfa-
miliar with the operation to use the fireplace.
9) Installer must mechanically attach the supplied label to
the inside of the firebox of the fireplace into which the gas
fireplace insert is installed.
“WARNING: This fireplace has been converted for use with a
gas fireplace insert only and cannot be used for burning wood
or solid fuels unless all original parts have been replaced, and