Relay RA320 Handbuch

HARDWARE INSTALLATION GUIDE
RA320 AI-ENABLED ACCESS POINT
Doc No.: PRDT-0055 | Version 2.0 | Date 2023-08-23

RELAY2
TRADEMARKS
COMPANY HEADQUARTERS
The Relay2 logo is a trademark of Relay2, Inc. of the
US.
1525 McCarthy Boulevard, Suite 209
Milpitas, CA 95035, USA
www.relay2.com
+1 (408) 380-0031
PRODUCT OVERVIEW
The RA300 family is a cloud-managed Service-
Ready Access Point (SR-AP) offering Edge
Computing and storage capabilities with a high-
performance wireless access point integrated.
It enables businesses to deliver superior venue
experiences, enhance business operations, and
create competitive advantages. The RA300 family
consists of various models—including the RA320
and RA340—to support various capacity and
deployment needs. For more information about the
RA300 family, refer to www.relay2.com.

Opening the Package
• Please ensure that all ordered optional
accessories are included in the separate
accessory box.
• Please check the packaging list rst. If there are
any missing or broken parts, please contact the
authorized distributor of Relay2, Inc.
Warranty
• Please provide the device model, MAC address,
and serial number shown on the tag of the side
panel.
• The warranty does not cover any product that
has been opened without authorization from
Relay2 Inc.
• Reasonable repair and shipping costs will be
charged for product faults or damage caused
by using non-Relay2 accessories or improper
operation.
Power Source Options
• The RA320 access point can be powered by using
the external Relay2 AC Adapter, PoE Injector (both
sold separately), or a third-party PoE+ switch.
Safety
• Read the Quick Installation Guide carefully before
installation and power-up.
• To avoid overheating, make sure the AP allows for
proper heat dissipation, and leave enough room
for air circulation.
• Do not directly touch the bottom of the AP to
avoid scalding. When the AP is in operation,
depending on the environment’s temperatures,
the surface temperature of the back cover might
get hot.
• Any unauthorized modication of the product
structure and safety design is not allowed.
Before You Start
• Before installation, a signal detecting test can be
used to determine the best installation position.
• Keep your body at least 20 cm away from the AP
during installation and operation.
• Install the AP at least 1 m distance from any
metal obstructions to avoid the radio signal
being affected by metal shielding.
• To avoid radio interference, keep the device
away from magnets or magnetic elds (e.g., do
not place near a microwave, refrigerator, etc.).

PACKAGE CONTENT - RA320
Access Point
Wall Mount Kit
M3.5 screws and anchors
for masonry
T-Rail Mount Kit

AP OVERVIEW
Interfaces
LED Indicators
Kensington Lock Hard Point

Wall Mount the AP
• Determine where the AP is to be placed and mark the location on the surface for the
two mounting holes. You may adjust the position with a level.
• Use the appropriate drill bit to drill two 4 mm wide and 37 mm deep holes and insert
the screw anchors into the openings. Fasten the mounting plate with the provided
screws.
• Slide the AP into the wall mounting plate.

T-Rail Mount the AP
• Adjust the T-rail mount to the used T-rail size and x the mounting bracket to the T-rail.
• Slide the AP into the T-rail mount.
T-Rail 14.3 mm
T-Rail 23.8 mm
T-Rail 38 mm

Kensington Lock - Security Feature
• Attach a Kensington lock cable to the access point at the hard point on the
side of the RA320.
• Attach the other end of the cable to a secure location, such as a pipe or
building xture.

VERIFY RA320 FUNCTIONALITY
Table 1 RA320 LED booting states
States AP Status LED Display
State 1: Power on Solid green
State 2: R2OS starting Amber solid for 2 seconds
State 3: R2OS initializing Amber blinking
State 4: Radio up and ready Not affected
State 5: SCM connecting Green blinking
State 6: CWCL connecting Green fast blinking
State 7: AP up and running Green solid
State 8: Image upgrade Amber blinking
State 9: AP radio down Not affected
First, check if the status LED is solid green. During the rst boot, it is highly likely that the
AP is automatically updating its rmware, indicated by an amber blinking status LED. The
status LED should turn solid green after the upgrade process has nished (normally within
a few minutes). See the LED indicator table below for more details.
Verify access point connectivity—use any 802.11 client device to connect to the RA320 AP
and verify network connectivity using the client device web browser by going to a well-
known web page.
Check network coverage and conrm good signal strength in the desired coverage area.

FCC Disclaimer
§ 15.19 Labeling Requirements
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
§ 15.21 Information to User
Any changes or modications not expressly
approved by the party responsible for compliance
could void the user’s authority to operate the
equipment.
§ 15.105 Information to the User
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates uses and can radiate radio
frequency energy and, if not installed and used
in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to
radio or television reception, resolve the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and the receiver.
• Connect the equipment to an outlet on a circuit
different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV
technician for help.
This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated
with a minimum distance of 20 cm between the
radiator and your body.
Operations in the 5.15–5.35 GHz band are restricted
to indoor usage only.
Inhaltsverzeichnis
Beliebte Drahtloser Zugangspunkt Handbücher anderer Marken

D-Link
D-Link DWL-2100AP - AirPlus Xtreme G Bedienungsanleitung

Ubiquiti
Ubiquiti NanoStation NSM2 Bedienungsanleitung

Cisco
Cisco Aironet 1550 Series Bedienungsanleitung

Aruba
Aruba IAP-335 Bedienungsanleitung

Advantek Networks
Advantek Networks AWN-AP-54MR Bedienungsanleitung

IP-COM
IP-COM AP355 Bedienungsanleitung

Buffalo
Buffalo AirStation WLA-L11G Bedienungsanleitung

EnGenius
EnGenius EnStationACv2 Bedienungsanleitung

D-Link
D-Link DAP-3662 Bedienungsanleitung

xG Technology
xG Technology xMax CN1300 Bedienungsanleitung

Widelink
Widelink ezWave WAP-1100 Series Bedienungsanleitung

Edimax
Edimax CAP1200 Bedienungsanleitung