Retekess T-AC03 Bedienungsanleitung

Metal Standalone Keypad Access Control
User Manual
T-AC03
EU

CONTENTS
Description
Features
Specifications
Packing List
Installation
Wiring
To Reset to Factory Default
Anti Tamper Alarm
Sound and Light indication
Detailed Programming Guide
The unit operating as a Wiegand Output
Reader
INHALT
Beschreibung
Eigenschaften
Spezifikationen
Packliste
Installation
Verkabelung
Zurücksetzen auf Werkseinstellungen
Diebstahlschutz Alarm
Ton- und Leichte Anweisungen
Detaillierte Programmieranleitung
Das Gerät arbeitet als Wiegand Output
Reader
Catalogue
Description
Caractéristiques
Spécification
Contenu de l’emballage
Installation
Câblage
Pour reinitialiser les réglages par défaut
Alarme d’antivol
Indicateur de bip sonore et les témoins
lumineux
Guide de programmation détaillé
L'unité fonctionnant comme un lecteur
de sortie Wiegand
.................................................01
.....................................................01
.............................................01
...............................................02
..................................................02
.........................................................02
......................04
.....................................04
........................04
....................04
........................................................07
.............................................08
............................................08
...........................................08
.....................................................09
..................................................09
...............................................09
........11
................................11
..................11
.............11
........................................................15
.................................................16
.........................................16
...............................................16
.............................17
..................................................17
......................................................17
....19
..........................................19
.....................................................19
...............19
......................................23
CONTENUTO
Descrizione
Caratteristiche
Specificazione
Lista imballaggio
Installazione
Schema cablaggio
Ripristinare i valori predefiniti di fabbrica
Allarme Anti-manomissione
Indicazione suono e LED
Guida alla programmazione dettagliata
L'unità funziona come un lettore di uscita
Wiegand
CONTENIDO
Descripción
Funciones
Especificaciones
Lista de embalaje
Instalación
Cable
Restaura la configuración de fábrica
Alarma antimanipulación
Indicación de sonido y luz
Guía detallada de programación
Funciona como lector de salida
Wiegand
WARNING
.................................................24
............................................24
............................................24
........................................25
...............................................25
.....................................25
...27
.......................27
............................27
.....27
.....................................................30
................................................31
...................................................31
........................................31
.......................................32
..................................................32
..........................................................32
.........34
...........................34
..........................34
................34
.....................................................38

Operating Voltage DC 12V±10%
User Capacity 2000
Card Reading Distance 3-6 cm
Active Current <60mA
Idle Current 25±5 mA
Lock Output Load Max 3A
Alarm Output Load Max 20A
Operating Temperature -45℃~60℃
Operating Humidity 10%- 90% RH
Waterproof Conforms to IP68
Adjustable Door Relay time 0 -99 seconds
Adjustable Alarm Time 0- 3 minutes
Wiegand Interface Wiegand 26 bit
Wiring Connections Electric Lock, Exit Button, External Alarm,External reader
1
Description
The unit is single door multifunction standalone access controller or a Wiegand output keypad or
card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed
in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a
bright silver or matt silver finish. The electronics are fully potted so the unit is waterproof and
conforms to IP68. This unit supports up to 2000 users in either a Card, 4 digit PIN, or a Card + PIN
option. The inbuilt card reader supports 125KHZ EM cards,13.56MHz Mifare cards. The unit has
many extra features including lock output current short circuit protection, Wiegand output , and a
backlit keypad. These features make the unit an ideal choice for door access not only for small
shops and domestic households but also for commercial and industrial applications such as
factories, warehouses, laboratories, banks and prisons.
Features
• Waterproof, conforms to IP68
• Strong Zinc Alloy Electroplated anti-vandal case
• Full programming from the keypad
• 2000 uses, supports Card, PIN, Card + PIN
• Can be used as a stand alone keypad
• Backlight keys
• Wiegand 26 input for connection to external reader
• Wiegand 26 output for connection to a controller
• Adjustable Door Output time, Alarm time, Door Open time
• Very low power consumption (30mA)
• Fast operating speed, <20ms with 2000 users
• Lock output current short circuit protection
• Easy to install and program
• Built in light dependent resistor (LDR) for anti tamper
• Built in buzzer
• Red, Yellow and Green LEDS display the working status
Specifications

Please ensure that all the above contents are correct. If any are missing please notify the supplier
of the unit.
Installation
• Remove the back cover from the keypad using the supplied special screw driver
• Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
• Put the supplied rubber bungs to into the two holes
• Fix the back cover firmly on the wall with 2 Self tapping screws
• Thread the cable through the cable hole
• Attach the keypad to the back cover
Wiring
2
Colour
Function
Description
Pink BELL_A Doorbell button one end
Pale blue BELL_B Doorbell button to the other end
Green D0 WG output D0
White D1 WG output D1
Grey ALARM Alarm negative(alarm positive connected 12 V+)
Yellow OPEN Exit button one end(the otherend connected GND)
Brown D_IN Magnetic switch one end(the other end connected GND)
Red 12V+ 12V + DC Regulated Power Input
Black GND 12V - DC Regulated Power Input
Blue NO Relay normally-on end(Connect positive electric lock "-")
Purple COM Relay Public end, connect GND
Orange NC Relay Closed end(connect negative electric lock "-")
Packing List
Name Quantity Remarks
Keypad 1
User manual 1
Screw driver 1 Φ20mm×60mm,Special for keypad
Rubber plug 2 Φ6mm×30 mm, used for fixing
Self tapping screws 2 Φ4mm×28 mm, used for fixing
Star screws 1Φ3mm×6mm, used for fixing

3
special power supply diagram:
common power supply diagram:

To Reset to Factory Default
a. Disconnect power from the unit
b. Press and hold # key whilst powering the unit back up
c. On hearing two “Di” release # key, system is now back factory settings
NOTE: note only installer data is restored, user data will not be affected
Anti Tamper Alarm
The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed
from the cover then the tamper alarm will operate.
Sound and Light indication
Detailed Programming Guide
1. User Settings
4
Operation Status Red Light Green Light Yellow Light Buzzer
Power on - Bright - Di
Stand by Bright - - -
Press keypad - - - Di
Operation successful - Bright - Di
Operation failed - - - DiDiDi
Enter into programming mode Bright - -
In the programming mode - - Bright Di
Exit from the programming mode Bright - - Di
Open the door - Bright - Di
Alarm Bright - - Alarm
To enter the programming mode * Master code #
999999 is the default factory master code
To exit from the programming mode *
Note that to undertake the following programming the master user must be logged in
To change the master code 0 New code New code# #
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
Entry is by card only
Entry is by card and PIN together
Entry is by either card or PIN (default)
3 0 #
3 1 #
3 2 #

5
To delete a PIN user 2 User ID number #
To change the PIN of a PIN user
(This step must be done out of
programming mode)
*
ID
number # Old PIN # New PIN #
New PIN #
To add a card user (Method 1)
This is the fastest way to enter cards,
user ID number auto generation.
To add a card user (Method 2)
This is the alternative way to enter cards
using User ID Allocation. In this method a
User ID is allocated to a card. Only one
user ID can be allocated to a single card.
To add a card user (Method 3)
Card number is the last 8 digits printed
on the back of the card,user ID number
auto generation
To add a card user (Method 4)
In this method a User ID is allocated to a
card number. Only one user ID can be
allocated to the card number
To delete a card user by card. Note users
can be deleted continuously without
exiting programming mode
To delete a card user by user ID. This
option can be used when a user has lost
their card
To delete a card user by card number.
This option can be used when the user
want to make the change but the card
has lost
Cards can be added continuous exiting programming
mode
1 Read card #
User can be added continuously without exiting
programming mode
1 ID number # Read card #
User can be added continuously without exiting
programming mode
Note users can be deleted continuously without
exiting programming mode
User can be added continuously without exiting
programming mode
1 Card number #
1 ID number. # Card number. #
2 Read Card #
To add a user in either card or PIN mode, i.e. in the mode. (Default setting)3 2 #
To add a Pin user 1 User ID number PIN# #
1 User ID no 1 PIN# # User ID no 2 #
PIN #
The ID number is any number between 1 & 2000.
The PIN is any four digits between 0000 & 9999
with the exception of 1234 which is reserved. Users
can be added continuously without exiting
programming mode as follows:
Users can be deleted continuously without exiting
programming mode
2 User ID #
2 Card number #

To Add a card and PIN user
(The PIN is any four digits between 0000
& 9999 with the exception of 1234 which
is reserved.)
To change a PIN in card and PIN mode
(Method 1) Note that this is done outside
programming mode so the user can
undertake this themselves
To change a PIN in card and PIN mode
(Method 2) Note that this is done outside
programming mode so the user can
undertake this themselves
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the
inside buzzer will beep automatically to remind people to close the door and continue for 1
minute before switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic
contact of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the
inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between
0-3 minutes with the default being 1 minute.
To delete a Card and PIN user just delete
the card
To set door relay strike time Master code # 4 0~99 # *
*
0-99 is to set the door relay time 0-99 seconds
Door Open Detection
6
To add a card and PIN user in card and PIN mode ( )
Add the card as for a card user
Press to exit from the programming mode
Then allocate the card a PIN as follows:
The operating is the same as adding and deleting a
card user in
*
*Read card 1234 # PIN # PIN #
*Read Card Old PIN # New PIN #
New PIN #
*ID number # New PIN #Old PIN #
New PIN #
2 User ID #
To Add and Delete a card user
2 0000 #
To unlock thedoor
For a PIN user Enter the PIN then press #
For a card User Read card
For a card and PIN user Read card then enter PIN #
1 #3
To add a card user in card mode ( )
0 #3
2 #3
To delete ALL users. Note that this is a
dangerous option so use with care
To delete All users
Relay Output Delay Time
2. Door Settings

The unit operating as a Wigeand Output Reader
In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be
connected to any controller which supports a Wiegand 26 bit input.
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN
numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm
and the inside buzzer will operate for 10 minutes, depending on the option selected below.
To disable door open detection. (Factory
default)
To set the alarm output time (0-3 minutes)
Factory default is 1 minute
7
6 0 #
To enable door open detection 6 1 #
Alarm output time
5 0~3 #
Normal status: No keypad lockout or
alarm (factory default)
7 0 # (Factory default setting)
Keypad Lockout 7 1 #
Alarm and inside buzzer operate 7 2 #
To remove the alarm
To reset the Door Forced Open warning Read valid card or Master Code #
To reset the Door Open Too Long warning Close the door or Read valid card or
Master Code #

Betriebsspannung DC 12V±10%
Benutzerkapazität 2000
Kartenlesedistanz 3-6 cm
Aktiver Strom <60mA
Leerlaufstrom 25±5 mA
Ausgangslast sperren Max 3A
Alarmausgangslast Max 20A
Betriebstemperatur -45℃~60℃
Betriebsfeuchtigkeit 10%- 90% RH
Wasserdicht Conforms to IP68
Einstellbare Türrelaiszeit 0 -99 seconds
Einstellbare Alarmzeit 0- 3 minutes
Wiegand-Schnittstelle Wiegand 26 bit
Verdrahtungsanschlüsse Electric Lock, Exit Button, External Alarm,External reader
8
Beschreibung
Das Gerät ist ein multifunktionaler Standalone-Access-Controller mit einer Tür oder ein
Wiegand-Ausgabetastenfeld oder Kartenleser. Es eignet sich für den Einbau in geschlossenen
Räumen oder im Freien in rauen Umgebungen. Es ist in einem starken, robusten und
vandalensicheren Zinklegierungs-Gehäuse untergebracht, das entweder in einem hellen Silber
oder Matt Silber-Finish erhältlich ist.Die Elektronik ist vollständig vergossen, daher ist das Gerät
wasserdicht und entspricht IP68.Dieses Gerät unterstützt bis zu 2000 Benutzer mit einer Karte,
einer 4-stelligen PIN oder einer Karte + PIN.Der eingebaute Kartenleser unterstützt 125KHZ
EM-Karten. Das Gerät verfügt über viele zusätzliche Funktionen wie Kurzschlussschutz, Wiegand
Ausgabe und eine Tastatur mit Hintergrundbeleuchtung.
Eigenschaften
• Wasserdicht, IP68-konform
• Gehäuse aus Zink-Aluminium-Legierung, Anti-Vandalismus-Gehäuse
• Komplette Programmierung über Tastatur
• 2000 verwendet, unterstützt Karte, PIN, Karte + PIN
• Kann als eigenständige Tastatur verwendet werden
• Hintergrundbeleuchtung Tasten
• Wiegand 26 Eingang zum Anschluss an externen Antrieb
• Wiegand 26 Ausgang zum Anschluss an einen Controller
• Türausstiegszeit, Alarmzeit, Türöffnungszeit können eingestellt werden
• Sehr geringer Stromverbrauch (30mA)
• Schnelle Betriebsgeschwindigkeit, <20ms mit 2000 Benutzern
• Sperren Sie den Ausgangsstromkurzschlussschutz
• Einfach zu installieren und zu programmieren
• Eingebauter light dependent resistor (LDR) für Anti-Tamper
• Habe den Summer
• Rote, gelbe und grüne LEDs zeigen den Arbeitsstatus an
Spezifikationen
Andere Handbücher für T-AC03
1
Inhaltsverzeichnis
Sprachen:
Andere Retekess IP-Zugriffskontrollsysteme Handbücher