RHEONIK RHE Series Bedienungsanleitung

installaon guide
RHE Coriolis transmier
Type RHE42
Version 02
Read the instrucons prior to performing any task!
© 2021

Rheonik Messtechnik GmbH
Rudolf-Diesel-Str. 5
85235 Odelzhausen
Telephone: + 49 8134 9341-0
Fax: + 49 8134 9341-41
Email: inf[email protected]
Internet: www.rheonik.com
Rev.: BA01RHE42202108
As at 08/21 – We reserve the right to make technical changes in the course of further development work

Foreword
3 / 109
RHE Coriolis transmier Type RHE42
Foreword
This installaon guide contains important informaon regarding how to install, start up, and safely operate the RHE42
Coriolis transmier as intended together with an RHM Coriolis sensor. The German version of the installaon guide is
the original installaon guide. It supplements the informaon provided in the RHE 40 desktop reference. The RHE 40
desktop reference and further informaon are available to download from the Rheonik Messtechnik GmbH website:
⮫
hps://rheonik.com
.
Copyright
This installaon guide is protected by copyright law. Any use that goes beyond the strict limits set by copyright law is
forbidden and liable for prosecuon without the prior consent of Rheonik Messtechnik GmbH. This also applies to any
reproducon, translaon and microlming in addion to saving and eding in electronic media. Any infringements will be
liable for compensaon!
Disclaimer
Rheonik Messtechnik GmbH accepts no liability for personal injury, damage to property or accidents caused by the
following:
■Failure to observe the installaon guide
■Failure to observe the safety regulaons
■Using the RHE42 Coriolis transmier in an impermissible manner
Liability
Claims for compensaon against Rheonik Messtechnik GmbH arising due to a breach of pre-contractual or contractual
obligaons or torous acts shall exist only in the case of intent or gross negligence on the part of the seller, their
representaves or vicarious agents.
If Rheonik Messtechnik GmbH breaches essenal contractual obligaons due to gross negligence, the extent of the
liability shall be restricted to the typically foreseeable loss. If performance is impossible or in the case of default, the
claims for compensaon shall be restricted to reimbursement of the typically foreseeable loss. If a vicarious agent of
Rheonik Messtechnik GmbH acts in a grossly negligent manner, Rheonik Messtechnik GmbH shall be liable to the extent
of the typically foreseeable loss. The liability in the case of a breach of essenal contractual obligaons and in the case
of fraudulent intent on the part of the seller remains unaected by this. In the case of physical injury or damage to
well-being and health, the applicable statutory regulaons shall apply.
Other applicable documents
The following documents contain addional informaon regarding how to operate the RHE42 Coriolis transmier:
■RHE 40 desktop reference (operaon manual)
■RHEComPro User Manual (operaon manual)
■RHE 40 HART Manual (operaon manual)
■RHE20/40 Addendum PID Controller (operaon manual)
■RHE40 Addendum Data Logging (operaon manual)
■RHE40 Addendum Precision Flow Analysis (operaon manual)
■RHE40 Addendum Stascs (operaon manual)
■RHE16/20/40 Modbus Map (list of Modbus registers)
■RHM Coriolis sensor (operaon manual)
The documents are available to download from the Rheonik Messtechnik GmbH website: ⮫
hp://rheonik.com
.

Foreword
4 / 109
RHE Coriolis transmier Type RHE42

Table of contents
5 / 109
RHE Coriolis transmier Type RHE42
Table of contents
1 About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1 General informaon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.2 Target group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 Declaraon of Conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5 Symbols used in this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1 How warnings are structured and what they mean. . . . . . . . . . . 10
2.2 Safety and associated safety measures. . . . . . . . . . . . . . . . . . . . . 11
2.3 Personnel qualicaons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1 Impermissible use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4 Product descripon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1 Model code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2 Protecon classes and safety areas (explosion protecon). . . . . 20
5Transportaon, storage, scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . 21
6 Installing the RHE42 Coriolis transmier. . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.1 Installing the RHE42 Coriolis transmier onto a wall or
mounng plate (RHE42-R*). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.2 Installing the RHE42 Coriolis transmier on a pipe (RHE42-R*). 25
7Connecng the RHE42 Coriolis transmier. . . . . . . . . . . . . . . . . . . . . . . . 26
7.1 Connecng the RHE42 Coriolis transmier to the RHM Coriolis
sensor (RHE42-R*). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.2 Connecng the power supply, inputs/outputs and signal cables
to on the RHE42 Coriolis transmier. . . . . . . . . . . . . . . . . . . . . . . 31
7.3 Wiring diagrams for the power supply, RS485 and Modbus TCP. 37
7.3.1 Connecng the power supply. . . . . . . . . . . . . . . . . . . . . . . . . . 37
7.3.2 Connecng the RS485 interface. . . . . . . . . . . . . . . . . . . . . . . . 37
7.3.3 Connecng the Modbus TCP interface. . . . . . . . . . . . . . . . . . . 39
7.3.4 Connecng the Foundaon Fieldbus / Probus interface. . . . 39
7.4 Wiring diagrams for non-intrinsically safe inputs and outputs. . 41
7.4.1 Connecng non-intrinsically safe analogue outputs. . . . . . . . 41
7.4.2 Connecng non-intrinsically safe digital outputs. . . . . . . . . . . 42
7.4.3 Connecng non-intrinsically safe digital inputs. . . . . . . . . . . . 43
7.4.4 Connecng a non-intrinsically safe HART interface. . . . . . . . . 44
7.5 Wiring diagrams for intrinsically safe inputs and outputs. . . . . . 45
7.5.1 Connecng intrinsically safe analogue outputs. . . . . . . . . . . . 45
7.5.2 Connecng intrinsically safe digital outputs. . . . . . . . . . . . . . . 45
7.5.3 Connecng intrinsically safe digital inputs. . . . . . . . . . . . . . . . 46
7.5.4 Connecng an intrinsically safe HART interface. . . . . . . . . . . . 47

Table of contents
6 / 109
RHE Coriolis transmier Type RHE42
8 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.1 Funcon of the keys on the RHE42 Coriolis transmier. . . . . . . . 49
8.2 Operaon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.3 Inial start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
8.3.1 Calibrang the zero point. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
8.3.2 Changing the ow direcon. . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8.3.3 Reading out the IP address. . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.3.4 Seng up the RS485 interface. . . . . . . . . . . . . . . . . . . . . . . . . 58
8.3.5 Seng the units of measurement. . . . . . . . . . . . . . . . . . . . . . . 60
8.3.6 Conguring analogue outputs. . . . . . . . . . . . . . . . . . . . . . . . . . 62
8.3.7 Conguring digital outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
8.3.8 Conguring digital inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
8.3.9 Performing an output test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
9Operaon, operang modes, using the device. . . . . . . . . . . . . . . . . . . . . 75
9.1 Reseng the mass ow and volume meters. . . . . . . . . . . . . . . . 75
9.2 Adjusng the display sengs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
9.3 Seng the lter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
10 Servicing, maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
10.1 Reading out the Assurance Factor and displaying the Assurance
View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
10.2 Reading out the zero point. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
11 Displaying errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
12 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
13 Returns and disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
14 Appendix A: Ex-Safety Instrucons (product approval informaon). . . . 95
15 Appendices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

About this guide
7 / 109
RHE Coriolis transmier Type RHE42
1 About this guide
1.1 General informaon
This installaon guide contains important informaon regarding how to install,
start up, and safely operate the RHE42 Coriolis transmier as intended. Care-
fully read the informaon in this installaon guide before starng any work
with or on the RHE42 Coriolis transmier, and make sure you have understood
everything.
1. Please familiarise yourself with the informaon in this installaon guide.
2. Observe the safety instrucons and warnings in this installaon guide.
1.2 Target group
This installaon guide is aimed at operang personnel and at anyone who has
been tasked with the installaon and start-up work by the operang personnel.
1.3 Storage
This installaon guide is an essenal part of the RHE42 Coriolis transmier and
must be stored such that it remains accessible to personnel at all mes.
1.4 Declaraon of Conformity
The versions of the RHE42 Coriolis transmier described in this installaon
guide comply with the applicable standards and guidelines/direcves.
The manufacturer’s Declaraon of Conformity can be found in the appendix to
this installaon guide.

About this guide
8 / 109
RHE Coriolis transmier Type RHE42
1.5 Symbols used in this guide
In this installaon guide, secons containing parcularly important informaon
are idened in line with the type of informaon they contain, e.g. instrucons,
lists or references.
Symbol Meaning
Instrucon; step in a process
If you need to perform several steps one aer the other, they
will be numbered based on their chronological sequence.
Instrucons that consist solely of a single step are not num-
bered.
Result; outcome of a step
Lists of entries in no parcular order
References to gures, secons and chapters
This symbol indicates useful addional informaon.

Safety
9 / 109
RHE Coriolis transmier Type RHE42
2 Safety
To ensure that the RHE42 Coriolis transmier is operated safely and as
intended, it is essenal to familiarise yourself with the basic safety instrucons
and safety regulaons. It is also essenal to comply with the rules and regula-
ons on accident prevenon that apply at the installaon locaon.
This installaon guide contains important informaon regarding how to safely
operate the RHE42 Coriolis transmier as intended. Carefully read the informa-
on in this installaon guide before starng any work with or on the RHE42
Coriolis transmier, and make sure you have understood everything.

Safety
10 / 109
RHE Coriolis transmier Type RHE42
DANGER: Hazard with a high risk and
that will result in death or serious
injury if not prevented.
WARNING: Hazard with a moderate
risk and that may result in death or
serious injury if not prevented.
CAUTION: Hazard with a low risk and
that may result in slight or moderate
injury if not prevented.
ATTENTION (NOTE): Risk of damage
to property if informaon is not
observed.
2.1 How warnings are structured and what they mean
When performing dierent types of work either with the or on the RHE42
Coriolis transmier, the personnel carry out steps that could entail hazards.
These steps are therefore preceded by a warning.
Warnings are always structured as follows:
■Warning symbol
■Signal word:
–DANGER
–WARNING
–CAUTION
–ATTENTION
■Descripon of the type of hazard and how it arises
■Descripon of the potenal consequences of disregarding the hazard
■Descripon of measures for prevenng the hazard
DANGER
Type of hazard and how it arises!
Potenal consequence(s) of disregarding the hazard.
−List of measures for prevenng the hazard
WARNING
Type of hazard and how it arises!
Potenal consequence(s) of disregarding the hazard.
−List of measures for prevenng the hazard
CAUTION
Type of hazard and how it arises!
Potenal consequence(s) of disregarding the hazard.
−List of measures for prevenng the hazard
NOTICE
Type of hazard and how it arises!
Potenal consequence(s) of disregarding the hazard.
−List of measures for prevenng the hazard
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere RHEONIK Sender Handbücher
Beliebte Sender Handbücher anderer Marken

Dejero
Dejero EnGo 3x Bedienungsanleitung

Rosemount
Rosemount 4600 Bedienungsanleitung

Speaka Professional
Speaka Professional 2342740 Bedienungsanleitung

trubomat
trubomat GAB 1000 Bedienungsanleitung

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Bedienungsanleitung

Rondish
Rondish UT-11 Bedienungsanleitung