Roma Heating CT1000 Bedienungsanleitung

WiFi Colour Touch Screen Thermostat
V0122

Roma WiFi Colour Touch Screen Thermostat
• The colour touch screen thermostat is designed for electric
floor heating or water heating systems. Equipped with the latest
4.3 inch colour touch LCD display, the thermostat can be easily
operated and understood. The thermostat is fully programmable
to automate your heating, can be used in a simple manual
mode or controlled remotely on a phone or tablet using the Smart
Life APP.
• With five modes, these instructions will explain how to set your
system to work in accordance with your lifestyle. This is done by
pre-setting your preferred temperatures into the 7 days easy
programmable function.
• Simple regulation with advanced programming sends commands
to the heating system according to a pre-selected temperature
variation. The thermostat control algorithm also includes an
anticipation function which reduces the discrepancy between the
thermostat reading and the temperature at the centre of the room.
This helps save energy and make for a more even and comfortable
room temperature.
• Choose from multiple sensor settings: Air temperature, Floor
temperature and ambient (a combination of both air and floor
sensors working together). Air temp is controlled through the built-in air
temperature sensor and floor is controlled via the included external
floor probe.

Thermostat Features
• Advanced 4.3 inch Colour Touch Screen Operation
• Adjustable Screen Brightness For On And Sleep Modes
• Electric Heating System ( Max. 16A) or Water Heating
System Max.3A)
• WiFi control with Smart Life APP.
• Adjustable Comfort Mode, Economy Mode, Party Mode, Holiday
Mode and Automatic Programme Mode Control
• 7 Days Programmable settings
• External and Internal Sensors
• Clock and Day Display
• Temperature Calibration
• Temperature Protection
• Fits Standard 1G Deep Back Box
Technical Data
• Voltage: 230V, 50/60Hz
• Load: 16A Max)
• Temp.Setting Range: 5 - 45 °C
• Ambient :0 - 50°c
• Sensor: NTCIOK. 3950ohms at 25°c
• Accuracy: - 0.5 °c
• Protection Class : IP30
Back mm
Side mm
Front mm

Home Screen
Menu Screen
Mode Screen
Screen and Display
1239
8 6
5
4
12
13 14 15
19 20
21 22 23 24 25
16 17 18
10
7
11

l ON/OFF Use to turn thermostat on/off
2 Mode Button Use to select working mode
3 Menu Button Use to select menu settings
4 Down Button Down button
5 Up Button Up button
6 Wi-Fi Wi-Fi connect button
7 Unregulated Temp Shows 2nd temp not being regulated
8 Regulated Temp Shows primary temp being regulated
9 Set Temp Shows set temp (Range 5-45°C)
10 Selected Mode Show current working mode
11 Time / Day Current time & day of week
12 Floor Heating Up When on power is going to heating
13 Out Of Limit Warning On if floor temp over protection limit
14 Lock On when screen is locked
15 Wi-Fi Button Use to set up Wi-Fi & Connect to APP
16 Date & Time Set Weekday and Time
17 My Schedule Set up automated heating schedule
18 Pre-Set Modes Set 4 x Pre-set working temps / modes
19 Language Select language (EL Units Only)
20 Hi / Low Protection Set Max/Min Floor Temperatures
21 Comfort Mode Run Pre-set mode 1 = comfort
22 Economy Mode Run Pre-set mode 2 = economy
23 Party Mode Run Pre-set mode 3 = party
24 Holiday Mode Run Pre-set mode 4 = holiday
25 My Schedule Run My auto 7 day schedule
Home Screen
Menu Screen
Mode Screen

Press Menu button, then press
You can then review your automated
schedule. Touch any column to
select it and make changes where
necessary or press >> bottom right
to move on to next 3 days.
To make changes to a selected
column, use the green and
on the left to select different zones
for that day / column. Once the
desired time zone is selected
use the green and on the
right hand side to set the time and
temperature for the selected zone.
The time for each zone should be set in consecutive times
throughout the day i.e. 7am – 8am – 9am – 14.30pm etc. The time
must not skip foward then backward as you work down the time
zones for each column. Once you have made changes press
‘APPLY’ to save changes. Then click cancel go back and select
another day / column or cancel again to bring up the home
screen. Once set the time and temperature in each zone will be held
by the thermostat until the next time zone starts.
My Schedule Setting
The schedule can be set up directly on the thermostat using the
touch screen, (see below) or remotely using WI-FI and the Smartlife
APP. Please follow on screen instructions when using the APP.
NOTE: Must be selected for thermostat to run the auto schedule.

Edit Date and Time
Press Menu button, then press
you can now edit date & time with
or buttons. Once set simply
press" APPLY" to save the changes.
Pre-set Mode Temperatures
Press Menu button, then press
You can now pre-set the 4 different
mode temperatures. = Comfort,
= Holiday, = Party, = Economy.
By pre-setting the temperature of
each mode they can be selected quick and easily. The thermostat
will then hold the setting until another mode or temperature is set.
Max / Min Temp Protection
Press Menu and then press . You
can now set your maximum and
minimum floor temperatures. These
limits will turn the heating on or off
should the floor probe temperature
exceed these settings. NOTE: Only Low Protection will show if only
air or floor sensor is being used. Both Air and Floor sensors need
to be in operation for High Protection to show and be editable.
Also these setting should be used in conjunction with “Set Point
Max” and “Set Point Min” settings, see settings page 1 for more
information on these settings.

Settings Pages.
Depending upon how you use your thermostat and the type of
heating system installed you may need to adjust the internal default
settings on this thermostat. To access these settings,
1: Make sure the unit is in the ON position.
2: Press OFF in bottom right hand corner.
3: Confirm off by pressing OK in centre of screen.
4: Within 2 seconds press and hold on Time / Day top left hand
corner of the screen for 5 seconds. NOTE: You need to press and
hold on VERY top of screen where Time and Day is.
Temperature Offset / Calibration.
This allows the temperature to be
calibrated should the temperature
displayed on the screen not be true
to the actual air / floor temperature.
Dead Zone. This is the number of degrees above & below the set
temperature the regulated temperature will be permitted to go
before turning the heating off or on to keep the regulated
temperature within these limits. We suggest setting this to 1.5
especially in quiet areas.
Set Point Max / Min, (Also see MENU setting ). This is the
Maximum & Minimum temperatures the thermostat can be set to.
NOTE: A yellow triangle will appear on screen if the regulated
temperature on screen ever passes these set points.
Settings Page 1.

This setting alows the user to select
between air, floor or a combination
of air & floor sensors.
I = Internal Air Sensor Temp.
E = External Floor Probe Temp.
I&E = The thermostat will only regualte air temp but will show all 3
temperatures. If however the floor temp exceeds the high or low
temperature protection settings the heating will turn off or on
until the floor temperature no longer exceed these settings. During
this time a Yellow warning triangle will appear on screen.
IorE = Only floor temperature will be regulated and shown along with
set temp. If however the air temp drops below the Low Protection
setting then the heating will turn on.
Setting Page 3: EL Units Only.
Backlight Time. This is the time
the screen is fully illuminated before
turning down in brightness.
Backlight Min.is the % of maximum
brightness the screen will show
when not in use. Backlight Max is the % of maximum brightness
the screen will show when in use. Backlight On/Off. Backlight can
be set to full off when screen is not in use. NOTE: A low backlight
or full off is best for bedrooms.
Settings Page 2, NTC Select.
Settings Page 4, Backlighting.

Relay Out Delay. The time in seconds
delay between switching the heating
on or off once the temp reaches or
falls below the set temp.
Relay Out. This changes the
switching of the relay between normal & inverted. Electric heating
should be run on Normal. When controling water systems please
refer to the systems specifications for clarification.
Auto Lock. Set to Enable to lock
screen automatically after 60
seconds of screen inactivity to
prevent unwanted setting changes
or tampering. To unlock the screen,
touch any button once and then within 2 seconds press and hold
the Time / Day on the top left hand corner for 10 seconds, (hold
VERY top of screen on Time / Day). The lock will then deactivate
for a short period of time before relocking. Delay Time.
Restore to factory defaults. This
allows the user to reset the unit to
the original default settings.
Settings Page 5, Relay.
Settings Page 6, Lock.
Settings Page 7, Restore.
Andere Handbücher für CT1000
2
Andere Roma Heating Thermostat Handbücher

Roma Heating
Roma Heating TR3 Bedienungsanleitung

Roma Heating
Roma Heating RW800i Bedienungsanleitung

Roma Heating
Roma Heating TS700 Bedienungsanleitung

Roma Heating
Roma Heating RWI5 Bedienungsanleitung

Roma Heating
Roma Heating RT5 Bedienungsanleitung

Roma Heating
Roma Heating CT1000 Bedienungsanleitung

Roma Heating
Roma Heating CT1000 Bedienungsanleitung
Beliebte Thermostat Handbücher anderer Marken

EWELLY
EWELLY EW-181 Bedienungsanleitung

Prolon
Prolon T1100 Montageanleitung

Computherm
Computherm Q20 Bedienungsanleitung

Heatmiser
Heatmiser neoStat Bedienungsanleitung

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Bedienungsanleitung

Mars