Rutenbeck Control IP 4 Bedienungsanleitung

Control IP 4
Operating instructions GB
Technical Support
+ 49 2355 82-111
Commercial Support
+49 2355 82-137

2 Device overview
Device overview
Buttons for manual switching
LED for activity
To the 230 V power supply
Network connection
Temperature sensor
connection
LED for link
External buttons
(for manual switching)
Switch outputs

General information 3
Electrical devices can be
switched via a TCP/IP network
with the Control IP 4. The
device is stored in a series
mounting case.
The Control IP 4 outputs can
be switched via web browser
from all computers on the same
network by accessing the IP
address 192.168.0.3.
The switch outputs can be
operated using integrated or
installed buttons on the device.
The current switching state of
an output is displayed via an
LED on the associated switch
button. The Control IP 4 is
equipped with an integrated
time switch function. Five
switch-on or switch-off times
can be individually selected for
each switch output.
The Control IP 4 automatically
obtains the time required for
the switch functions from the
europe.pool.info.org server
using the Simple Network Time
Protocol (SNTP) and, providing
that the server can be reached,
is then compared each hour.
The current temperature can be
displayed (providing that a tem-
perature sensor is connected),
the network properties and the
timer switch can be set via the
web browser.
Alternatively, the Control IP 4
can be operated via the Internet
or a Smartphone if a fixed IP
address or the translation of the
dynamic IP address is present
in a host name.
The Control IP 4 can be con-
trolled directly via UDP. Two lan-
guages can be selected for the
settings (German/English).
General information

4 Installation
The free app ‘Rutenbeck-
Remote’, available from
Apple’s App Store, allows
remote control of the device
via Apple smartphone or tablet.
Attention: Work to
the power supply net-
work may only be per-
formed by authorised
electricians.
Risk to life from
electric current!
Ensure that the power
supply is disconnected
before performing any
assembly work.
Please observe the permissible
operating temperature, do not
use the Control IP 4 directly
next to devices that generate
a high amount of heat (e. g.
dimmer).
Ensure that the device is only
used indoors.
Installation
InstallationNotice

Settings 5
Network settings without DHCP server
Settings
Figure 1
F
A B C D E

6 Settings
1. Connect the Control IP 4 to
the local network using a
patch cable (available
separately).
2. If necessary, connect the
temperature sensor to the
two terminals.
3. Connect the Control IP 4 to
the 230 V mains voltage.
4. The Control IP 4 can
now be accessed via the
address http://192.168.0.3
or http://TCRIP4 (factory
setting).
5. Select the “Network” menu
in the menu bar (Fig. 1, A).
6. Select an individual “Net-
work name” in order to be
able to call up the Control
IP 4 directly.
7. Modify the IP-address of
the Control IP 4 to suit your
own needs.
8. The configuration is stored
by pressing “Save”.
Network settings without DHCP server
Settings

Settings 7
1. Connect the Control IP 4
to the local network using
a patch cable (available
separately).
2. If necessary, connect the
temperature sensor to the
two terminals.
3. Connect the Control IP 4 to
the 230 V mains voltage.
4. The Control IP 4 can
now be accessed via the
address http://192.168.0.3
or http://TCRIP4 (factory
setting).
5. Select the “Network” menu
in the menu bar (Fig. 1, A).
6. Select an individual “Net-
work name” in order to be
able to call up the Control
IP 4 directly.
7. Now activate the DHCP
client (Fig. 1, B).
8. A free IP-address is now
assigned to the Control
IP 4.
Network settings with DHCP server
Settings

8 Settings
Configuration
Settings
HI
Figure 2
G

Settings 9
Increase the access security
to the Control IP 4 by setting
an individual user name and
a password in the “Settings”
menu. (Fig. 2, G).
As soon as you issue a pass-
word, the user name and the
password will be queried prior
to accessing the Control IP 4.
The user will remain logged on
until the browser is closed.
Three access security setting
categories are available:
1. No Administrator name,
no User name: Everybody
has full access to all func-
tions.
2. Only Administrator name:
Everybody has access
to the website, is able to
switch manually and oper-
ate the timer switch. Only
the “admin” is able to per-
form network settings and
configuration.
3. Administrator name and
User name: “user” and
“admin” have access to
the website and are able to
switch manually. However,
the network settings, the
timer switch settings and
the configuration can only
be performed by “admin”.
You can give the four outputs
individual names. These names
will then be displayed in the
menu bar.
If you wish, you can switch the
automatic time synchronisation
function (H) on.
In order to do so, you must
enter the “Gateway” (Fig. 1, D)
and “DNS server” (Fig. 1, E)
information in the “Network”
menu.
The configuration is stored by
pressing “Save”.
Configuration
Settings

10 Settings
Factory settings
You can replace the Control
IP4 factory settings with your
own settings.
Proceed as follows to restore
the factory settings:
1. Disconnect the Control IP 4
from the 230 V mains
voltage.
2. Simultaneously press but-
tons 1 and 2 on the device
and re-connect the mains
voltage whilst holding the
buttons.
3. The LEDs for the outputs
flash after three seconds
and the factory settings are
loaded.
Settings
Buttons
Operating elements
LEDs
The Control IP 4 outputs can
be switched via the buttons
located directly on the device,
the installed buttons or via the
Control IP 4 website.
1-4: Switches the connected
device on/off; restores the
factory settings (see above)
1-4: Switching state of the
device (illuminated when
switched on)
Link: Link state (illuminated in
the event of a network
connection)
Act: Activity (flashes when the
Control IP 4 web interface
is being called up)