SalonTech PediJoy Bedienungsanleitung

Whirlpool Pedicure Spa
Manual
Pedi

Important requirements
Requires that you contact your local, licensed plumber and licensed electrician to install your new spa. Installation
MUST be in compliance with all local and state building codes. Your pedicure spa can not operate efficiently or safely unless it is
provided with adequate electrical power, sufficient water pressure, proper water temperature, and required drainage capabilities.
Contact your local building inspector for information and local code compliance procedure that need to be followed when having your
new pedicure spa installed. Subsequent inspections and approvals that may be required are the responsibility of the purchaser.
Thank you for choosing , the leading manufacturer well known worldwide for its innovation and design in
pedicure spas. takes pride in bringing you quality products that meet today’s demand for safety and service.
The Whirlpool Pedicure Spa has been designed for dependability, and to benefit all with a health conscious
clientele.
Precaution
- Do not stand in the basin of the spa.
- Excessive water temperature is dangerous and should be checked before use. Maximum water Temperature should not exceed
150F (65C).
- Always enter and exit the spa slowly and carefully.
- Never bring or operate any electrical device near pedicure spa.
- The unit has a weight capacity of 250 pounds.
Health Warning
Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use the pedicure spa at any time. The
technician should advise clients to consult their physician before using the spa if there is any sign of fungal infection, swelling,
fracture, or persistent pain. In some cases diabetics may experience improved circulation in their feet, but should first consult their
physician prior to receiving a pedicure.
If the client experiences any pain or discomfort, discontinue the use of the pedicure spa
immediately.
Shipment Inspection
Examine the components immediately upon arrival to make sure no damages to the pedicure spa base and chair during the shipment. It
is very important that you notify the driver directly on the face of the freight bill or bill of lading of any damage. Failure to note
damage on the bill of lading may prevent any claims you may have against the carrier.
If concealed or damage is found, you MUST notify the carrier at once and request an inspection. You do so at your own risk and
expense. DO NOT DISCARD THE SHIPPING CARTON until you give the carrier a clear receipt of goods that have been
damaged in transit.
PLEASE TAKE TIME TO READ THIS MANUAL THOROUGHLY BEFORE USE. If you have any questions or
problems with your pedicure spa, please contact our Customer Service and Technical support at 516-484-4937, Monday
thru Friday 9AM - 5PM, or email us at [email protected]
Pedi

53”
29”
Whirlpool Pedicure Spa
Salontech LLC
57 Seaview Blvd.
Port Washington, NY 11050
Tel: 516-484-4937
Fax: 516-484-4938
www.salontech.com
info@salontech.com
Serial Number:
Order Number:
Installed by:
Installation date:
Chair Serial Number
IMPORTANT INFORMATION
Pedi

Important Considerations
Electrical Service
A 110V, 60 Hz, 15 Amp GFCI protected grounded circuit must be used to supply power to each individual pedicure spa.
Water Supply
All plumbing connections must conform to local codes.
Water supply to the spa should be provided with adequate water pressure and water temperature.
Water pressure
To fill the basin correctly up to level, Normal water pressure of 30 to 80 P.S.I is required.
Water temperature
The hot water supply temperature must not exceed 140 . Adjust your hot water accordingly. For hot and cold water supply
fittings and drain fittings location, see below diagram .Carefully connect the water supply line to the appropriate fittings
located on the rear of the pedicure spa.
Back flow Preventive Device
All pedicure spas are pre-installed with Dual Back flow Preventive Device for the following state; CA, AZ, NV, OR, WA, and
NE
Hot Water
Supply
Inlet
Cold Water
Supply
Inlet
1-1/2” PVC Drain
Outlet
ALL Fittings are ½”NPS (Male)
Back of the pedicure spa
The pedicure spa Drain must meet local plumbing codes. Check valve for Drain (not Provided) Must be installed by a licensed
plumber.
PLUMBING CONNECTIONS
Specification
Back flow preventive device for faucet: Vacuum Breaker comply with ANSI/NSF - 61-2000, ASMB A112.18.1-2000, ASSE
1014 and CSA standard - B125.98.
Drain Facilities
ANSI/ASME A112.18.3M (performance requirements for back flow preventive device and systems in pluming fixture fittings)
is applicable to plumbing fixture fittings with outlets not protected by an air gap. Included in the possible range of applications
are fittings with hose connected outlets, fitting with pull out spout, hand held showers, shampoo fittings and deck mounted
fittings. ASME A112.18.3M is now referenced in ASME A112.18.1M (plumbing fixture fittings) and CSA B125. Back flow
preventive devices are listed to both standards with the canadien standard association, IAPMO and UL.
ANSI - American National Institute, ASME - American Society of Mechanical Engineers, CSA - Canadian Standard
Association IAPMO - International Association of Plumbing and Mechanical Officials, UL - Underwriters Laboratory

Caution
Warranty will be null and void.
Please DO NOT lift or move the Spa with faucet handle

Components
Due to continuous improvements on all our products, specification, characteristics, packing, color, designs re subject to change without notice
Identifying components
1 - AUTO SLIDER REMOTE CONTROL (AUTOMATIC SLIDER)
2 - CLEAN PIPELESS JET / CLEAN JET COVER
3 - SHOWER SPRAYER
4- SHOWER STAND
5 - DRAIN PLUG
6 - OVERHEAD WASTE KNOB
7 - ADJUSTABLE FOOTREST
8 - FAUCET
9 - ON/OFF WHIRLPOOL AIR ACTIVATE BUTTON
10 - MANUAL SLIDER LEVER (MANUAL SLIDER)
11 - MASSAGE MAIN ON/OFF SWITCH
12 - MASSAGE AND BUILT IN RECLINER REMOTE CONTROL
13 - BACKREST
14 - HEAD PILLOW
15 - FUSE FOR MASSAGE SYSTEM
16- I-JOY CHAIR SERIAL NUMBER
17- LED LIGHT SYSTEM
ON
OFF
Pedi
1
2
6
15
14
13
12
11
10
9
8
7
5
6
16
17
4
3
stop
power
position
partial
percussion
compression
kneading
rolling
lower
upper
full
2
3
5

Dual Clean Pipeless System
with Adjustable air control system for powerful whirlpool action
Dimension & Weight
Capacity of Tub
Switch
Whirlpool
Power Source
Plumbing Source
Warranty
Pedi-Joy (Base unit)
Pedi-Joy (Chair)
Stool
Clean Jet
Air Control
Motor
Discharge Pump (optional)
Massage System
Hot Water
Cold Water
Drain
Unit
Optional Item
58”L x 32”W x 21”H Shipping Wt.130 Lbs
52”L x 32”W x 21”H Shipping Wt. 115 Lbs.
20”L x 12”W x 17”H Shipping Wt. 18 Lbs
4.25 US Gallon
On/off Air Activate switch
Hydro therapeutic clean pipeless system with
dual directional flow system
Air induction system
115V 1.25 Amp
115V. 3.2 Amp. 60Hz
110V-120V 60Hz 90W 5Amp
½ inch (fitting pre-installed)
½ inch (fitting pre-installed)
1-1/2 inch ( see plumbing instruction)
One Year ( see warranty)
180 days
Specification ( PipeLess Clean Jet System)
Specification ( PipeLess Clean Jet System)
14
Due to continuous improvements on all our products, specification, characteristics, packing, color, designs are subject to
change without notice.
Pedi
P-tr ap and 1 -1 /2” exten sion PVC pipe

Salontech,LLC Pedi-Joy
Salontech,LLC
Top / Rear view
Pedi
Wall
2-3/4”
3”
10”
2”
Plumbing Fitting
15”
42”
38”
29”
27”
26”
Plumbing connection
area
Drain Pipe extension
Center of drain to end of drain pipe
Required space
for installation
54”

Installation Specifications Summary
Warning: Failure to comply with federal, state or local codes and ordinances will result in warranty being null and void.
As stated, the pedicure spa installation must comply with all plumbing and electrical codes. A licensed plumber and
licensed electrician must complete the applicable connections of the pedicure spa.
Location and support
Select a level location. The floor structure beneath the pedicure spa must be capable of supporting the occupied pedicure
spa.
For the seat back to fully recline, the pedicure spa base must be mounted 15 inches from the wall as shown below:
15”
How to use adjustable footrest
Place left hand on the back of the footrest and gently
pull up toward to front as shown Fig.2
Fig 2.
Fig 1.
And place right hand on the front of the footrest,
gently pull up for desirable height and use locking
lever to secure the footrest.
Due to continuous improvements on all our products, specification, characteristics, packing, color, designs are subject to
change without notice.
Wall

Note:
The requirement for the vacuum breaker varies
from state to state and province to province,
Please consult with the licensed plumber.
Pedi
Wall Drain
Floor Drain
Power Drain
Manufacturer installation recommended
Note: Plumber must utilize hot & cold water valves
Pedi ½”Hot&Cold
water inlet
21”
2-3/4” 37-1/2”
41-1/2”
15”
46-1/2”
Pedi ½”Hot&Cold
water inlet
15”
46-1/2”
41-1/2”
37-1/2”
2-3/4”
21”
Pedi ½”Hot&Cold
water inlet
½”Discharge
outlet
3/4”
inlet
1” Extension Pipe
21”
2-3/4” 37-1/2” 15”
46-1/2”
Andere SalonTech Pediküre Spa Handbücher