TEC1ACLSeriesQuickStartKeypadProgrammingandInstallationGuide
Rev 01/21
Rev A
ThisQuickStartGuideAppliesto:
TEC1ACL2L/4LSeries
Thisexampleshowshowtosetadirectoryrecord(Code,Name,Phone#
andPINforentrance1with24/7access)usingthekeypad.TosetaPIN,the
ENABLEPINSparametermustbesetto1(seestep2below).Forother
settingspleasereferto“TEC1ACLSeriesMenus”
1) ENTERPROGRAMMINGMODEtoaccesstheCODES&NAMESmenu:
• Press*0togethertodisplay“Password”.
• Enter6‐digitpasswordfollowedby*(factorydefaultis777777*)
Thisdisplays“MAINMENU/SELECT1‐8”.
• Press1todisplay“CODES&NAMES,SELECT1‐9”
2) SkipthisstepifyouknowPINsareenabled.Press8todisplay“ENABLE
PINS=X”.IfXis1press*;ifXis0thenpress1*.
3) ProgramadirectoryrecordtoincludeaPIN:
• FromCodesandNames,press1toselect“AddNew”todisplay“CODE=”
• Enteracodefollowedby*e.g.“100*”.Displaywillnowshow“NAME=”
• Enteraname.ForNAMESonly,aftereachcharacter,press#tomove
cursore.g.J#O#H#N#willspell“JOHN”.Tocompletethename,press*.
Displaywillnowshow“PHONE#=”
• Enterphonenumbere.g.3055551212,then*todisplay“PIN=”
• Enter4‐digitPINe.g.1234then*todisplay“ENTRANCE=0”
• Tosetentrance1Press1*todisplay“TGGROUP=0”
• TosetTimeGroup0Press0*(TG0is24/7)toshow“CODE=”fornext
entry.Ifnootherentriesareneeded,exitprogrammingmode.
4) EXITPROGRAMMINGMODE:
Press*0together===>TEC1ACLwelcomemessagewillbedisplayed.
AdditionalInformation:
WhenProgrammingwithSelcomSoftware,choosefirmware/model
selectionasTEC1ACL2.5andup.
QuickStartInstallationGuide(SeeTEC1ACLInstallerGuideforSafety
Warnings)
● Power:DONOTUSEACTRANSFORMER.A12VDC/2Apowersupplyis
suppliedandshouldbewiredtoDCinputmarkedonthebackboxterminal
block.InternalpowerconnectionfromtheterminalblocktoP1connectoron
PCBisfactoryinstalled.Ifinstallerchooses,athisownrisk,nottousethe
powersupplyprovided,warrantyisvoided.
● Ground:TheTEC1ACLGroundStudMUSTbeconnectedusingaminimum
#16ga.strandedwireconnectedtoagoodearthgroundusinge.g.aground
rodorcoldwaterpipe.Themaximumgroundwirelengthis50feet.Ifan
adequateearthgroundisnotprovided,surgedamageprotectionbuiltinto
TEC1ACLseriesunitsdiminishesandvoidsthewarranty.
● Telephone:RJ‐11plugandcablefordial‐outphonefromCellularInterface
Module(Factoryinstalled).ConnecttoTE‐TEonP1.
● Relays:Two(2)relayswithboth(N/O)and(N/C).Maximumratingeach
contact24voltsAC/DCat2A.ConnectusingNC/COM/NONC/COM/NOonP1A
●Rex(RequesttoExit)Inputs:TheRX1andRX2areVOLT‐FREE(dry)contacts.
ConnectusingRX1‐COM‐RX2onP1.