Configuring an MRU network
0311355 Issue : January 2002
2-3
• Configuration procedure
Now that your MRU is connected to a PC as indicated in the previous
paragraph, do the following :
- Insert the diskette into drive A
- Select the A drive
- Type in one of the following commands depending on whether the
attached MRU is intended to be used at the central or monitoring station
(« base »MRU) or in a mobile (mobile MRU).
base<sp>[channum]<sp>camp{<sp>master}Base MRU
(monitoring station)
base<sp>[channum]<sp>lab{<sp>master}Base MRU
(central station)
mobile<sp>[channum]<sp>[regnum]<sp>[refresh rate]Mobile MRU
Where :
[channum]: UHF frequency channel number (0 to 5600,
depending on the country ; 4000 to 5600 for the
USA)
[regnum]: Mobile registration number (1 to 50)
[refresh rate]: (10, 30 or 60 seconds)
{master}: Optional parameter, configures a MASTER MRU as
sync master. A single MRU should be defined as
the sync master.
Conventions used in the syntax above :
[..]: Square brackets enclose parameter definition which
should be replaced by the desired value in the
command line
{...}: Braces enclose optional parameter
<sp> : Space character required
Square brackets and braces should not be typed in
the command line.
Getting help from the setup program :
Simply type in base or mobile to display the
syntax of the commands, as described above.