1 0 MA03/1 Datum 08.01.2002 Art.Nr. 79474 Z.Nr. 8664074 Änd.Stand 389/01
rencepoint of the measuring
system. This value is set by
referencingthesystemaccording
to chapter 8.
_oFF_ Offset: Can be any value; used to
influence the value displayed, eg.
toolcorrection value.
_dP_ Decimal point (only available if
'Resolution'hasbeenprogrammed
to'FrEE'before):Determinationof
the decimal point according to the
resolution.
_dIr_ Countingdirectionofthemeasu-
ring system: depends on the
sensor’smountingposition and
canbechanged subsequently.
"UP" Upward
"dn" Downward
_AUto_ Switch-off method: State of the
automatic switch-off:
"oFF" no switch-off.
"on" automatically switch-off
PErIod Switch-off time : Time since last
measurement / sensor move after
which the display will switch-off.
_rSto__ Last value memory:
"oFF" Last value memory off. When
switched on, the display must be
calibrated(zeroed).
"on" Last value memory on. When
switched on, the last measured
value is displayed.
_4_oFF Delayedswitch-off:
ON/OFF key must be pressed for
approx. 4s to switch off the
display.
_F_AbS Access reset function: resetting to
reference value via key on
front of the display.
"oFF" Reset function off
"on" Reset function on
_F_rEL Accessincrementalmeasurement:
to switch from absolute dimension
andzero-settingtosubsequent
relativedimension
"oFF" Increm. meas. function off
"on" Increm. meas. function on
_F_rEF Access reference value: to enter /
changereferencevalue
"oFF" Referencevalue function off
"on" Referencevaluefunctionon
_F_oFF Access offset value: to enter /
change offset value
"oFF" Offset value function off
"on" Offset value function on
_SPEEd Toalterpowerconsumptionby
changingprocessor´sspeed.
"HI" Fullprocessorspeed
"Lo" Reducedprocessorspeedwithlow
powerconsumtion
_LAn_ Language:tochoosethelanguage
in which the menu points are to be
displayed
"d" German
"E" English
8. Input mode
Resetfunctionviakeyboard
• Presskey tosetthedisplaytothereference
value.
Precondition: Parameter 'Reset enable'
(_F_AbS) in programming mode must be pro-
grammed to "on", but unit must not be left in
programming mode (see chapter 6 'To leave
programmingmode').
Incrementalmeasurement
Pressthetwoarrowkeys + simultaneously
to activate incremental measurement function.
• The display is zeroed.
• The Display shows the blinking .
• Leaveincrementalmeasurementfunctionby
another simultaneous press of the two arrow
keys + . The absolute measuring value is
displayedagain.
• Whileintheincrementalmeasurementmode-
thedisplaycanalso be settozerobypres-sing
key . This does not change the absolute
measurementinthebackground.
Precondition:Menupoint'Incrementalmeasu-
rementenable'(_F_rEL)inprogrammingmode
mustbeprogrammed to "on", but unitmustnot
beleftinprogrammingmode(seechapter6‚'To
leaveprogrammingmode').
Referenceand/oroffsetvaluemodification
Press the two keys +simultaneously to
enteranewreference value.
Press the two keys +simultaneously to
enter a new offset value.