SiKom GSM Alarm Controller II Bedienungsanleitung

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 1 -
GSM Alarm Controller II
Instructions
-Remote control of heat
Possible to control up to 3 different outputs
-Alarm
GSM Alarm Controller II contains 4 inputs, and can send SMS
messages to 4 different numbers when an alarm situation
occurs
-Temperature
Temperature measurements between -29ºC and +49ºC.
Sends a SMS message when limits are reached.
Can control 1 output based on temperature
-Based on control by the GSM network
Any SIM card can be used
-Can be controlled by any phone with # and * keys.
-Choose your own personal code
-Status messages
SMS messages with complete status of the inputs, outputs,
power and temperature.

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 2 -
Table of contents
Page
1 Installation
1.1 Preparation of SIM card 3
1.2 Mounting SIM card 3
1.3 Power up 4
1.4 Signal strength 4
1.5 Local control 4
2 Remote control and user functions
2.1 Information about GSM remote control 4
2.2 How to remote control by phone 5
3 User menu
3.1 Main menu 6
3.2 Graphical overview 7
3.3 Activate multi SMS transmission 8
3.4 Switch control 8
3.5 Programming access code 8
3.6 Programming SMS numbers 9
3.7 Temperature control 10
3.8 Alarm functions 11
3.9 Status messages 12
3.10 Temperature surveillance 13
3.11 Limits for temperature surveillance 13
3.12 Other messages 14
4 Needs and useful information
4.1 GSM coverage 15
4.2 Control of heat 15
4.3 DTMF 15
4.4 Battery and power loss 15
4.5 Smoke detectors 16
4.6 Technical information 16

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 3 -
1 Installation
The following must be done with GSM Alarm Controller
II before use:
1.1 Preparation of SIM-card:
GSM Alarm Controller II needs a SIM-card to work. A SIM-card
is included from Sikom, but not activated. To activate this,
the information on the included form must be completed and
returned to Sikom. Fax nr. 74085970. Other SIM-cards from
different GSM-providers can be used. GSM Alarm Controller II
needs a SIM card with the PIN-code deactivated. This can be
done with an ordinary GSM-Phone. Put the SIM-card in a
regular phone, and follow the phones manual to deactivate the
PIN-code. (This is not necessary for the SIM-card provided by
Sikom)
1.2: Mounting SIM-card:
Be sure the GSM Alarm Controller II is turned off. (Should
always be turned off when something is done with the SIM-
card).
Remove the front cover on GSM Alarm Controller II as shown on
figure 1. Install the SIM-card as shown. The golden contact
points faced down.

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 4 -
If something is wrong with the SIM card or insertion of this,
the yellow LED will start flashing 3 times. Check the
deactivation of the PIN code of your SIM card and the lock of
the SIM card container, and try again.
1.3 Starting up
When all the connections are made, and SIM card inserted, the
GSM Alarm Controller II can be turned on. GSM Alarm
Controller II will use about 1 minute for self test and
registration on the GSM network.
1.4 Signal strength
The light on the keyboard will show the signal strength on
the GSM network.
Press * (star) on keyboard.
The light will blink in 3 ways:
1. Blinks green
Good signal.
2. blinks Red/green equally
Not so good signal. (-93->dB)
3. Blinks Red
Bad or no signal. (-103-> dB)
If point 2 or 3 occurs, the antenna should be moved for
better coverage.
1.5
Local control/front panel
All the outputs can be locally controlled by the switches on
top of the GSM Alarm Controller II. Push and keep the button
depressed for some seconds until the light changes. The
output is turned on when the light is green.
The alarm can be locally turned on and off by pressing your
code on the keyboard.
When the alarm is activated, you have about 10 seconds to
enter your code on the keyboard before the alarm responds.
2 Remote control and user functions
2.1 Information about GSM remote control
The GSM Alarm Controller II can be controlled by any phone
which contains the hash and star keys. The control is done by
the phones DTMF tones. These are the tones you can hear when
you press any button on the phone during a call. On some
phones, these tones need to be activated. Check your phone
manual.

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 5 -
When you call the GSM Alarm Controller II, you will get 4
tones:
1 Answer tone - Contains two Ok-tones
2 Approved - Contains 1 single tone
3 OK tone - Contains a low high double tone
4 Error tone - Contains three short beeps
If there's more than 30 seconds between each key press, the
GSM Alarm Controller will automatically hang up.
The GSM Alarm Controller II is protected by a personal code.
This code must always be entered at first when calling the
unit. If the wrong code is entered, the GSM Alarm Controller
II will hang up. To change this code, see point 3.5.
The factory code is 1234.
When you have dialled the GSM Alarm Controller and logged in
with the correct personal code, the main menu is always
active. If you press #the GSM Alarm Controller will
automatically hang on when this menu is active.
In the submenus, #has the following meaning:
# will take you back from a submenu to the main menu if you
accidentally press a wrong button. Then you can give another
command from the main menu. After 30 seconds of inactivity,
the GSM Alarm Controller automatically hangs up.
1 means ON and 0 means OFF.
Hyphen (””) covering the number in the menus means the number
should be pressed on your phones keypad.
2.2 How to remote control by phone
1. Dial GSM Alarm Controller. Wait for answer!
2. Press personal code. Wait for acknowledgement!
3. You are now in the main menu, and can choose between menus
1-9.

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 6 -
3 User menu
When the number to the GSM Alarm Controller II is dialed and
the personal code entered, the unit can be controlled by the
main menu and the sub menus as explained.
3.1 Main menu
Main menu:
-Menu 1: Multi sending SMS
-Menu 2: Output control
-Menu 3: Change personal code
-Menu 4: Programming SMS numbers
-Menu 5: Temperature control
-Menu 6: Alarm
-Menu 7: Status message
-Menu 8: Temperature surveillance
-Menu 9: Limits for temperature surveillance
Each of these main menus has sub menus as shown on the
pictures later. Several commands can be executed during the
same call. The GSM Alarm Controller II will automatically
return to the main menu after execution of a command.
In the explanation to the menus, the numbers which are to be
pressed on your phone encapsulated in hyphen like this ”2”.
The navigation through the menus is done the following way:
Chose the menu to enter. Choose sub menu, and then function.
Example: Turn on output 2; press ”2” then ”2” followed by ”1”
Shown graphically in the figure.

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 7 -
3.2 Graphical overview
This figure
shows the menu
structure of
the GSM Alarm
Controller II.
The boxes to
the right shows
the menus in
the main menu.
The center
contains the
sub menu, and
the left boxes
shows your
choices.

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 8 -
3.3 Menu 1 Activate multi SMS transmission
GSM Alarm Controller II can send alarm messages to 4
different numbers/receivers. Also called multi sending. These
4 numbers are stored in different positions by menu 4. To
activate the different numbers, menu 1 must be used. The
status messages are only sent to number 1. Number 1 can not
be deactivated.
-Press ”1”
-Press the position number of the SMS number you want to
activate/deactivate. ”2”, ”3” or ”4”
-”1” to activate, ”0” to deactivate
You are now returning to the main menu.
Example: ”131” activate position number 3, ”130”
deactivate.
3.4 Menu 2 Output control
The relays can be controlled manually on the top-card of the
GSM Alarm Controller II, or by phone as explained below.
1. Press “2” (after calling GSM Alarm Controller and logging
on) You are now in submenu 2, relay-control.
2. Press relay number - followed by “1” for ON or “0” for OFF
Command: Function: Command: Function:
“11” turn relay 1 on “10” turn relay 1 off
“21” turn relay 2 on “20” turn relay 2 off
“31” turn relay 3 on “30” turn relay 3 off
You will now get the OK tone which indicates function
executed.
To turn on/off more relays, you can now go back into menu 2,
and use another combination of the above commands.
3.5 Menu 3 Change personal code
Change the personal code by calling the GSM Alarm Controller
II. It is the same code which activates or deactivates the
alarm functions.
1. Press “3” .
2. Press new (self chosen) access code (4 digits)
3. Wait for approved
4. Press new access code once more (4 digits)
5. Wait for OK tone
You are now in the main menu!

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 9 -
Reset the personal code:
GSM Alarm Controller is delivered with code 1234.
If you wish to reset back to this code, do the
following:
Reset of the personal code can only be done as shown.
3.6 Menu 4 Programming SMS numbers
In order for the GSM Alarm Controller to send a SMS message,
the number to the recipient must be programmed.
4 different numbers can be programmed.
The status message can only be sent to number 1.
Remember to activate multi sending by using menu 1 if
desired.
-Press ”4”.
-Press the position of the number, ”1”,”2”,”3” or ”4”.
-Press the wanted phone/fax number
-End with star ”*”, wait for OK-tone.
You are now in the main menu!
If more numbers are to be stored, repeat the above
procedure.
Example: Store number on position 3: ”4 3 92239906 *”
You can verify the numbers entered by requesting status
message number 3.
(”7 - 3”). The numbers entered will be listed here.
If the GSM Alarm Controller II should send messages to a
phone/fax abroad, you need to press star “*” followed by
country code and phone number. The star will represent the
+ sign. (Example: Sweden: “4 3 *4692151515*”)
Hold button 3 on the GSM
Alarm Controller II
Press and release Reset
Keep holding button 3
for at least 5 seconds.
If the reset is
successful, 3 blinks
will be shown in the
reset indicator.

Sikom GACII v1.1 El-nummer: 64 309 33
www.sikom.no - 10 -
3.7 Menu 5 Temperature control
When temperature control is activated, relay/output 3 will
turn itself on when the temperature reaches 4 degrees and
below. It will turn itself of when the temperature reaches 6
and above. This will ensure constant temperature between
about 4 and 6 degrees Celsius given output 3 controls a heat
element which is capable of heating the entire room.
If you turn on output 3 by using menu 2, it will override the
temperature control.
-Press ”5”.
-Press ”1” for ON or ”0” for OFF, wait for OK tone.
You are now in the main menu!
Example: ”51” Turn ON, ”50” Turn off.
If a higher temperature than 4-6 degrees is wanted, the relay
can be turned on by using menu 2. The temperature control is
still active, and will resume operation when relay 3 is
turned off by menu 2 or local, until it is turned off by “50”
Inhaltsverzeichnis
Andere SiKom Sicherheitssystem Handbücher
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung