4 Programming
NOTE
Freely rotating active/hybrid Digital Cylinder AX only with shortened
range
With freely rotating cylinders, the reader knobs may not have sufficient
clearance at low cylinder lengths. Due to the range of the active techno-
logy, the radio signal can also be unintentionally received by the second
reader knob.
1. Program freely rotating cylinders with the SmartStick AX or the
SmartCD.MP.
2. Ensure that the short range is selected during programming (standard
setting for cylinders factory- supplied as freely rotating).
First transponder activation rejected after initial programming of AX products
If a transponder is the first identification medium to be activated after initial programming, the
transponder is rejected once and synchronised with the locking device in the background.
Transponders will then function as normal.
üLSM software version 3.5 or higher installed.
üLSM open.
üSmartStick AX, SmartCD.MP or SmartCD.G2 connected
(recommended: SmartStick AX).
1. Select the locking system that you require. Use the ... button to open
the locking system properties and use the and buttons to select
the required lock system.
2. Click on the button to add a new locking device.
9The "New lock" window will open.
3. Open the ▼ Area drop-down menu.
4. Select the area.
5. Open the ▼ Lock type drop-down menu .
6. Select the entry "AX cylinder".
7. Complete the rest of the form.
8. Click on the Save & next button.
9Locking device has been added.
9. Click on the Exit button.
9Window closes.
10. Select the entry for the AX locking cylinder in the matrix.
11. Position your programming device.
Padlock AX (Manual) 4. Programming
8 / 26