Chapter 2 Skybox Appliance specifications
Skybox version 11.6.100 8
PROPERTY LIMITS
Acoustic noise Sound pressure: 55 dBA (rack mount) in an idle state at typical office ambient
temperature. (23 +/- 2 degrees C)
Sound power: 7.0 dBA in operating conditions at typical office ambient
temperature. (23 +/- 2 degrees C)
Shock lOperating: Half sine, 2 g peak, 11 msec
lUnpackaged: Trapezoidal, 25 g, velocity change 136 inches/second (≧40
lb to <80 lb)
lNon-palletized free fall height: 24 inches (≧40 lb to <80 lb)
Vibration,
unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
ESD +/-12 KV except I/O port +/- 8 KV per Intel®Environmental test specification
System cooling
requirement
2027.7 BTU/hour
EMI operating Required to meet EMI emission requirements, tested as part of system
MTBF estimates for Skybox Appliance
The estimated mean time between failures (MTBF) and Failures in Time (FIT) for Skybox
Appliance 6000 are listed in the following table.
COMPONENT MTBF (HOURS) ESTIMATED FIT
Backplane board 935189 1069
PCI Riser Card 7303481 137
Front Panel board 8272282 121
Intel®Server Board S2600GZ 196253 5095
750W redundant power supplies (1+1) 806081 1241
Dedicated NIC module 2869529 348
Cooling fans 83131 12029
Total FIT rate 20178
System MTBF hrs @ 40°C 49560
System MTBF hrs @ 35°C 63214
System MTBF hrs @ 25°C 82325
Note: The estimates listed here are for Appliance in 35°C ambient air with a rise of up to 10°C
at the Server Board.
Front panel
Skybox Appliance 6000 front panel includes 2 USB connectors, a power button, and LEDs.