Smartswitch FR-4000 Bedienungsanleitung

SMARTSWITCH
FR-4000
Fire Alarm Monitor
Installation Manual

Introduction 1
System Components 2
Wiring Block Diagram 3
Connection Diagram for One Sensor 4
Connection Diagram for Multiple Sensors 5
Wiring Block Diagram –Single Engine Room Layout 6
Wiring Block Diagram –Twin Engine Room Layout 7
Wiring Diagram for FR-100 9
Connection Diagram for FEC-6 & FEC-1 10
Installation & Electrical Specifications 11
Mounting Instructions 12
System Overview 13
Relay Operations 14
Programming Instructions 15
Programming Instructions Cont. 16
Programming Instructions Cont. 17
Programming Instructions Cont. 18
Operating Instructions 19
Installation Instructions 20
Table of Contents

1
Introduction
Thank you for purchasing the FR-4000 Fire Alarm Monitor. Smartswitch is very proud to be able
to provide this product to you. You have selected a capable system designed to provide years of
reliable service under the most demanding conditions.
Smartswitch is a pioneer in the design and development of distributable intelligence controller
systems for the marine industry. The FR-4000 Fire Alarm Monitor is a versatile, compact,
modern, stylish, user-friendly intelligent network system. Our Research and Development Team
have developed this system specifically for the marine environment using proven techniques
and materials, which will ensure a long life at sea.
The FR-4000 provides features found only in expensive computer-based systems on mega-
yachts, but does so for a fraction of the cost. It is an economical and capable alternative to
simplistic monitoring systems. The FR-4000 allows builders and retrofitters to offer a system
with maximum functionality thereby providing boat owners with excellent visibility into any alarm
condition.
The main features are:
•12/24 volt auto detect
•Early detection and warning of engine room fire
•Full machinery shutdown management for up to six devices
•Fire detection throughout vessel
•Full monitoring of extinguisher trigger cupboard door
•Comprehensive fault monitoring
•Cylinder pressure monitoring
•Up to 4 zones

2
System Components
FR-4000 Master Display Unit (MDU)
Provides the following functions:
•12/24 volt
•Early detection and warning of engine room fire
•Full machinery shutdown management for up to six devices (see FEC-6)
•Comprehensive fault monitoring
•Cylinder pressure monitoring (see FEC-6)
•Latched display for up to 4 Alarms
oAll names are user programmable
oNetwork communication fault
oVisual alarm with tone
FR-100 Input / Output Unit (IOU)
The FR-100 is a controller, which provides 4 Zone Inputs for Smoke Sensors and 1
Output Relay.
•Each Input requires 4K7 end of line resistor for supervised line
•Minimum fault sense current = 8mA
•Output Relay’s
o10 A resistive @ 24VDC
oRelay 1 & Relay 2 close on Fire detection
oRelay 1 opens when alarm is muted
oRelay 2 opens when all zones are OK
FEC-1 Engine Relay Controller
The FEC-1 has one relay.
oOutput Relay 1 = 3 amp inductive
FEC-6 Engine Relay Controller
The FEC-6 has six relays.
oOutput Relay 1 to 4 = 10 A resistive @ 24VDC
oOutput Relay 5 & 6 = 1 A resistive @ 30VDC
Pyro-5 Pyrogen interface module
Monitor and release up to 5 Pyrogen extinguisher bottles.

3
Optional FEC - 6
Engine Room Controller
Engine shut down
Fan shut down
Evacuate light
Relays
Relays
4 core cable e.g. cat 5 (max length = 1000m)
Wiring Block Diagram
FR-4000
Master Display Unit (MDU)
Optional Sensors
Sensor
NOTE:
Sensors must have
4K7 ohm end of line
resistor fitted.
Battery negative
Battery positive
Relay 1
FR-100
(IOU)
Aux battery negative
Aux battery positive
Total Zone
Inputs = 4
Sensor Input Unit
Relay
Single Relay
Unit
Optional FEC - 1
Relay 2
Inputs
+Vdc
GND
Coms +
Coms -

4
Connecting One Sensor Per Zone
R
4K7
4K7 ohm end of line
resistor (EOL).
FR-100
(IOU)
Zone +
Zone -
Wiring for the extinguisher trigger
cupboard door
1k ohm
4K7 ohm
Normally open switch.
Switch closes when door
is opened.
FR-100
(IOU)
End of line resistor
Note: Detector manufactures use different terminal designators,
E.g. L1, L2 , L3 OR Com –, In + , Out +
Note: For HOCHIKI brand us terminals 1, 2, & 6
L1 or In + or 1
L or Com –or 6
L2 or Out+ or 2

5
R
R
R
FR-100
(IOU)
Connecting Multiple Sensors Per Zone
Note: Detector manufactures use different terminal designators,
E.g. L1, L2 , L3 OR Com –, In + , Out +
4K7 Ohm end of line
resistor (EOL).
Note: For HOCHIKI brand us terminals 1, 2, & 6
L1 or In + or 1
L1 or In + or 1
L1 or In + or 1
L or Com –or 6
L or Com –or 6
L or Com –or 6
L2 or Out+ or 2
L2 or Out+ or 2
L2 or Out+ or 2

6
Single Engine Room Layout
FR-4000
Master Display Unit (MDC)
FR-100
Zone
Sensor
Input Unit
Relay 1
Relay 2
Sensor
Gas cylinder
release door
switch
FEC-6
Engine
Relay Unit
Relay 1
Relay 2
Relay 3
Relay 4
Relay 5
Relay 6
Gas cylinder
pressure switch
Optional FEC-6 or FEC-1
FEC-1
Relay 1
4 Core Cable
Battery + & Battery -
Coms + & Coms -
Optional: Pyro-5
Pyrogen interface
module

7
Optional FEC-6 or FEC-1
Twin Engine Room Layout
FR-4000
Master Display Unit (MDC)
FR-100
Zone
Sensor
Input Unit
Relay 1
Relay 2
Sensor
Gas cylinder
release door
switch
FEC-6
Engine
Relay Unit
Relay 1
Relay 2
Relay 3
Relay 4
Relay 5
Relay 6
Gas cylinder
pressure switch
FEC-6
Engine
Relay Unit
Relay 1
Relay 2
Relay 3
Relay 4
Relay 5
Relay 6
Gas cylinder
pressure switch
FEC-1
Relay 1
FEC-1
Relay 1
4 Core Cable
Battery + & Battery -
Coms + & Coms -
Optional: Pyro-5
Pyrogen interface
module
Use FEC-1 or FEC-6 optional
Use FEC-1 or FEC-6 optional

8
FR-4000 Display Wiring Connections:
Connections
Red = +Vdc
Black = GND
Blue = Coms +
White = Coms -
Back View
White
Blue
Black
Red
Power and Comms Wiring Connections:
FR-4000
FEC-6
(Optional)
FEC-6
(Optional)
4 Core Cable Supplying
+ Vdc
GND
Coms +
Coms -
+ -
+ -
Aux Battery
Main Battery
FR-100
GND
Com +
Com –
+ Vdc
Out
Aux In
In