SOLIDSVAC SV200-SPDK-CF Bedienungsanleitung

SV200-SPDK-CF Operations Manual
201 First Avenue - Bribie Island - QLD 4507 - Australia
ISSUED DATE - 140421 LAST REVISED - 140421
SOLIDS PUMPING SYSTEMS
V 1.2

CONTENTS
Description
Safety First
1. Operation Overview
2. Design Registration
3. Technical Data
4. Accessories
5. Pump Set-Up
6. Operation
7. Maintenance
8. Adjusting the LOAD and DISCHARGE cycles
9. SV200-SPDK-CF Schematic
10. Main Components
11. Notes
Page
3
3
3
4
4
5
5
6
7
8
8
9
Scan this QR Code for an electronic version of this Operations Manual

www.solidsvac.com
page 3
SAFETY FIRST
CAUTION & GENERAL SAFETY
This manual contains important information concerning the installation, operation and maintenance of the Solidsvac Pump, Model
SV200-SPDK-CF. To prevent injury to personnel or equipment damage, this manual should be read and understood by those
responsible for the installation, operation and maintenance of the equipment.
- Isolate, tag out and disconnect the air supply to the unit prior to working on any part of the system
- Lift the equipment only at the lifting points provided
- The pump should be installed in a safe level area, which provides adequate access for operating the equipment
- Ensureallhosesareingoodcondition,correctlyratedandcertiedfortheserviceinwhichtheyaretobeused
- Inspect the unit regularly for damaged or worn components
- AllcoversMUSTbettedpriortooperation
- Air pressure should NEVER exceed the rated pressure
- Tiedownpoints(iftted)MUSTNOTbeusedasliftingpoints
CAUTION: BE AWARE OF RETAINED MATERIAL IN THE TANK INCREASING WEIGHT
CAUTION: SOLIDSVAC RECOMMENDS THE FITMENT OF 3-WAY T & MANUALLY OPERATED KNIFE GATE VALVE
TO REDUCE PRESSURE IN THE EVENT OF A DISCHARGE LINE BLOCKAGE
Prior to operating the Solidsvac Pump:
- Ensureoptimumairsupplyis380cfm@690kPa(100psi)
- Itisrecommendedthata50mm(2”)i.d.airhoseisusedforcompressedairsupplytothepump
- Thepump-outdischargelineshouldbeaminimumof100mm(4”)diameter
WARNING: THE PUMP-OUT LINE MUST BE SECURED AT THE EXIT POINT
1. OPERATIONAL OVERVIEW
The Solidsvac SV200-SPDK-CF operates as a shuttle system
alternatelydischarging,thenloadingawiderangeofowable
materials.
Operation is both manual and fully automatic and the
Solidsvac SV200-SPDK-CF features no internal workings, high
vacuum and pressure discharge where suction of up to 50
metres and discharges of up to 500 metres are achievable.
2. DESIGN REGISTRATION
TheSolidsvacSV200-SPDK-CFhasaCerticateofPlantDesign
Registration from Workcover NSW, Australia. A copy of which
may be obtained by contacting Solidsvac Pumps.
DESIGN REGISTRATION # PV-6-204612/16
Technical Standards
- AS2971-2007 Serially Produced Pressure Vessels
- AS4343-2005 Pressure Equipment – Hazard Levels
- AS1210-1210 Pressure Vessels

telephone +61 456 000 665
email [email protected]
page 4
3. TECHNICAL DATA
Note: All performance statistics listed were measured on water and will require 7 bar (100 psi) operating pressure.
4. ACCESSORIES
Suction Wand - Attaches to the suction hose allowing the operator to
stand upright.
Large Capacity Strainer - Attaches to the suction hose to prevent
blockages.
Delivery Carousel - Discharge to multiple skips.
Hoses - A complete range of high quality suction and discharge hoses.
Duck Bill Vacuum Head - Helps focus the vacuum and is ideal for
recoveringspilledoil,drillmudorsimilarfromtherigoorortankbottoms.
Dropbox - Delivery to skip or conveyor.
Tool Kit - Contains all you need for basic maintenance on your pump.
Service Kit - Contains all you need for basic maintenance on your pump.
Height 1400 mm 55”
Width 1150 mm 45”
Length 1650 mm 65”
Weight 800 kg 1212 lb
Air inlet 51 mm 2” BSP
Suction Lift 100 mm 4”
Discharge outlet 1000 mm 4”
Delivery 500+ m 1640+ ft
Suction lift 15m+ @ 380 cfm
Up to 25m @ 600 cfm 49' ft+ @ 380 cfm
Up to 82' ft @ 600 cfm
Air consumption 10.7 m3/Min Jetpack
16.9 m3/Min Jetpack 380 cfm Jetpack
600 cfm Jetpack
Displacement cycle 190 ltr 50 gal
Operating pressure 7Bar(Required)@690kPa 100psi(Required)
Measured Water Throughput 665lpm(380cfm)
900lpm(600cfm) 175gpm(380cfm)
237lpm(600cfm)
Maximum solids 65 mm 2-1/2”
Air Consumption Options 76 to 88 kPa 22.5" to 26" Hg
TECHNICAL DATA METRIC US IMPERIAL

www.solidsvac.com
page 5
5. PUMP SET-UP
Beforecommencingoperation,SolidsvacPumpsrecommendsthatasitebasedRiskAssessment(RA)ofthepumpingoperationis
undertaken. Any recommendations arising from the Risk Assessment would be additional to the following.
Before operating the Solidsvac SV200-SPDK-CF check:
A) Theunitandallhosesandttingsareundamagedandingoodworkingorder.
B) Allcoversarettedandclosed.
C)Cleancompressedairataminimumworkingpressureof690kPa(100psi)at380cfm(or600cfm)isavailable.
D)A51mm(2”)airhoseisavailable.
E) Thedischargeareahassuitablewarningstoprotectpersonnelareinplace.
F) ThecorrectPPEisavailableandwornforoperatingcompressedairequipment.
Note: The Solidsvac Pump requires NO lubrication.
1) SettheSolidsvacPumpupinasafe,levellocationnearthematerialtobepumped.
2) Attachbothsuctionanddischargehosesalongwithanyaccessories(SuctionWand,DropBox,DeliveryCarousel)asrequired
and ensure safety clips are in place.
*Always position hoses out of walkways where possible.
3) Ensurethemainairvalveisintheoffpositionandattachthe51mm(2”)airhosetotheSolidsvacPumpandtappropriate
safety clips.
4) Thepumpisnowreadyforuse.
CAUTION: Solidsvac recommends that the SV200-SPDK-CF unit, should be operated rstly in the Manual setting. Manual operation
will ensure safe & correct timing cycles are achieved.
6. OPERATION
Turn the air supply valve on at the source followed by the valve on the pump.
Turnthesecondarylevertomanualandtherstlevertosuction.Thepump
will now commence operation.
Once a desirable operation is achieved, the automatic setting can be
selectedandthepumpcanbeleftrunningunattendedindenitely.
- Solidsvac Pumps recommend checking the pump out-line to ensure it
remains correctly anchored at the exit.
NOTE: Dry operation will not damage the pump.
- When pumping is complete, isolate the air at the pump and then the source.
- To release pressure from the air supply line turn on the pump air valve.
(Thepumpwillcycleuntilthereisinsufcientairtooperate.)
- Select pump air valve to off.
SAFETY FIRST
ISOLATE AIR SUPPLY
VALVE AND HAVE AIR
SUPPLY VALVE OFF
BEFORE COMMENCING
ANY WORK ON THE UNIT
REPORT ANY DEFECTS
IMMEDIATELY

telephone +61 456 000 665
email [email protected]
page 6
Remove exhaust box
lid for cleaning
7. MAINTENANCE
In use, the Solidsvac SV200-SPDK-CF requires no maintenance. However the following procedures are recommended in the event of
anylossofvacuumwhenoperatingineitherin-lineorETA(ExhausttoAtmosphere)mode.
Prior to commencing each pumping operation:
- Checkthatallttingsandconnectionsareserviceable.
- Inspect exhaust box to ensure it is free from any carry-over material.
NOTE: Regular visual inspection of the knife gate seals are also recommended.

www.solidsvac.com
page 7
8. ADJUSTING THE LOAD AND DISCHARGE CYCLES
Adjusting the Load and Discharge cycles may be required depending on material being transferred and the distances
involvedetc.Turningtheupperowrestrictortonegativewilldecreasetheloadingtime,similarlyrotatingittopositivewillincrease
the load time.
The Pressure Relief Valve can be manually operated via the lever as indicated below.
Caution: It is recommended that only a quarter turn adjustment is made at a time.
Note: Numbers found on cycle timers are a guide only.
Pressure Relief Valve Cycle Control Timers
SAFETY FIRST
PRIOR TO COMMENCING ANY WORK ON THE UNIT, THE AIR SUPPLY VALVE MUST BE
ISOLATED AND THE CONTROL SYSTEM TESTED DEAD

telephone +61 456 000 665
email [email protected]
page 8
10. MAIN COMPONENTS
Exhaust Box
Discharge
Suction
Control Box
Air Supply
Fork Skids

www.solidsvac.com
page 9
10. NOTES

201 First Avenue - Bribie Island - QLD 4507 - Australia
www.solidsvac.com
Model Number
Serial Number
Date of Manufacture
Inspected by
Inhaltsverzeichnis
Andere SOLIDSVAC Wasserpumpe Handbücher
Beliebte Wasserpumpe Handbücher anderer Marken

Sykes AmeriPumps
Sykes AmeriPumps GP100M Fehlerbehebungshandbuch

DUROMAX
DUROMAX XP WX Series Bedienungsanleitung

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Bedienungsanleitung

Franklin Electric
Franklin Electric IPS Bedienungsanleitung

Xylem
Xylem e-1532 Series Bedienungsanleitung

Milton Roy
Milton Roy PRIMEROYAL Bedienungsanleitung