SORG Boogie Fix & Boogie Swing Series Service-Handbuch

1 of 28
2019-08-12 Service Record Boogie Fix and Swing Unique people, unique solutions.
Service Record Boogie Fix and Swing
ENG
Boogie
Fix & Swing
Service Record
In the following all individual adjustments of the standing aid are
described. These adjustments require tools and specialised
knowledge. Please leave the adjustments to a qualied rehab
consultant.

2 of 28 Service Record Boogie Fix and Swing 2019-08-12
Imprint
SORG Rollstuhltechnik GmbH+Co.KG
Benzstraße 3-5
68794 Oberhausen-Rheinhausen / Germany
Tel. +49 7254-9279-0
Fax +49 7254-9279-10
E-Mail [email protected]
Web www.sorgrollstuhltechnik.de
Revision status
2019-08-12
Technical status
Technical changes and misprints reserved. The
pictures in this Instructions for use can dier
from the actual equipment components. How-
ever, a corresponding conduction is possible.
Copyright
All texts, pictures and graphics underlie co-
pyright protection. All rights, including co-
pying, publishing, editing and translating,
remain reserved. © by SORG Rollstuhltech-
nik GmbH+Co. KG Benzstraße 3-5, 68794
Oberhausen-Rheinhausen / Germany.
Our terms and conditions can be found
on our order forms and at www.sorgrollstuhl-
technik.de/impressum.

3 of 28
2019-08-12 Service Record Boogie Fix and Swing
Table of content
1 Standing aid overview 4
2 General information 5
2.1 General indications 5
2.2 Documentation indications 5
2.3 Required torques and tools 5
2.4 Explanation of symbols 6
2.5 General safety instructions 7
3 Assembly Groups 8
3.1 Assembly Group Centre column 8
3.1.1 Height adjustment 8
3.2 Assembly Group leg support 9
3.2.1 Height adjustment 9
3.2.2 Position the diveded foot plates 9
3.2.3 3D footplate with angle adjustment10
3.3 Assembly Group foot shells 11
3.3.1 Shift 11
3.3.2 Move 11
3.4 Assembly Group Knee truss pad 12
3.4.1 Standard knee truss pad 12
3.4.2
Knee truss pads with resting brackets
13
3.5 Assembly Group Posterior truss pad 15
3.5.1 Posterior truss pad pluggable 15
3.5.2 Posterior truss pad with swivel
bracket 16
3.6 Assembly Group Pelvis truss pad 17
3.7 Assembly Group Pelvis truss pad 18
3.7.1 Pelvis truss pad 18
3.7.2 Side pelvis truss pad 18
3.8 Assembly Group Belt 20
3.9 Assembly Group back truss pad 21
3.10 Assembly Group Theraphy table 22
4 Repairs and maintenance 23
4.1 Repairs 23
4.2 Spare parts 23
4.3 Maintenance 23
4.4 Disinfection 23
4.5 Storage 23
4.6 Reinstatement 24
4.7 Disposal 24
4.8 Maintenance/ Inspection 24
5 Technical specications 26
5.1 Data and measurements 26
5.2 Meaning of label 27
5.3 Declaration of conformity 27

4 of 28 Service Record Boogie Fix and Swing 2019-08-12
1 Standing aid overview
Overview Boogie Swing
Overview Boogie Fix
1
4
2
6
7
1chest truss pad
2arm pad
3therapy table
4centre column
5knee truss pad
6frame „Fix“
7casters
1chest truss pad
2back truss pad
3side chest truss pad
4spine truss pad
5side posterior truss pad
6posterior truss pad
7knee truss pad
8centre column
9frame „Swing“
10 leg support
11 standing feet
1
2
3
4
5
6
7
8
10
11
9
3
5

5 of 28
2019-08-12 Service Record Boogie Fix and Swing
2 General information
2.1 General indications
In the following all individual settings, adjustments and repairs as well as the yearly inspection
of the standing aid are described. These adjustments require tools and specialised knowledge.
Please leave the adjustments to a qualied rehab consultant.
Should questions or suggestions come up then please contact your medical supply store or our
team (+49 7254 9279-0).
2.2 Documentation indications
Please note:
• Information about before sale can be found in the instructions for use
• Infomation for the user can be found in the instructions for use
• For maintenance instructions see: Chapter 4 (Repair & Maintenance)
2.3 Required torques and tools
For the following screws needed torque:
• M5: 5 Nm;
• M6: 7 Nm;
• M6 (axle plate) 10 Nm
• M8: 20 Nm;
• M10 (nut): 25 Nm; (caster)
• quick release axle tting 40 Nm
Needed tools:
• torque wrench (5-50 Nm)
• open end wrench
• ex ratchet handle with socket wrench inserts
• hexagon screw driver
• Phillips screw driver
• at head screw driver
• plastic mallet
• side cutter
• threadlocker (uid)
• bicycle inner tube repair kit
• work bench/jaw vise with rubber pads

6 of 28 Service Record Boogie Fix and Swing 2019-08-12
2 General information
2.4 Explanation of symbols
ATTENTION! Warnings for perso-
nal Safety aspects that are of the
utmost importance.
CORRECT safety adjustment/ use
WRONG adjustment/ use
NOT ALLOWED
References to additional/conti-
nuing reading.
Setting or adjusting the angle
open/ close
Turn clockwise
Turn counter-clockwise
steps to be done at the same
time
steps to be done after each other
steps to be done on both sides
Use
(A); (B)
1. 1.
1. 2.
;
2x
push/ pull/ insert / move/
Push in specic direction
important detail
correct or proper use/setting
incorrect or improper use/setting
reference from text to detail
point of view
view from top
view from the side
view from the bottom
view from the front
view from the back
fasten parts
remove parts

7 of 28
2019-08-12 Service Record Boogie Fix and Swing
2 General information
2.5 General safety instructions
Check before every use:
• the rm seat of all pads,
• Frames, attachments and accessories for visible damage, bends, cracks or missing / loose
screws,
• Wheels / thru axles on rm seat,
• sucient tire pressure, tire tread,
• Functioning of the brakes,
• tight t of the locking mechanisms (tripod springs, thru axles, eccentric tensioners, etc.),
whether all previously dismantled parts are plugged in again and rmly locked.
There is a risk of injuries (such as bruising) to all rotating, rotating or folding parts, inclu-
ding adjustments, repairs and transport.
All standing aid parts are to be handled properly. Do not throw or drop removable parts!
Before starting the test, repair or adjustment work, clean / disinfect the standing aid and
secure it against tipping over and / or falling down.
Use only original spare parts.
Safety nuts may only be used once. Once loosened safety nuts must be replaced by new
ones.
Only the regular maintenance of all safety-related parts on the standing aid by a qualied
rehab workshop protects against damage and maintains our manufacturer's warranty.
When adjusting the angle of the central center column via telescope and clamping lever,
there must not be any users in the standing aid.
The standing aid may only be used indoors, on level (horizontal) and rm ground and
only by the patient for whom it has been adapted. Outdoor use is not permitted.
Structural changes must not be made without our express permission. They must be exe-
cuted and documented by us or by an authorized rehab technician.

8 of 28 Service Record Boogie Fix and Swing 2019-08-12
3.1 Assembly Group Centre column
3.1.1 Height adjustment
In the frame version "Fix" and in the frame
version swing size 1, the center column can be
adjusted in height. For taller people, use the
lower mounting holes, and for small people,
the upper mounting holes.
Should it become necessary to move the cen-
ter column:
• (1) Secure the standing aid against rol-
ling by operating the kick pedals on the
castors.
• Remove the screw(s) (A) and the
spacer(s) on the center column (B).
• Move the center column (B),
• replace the screw(s) (A) and the
spacer(s)
• and turn it tight.
(A)
(B)
(1)

9 of 28
2019-08-12 Service Record Boogie Fix and Swing
3.2 Assembly Group leg support
3.2.1 Height adjustment
For all adjustment work on the footplates, the user ist not allowed to stand in the standing
aid.
In the frame version "Swing" the footplate can
be adjusted in height:
(1) Position the footplate(s) for easier entry
and exit from the standing aid as close as pos-
sible to the oor.
(2) For smaller body sizes it may be necessary
to insert the footplate(s) higher in the center
column.
(3) To adjust the height of the footplate holder
(A):
• Loosen the grub screw (B)
• and remove the screw (C).
• Place the footplate holder (A) in the
center column (D) along the holes (E).
• Insert the screw (C) again and turn it
tight.
• Tighten the set screw (B) again.
(1) (2)
(3)
(B)
(A)
(C)
(D)
(E)
3.2.2 Position the diveded foot plates
(4) To adjust the position:
• Loosen the screws (A),
• move the foot plates (C) to the desired
position
• and tighten all screws (A) again.
(4) (A)
(A)
(A)
(C)
(C)

10 of 28 Service Record Boogie Fix and Swing 2019-08-12
3.2 Assembly Group leg support
3.2.3 3D footplate with angle adjustment
The 3D footplates can be separately adjusted,
tilted and rotated three-dimensionally.
(1) For 3D angle adjustment:
• Release the clamp lever (A) and move
the footplate to the desired inclination /
position / turn.
• Turn the clamping lever (A) very tight
again.
Then check the tightness of the footpla-
te if necessary tighten the clamping lever (A)
more tightly.
(1) For abduction:
• Loosen the setscrew (B) and move the
footplate along the support (C) to the
desired position.
• Tighten the set screw (B) again.
(2) For height adjustment:
• Loosen the setscrew (A) and
• move the respective footplate along the
support (B) to the desired position.
• Close the adjusting screw (A) again.
(2) For depth adjustment:
• Loosen the setscrew (B) and remove the
footplate holder (D) completely.
• Turn the bracket (D) 180 ° and
• Mount it back on the carrier (C).
• Tighten the set screw (B) again.
(2)
(B)
(A)
(1) (D)
(B)
(C)
(A)
Inhaltsverzeichnis
Andere SORG Mobilitätshilfe Handbücher
Beliebte Mobilitätshilfe Handbücher anderer Marken

Rhythm Healthcare
Rhythm Healthcare B3800F Bedienungsanleitung

AMF-BRUNS
AMF-BRUNS PROTEKTOR Bedienungsanleitung

Drive DeVilbiss Healthcare
Drive DeVilbiss Healthcare OTTER Bedienungsanleitung

Rhythm Healthcare
Rhythm Healthcare C500U Bedienungsanleitung

Lumex
Lumex RJ4200A Bedienungsanleitung

Rebotec
Rebotec Jumbo Bedienungsanleitung