STAUFF PT-RF Series Bedienungsanleitung

Manual
Pressure Transmitter and Reader
of the PT-RF Series

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 2 of 30
Contents
1Safety instructions.................................................................................................................................3
1.1 Intended use.........................................................................................................................................3
1.2 Specialist personnel..............................................................................................................................3
1.3 Accuracy of technical documentation....................................................................................................3
1.4 High-pressure applications....................................................................................................................4
1.5 Service/repairs......................................................................................................................................5
1.6 Information about disposal....................................................................................................................5
2Scope of Supply....................................................................................................................................7
3Reading device Reader-PT-RF .............................................................................................................8
4Pressure transmitter PT-RF...................................................................................................................9
4.1 Installing the pressure transmitters.............................................................................................9
5Carrying out a measurement...............................................................................................................10
5.1 Preparing a measurement........................................................................................................10
5.2 Individual measurement ...........................................................................................................12
5.3 Continuous measurement ........................................................................................................13
6Functions.............................................................................................................................................15
6.1 Storage battery.........................................................................................................................15
6.2 Energy saving function.............................................................................................................15
6.3 Status indicator (LED)..............................................................................................................16
6.4Measurement process..............................................................................................................17
7Software..............................................................................................................................................18
7.1 Installation................................................................................................................................18
7.2 The Interface............................................................................................................................19
7.3 Connecting a reader.................................................................................................................20
7.4 The measurement list...............................................................................................................20
7.5 Function-Buttons......................................................................................................................23
7.6 Set-Buttons ..............................................................................................................................26
7.7 Filter Options............................................................................................................................27
8Maintenance/cleaning/repairs..............................................................................................................28
8.1 Repairs and Service.................................................................................................................28
9Technical Data ....................................................................................................................................29
9.1 Pressure transmitter.................................................................................................................29
9.2 Reading device ........................................................................................................................30

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 3 of 30
1 Safety instructions
1.1 Intended use
This portable reading device is intended for measuring, storing and
monitoring measuring values, e.g. for service and maintenance work as well
as in the field of machine optimisation. The device is only intended for use
with a pressure transmitter and accessories from the STAUFF PT-RF
accessories range. Any other use is not permitted. This can lead to
accidents or destruction of the device and will result in immediate expiration
of any warranty and guarantee claims towards the manufacturer.
Warning
Using the selected product outside the specifications or disregarding the
operating and warning information can result in serious malfunctions that
may cause injuries and property damage.
The device must not be operated in explosive atmosphere!
1.2 Specialist personnel
These operating instructions are intended for trained specialist personnel
who are familiar with the current regulations and standards for the area of
application.
1.3 Accuracy of technical documentation
These operating instructions were created with the greatest care. We accept
no liability for accuracy and completeness of the data, images and drawings.
Subject to change.

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 4 of 30
1.4 High-pressure applications
The overload pressure should not be exceeded when selecting the pressure
transmitters. The pressure transmitter can be damaged if the overload
pressure is exceeded (depending on length/frequency and height of the
pressure spike).
In case of air inclusions, the “diesel effect” can create pressure spikes which
far exceed the overload pressure.
The nominal pressure of the pressure transmitter should therefore be greater
than the nominal pressure in the system to be measured.

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 5 of 30
1.5 Service/repairs
Please contact your sales office for repair of the reading devices.
1.6 Information about disposal
Recycling in line with WEEE
Buying our product means that you have the opportunity to return the device
to the sales office after the end of its life cycle.
The WEEE (EU Directive 2002/96/EC) governs the return and
recycling of old electrical appliances. In the B2B (business to
business) field, as of 13 August 2005 manufacturers of electrical
appliances are obliged to take back and recycle any electrical
appliances sold after this date free of charge. Electrical appliances
must therefore not be introduced into the “normal” waste streams. Electrical
appliances have to be recycled and disposed of separately. All appliances
which are affected by this guidelines are marked with this logo.
What can we do for you?
We therefore want to offer you a cost-neutral option for returning your old
appliance to us. We will then recycle and dispose of your appliance in line
with current legislation.
What do you need to do?
When your appliance has reached the end of its lifetime, simply send it to
your sales office using a courier service (in the box). We will then take on
any recycling and disposal measures. This means you have no costs and no
troubles.
Any questions?
Please contact the sales office if you have any further questions.

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 6 of 30
Information about battery disposal
In the EU, the disposal of batteries is subject to the Battery Directive
2006/66/EU, in Germany to the Battery Act (BattG) dated 25 June 2009 and
internationally to the respective national legislation.
Batteries must never be placed in household waste.

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 7 of 30
2 Scope of Supply
-reading device Reader-PT-RF
-power supply unit 230/110 V 1.2 A
-USB 2.0 cable
-software on CD
-Quick Guide

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 8 of 30
3 Reading device Reader-PT-RF
micro USB connection
measuring key/function key
on/off button
antenna
display
Status display (LED)

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 9 of 30
4 Pressure transmitter PT-RF
4.1 Installing the pressure transmitters
The pressure transmitter has a G1/4 or 1/4NPT process connection,
depending on the version.
The pressure transmitter has to be installed in line with these connections.
Connection using STAUFF Test SDA adaptors can be fitted for direct
connection with test couplings.
It should be ensured that there is sufficient space above the plastic cap to
allow reading out the values with the Reader-PT-RF reading device.
The ambient temperature must not exceed + 85 °C / + 185 °F.
Process connection G1/4 (B04)
Process connection 1/4NPT (N04)

Walter Stauffenberg
GmbH & Co. KG
Im Ehrenfeld 4 D-58791 Werdohl Phone +49 (0) 2392 916-0
Operating instructions PT-RF V1.3 page 10 of 30
5 Carrying out a measurement
5.1 Preparing a measurement
Start the reading device before carrying out a measurement.
To do this, press the key.
The reading device will start with the start screen which displays the
charging state and the available free memory.
Set time and date before using the reading device. This cannot be carried
out on the actual reading device but has to be done through a connection to
a PC. The PT-RF-SOFT software allows setting the time and deleting the
memory there.
It can also be set whether pressure values should be displayed in bar and °C
or in psi and °F.
charging status
charging state
memory used
date
time
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Beliebte Sender Handbücher anderer Marken

Dejero
Dejero EnGo 3x Bedienungsanleitung

Rosemount
Rosemount 4600 Bedienungsanleitung

Speaka Professional
Speaka Professional 2342740 Bedienungsanleitung

trubomat
trubomat GAB 1000 Bedienungsanleitung

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Bedienungsanleitung

Rondish
Rondish UT-11 Bedienungsanleitung











