Group Name Page
Instructions for Use..................................................................................... 6
Troubleshooting.......................................................................................... 7
RPX-65011................................................................................................. 8
RPS-65011............................................................................................... 10
RPB-65011............................................................................................... 12
RPB7-65011............................................................................................. 14
RPKS-65011* ........................................................................................... 16
RPXL-65011............................................................................................. 18
* Submersible Trash

4
Thank you for choosing a Subaru Submersible Pump.
This manual is prepared for your safety when operating the pump.
Please read carefully and comprehend fully before use.
(Wrong usage could cause injury or death.)
Please keep this manual handy for future reference.
PLEASE READ MANUAL BEFORE OPERATION.
“ACCEPTABLE FOR INDOOR OR OUTDOOR USE”
“SUBMERSIBLE PUMP”
CAUTION
Before use, please make sure to read the instruction manual.
Do not operate the pump out of water or insufficient water.
WARNING
Risk of electric shock. This pump is supplied with a grounding conductor and
grounding-type attachment plug. To reduce risk of electrical shock, connect only
to a properly grounded, grounding-type receptacle.
TO REDUCE THE RISK OF ELECTRIC SHOCK, INSTALL ONLY ONA CIRCUIT
PROTECTED BYA GROUND-FAULT CIRCUIT-INTERRUPTER (GFCI).
NOTE
This pump is not intended for use where water is occupied by people. This pump
is intended for use with water only.

5
CAUTION
Ground Fault Circuit Breaker
For home use, connect to a GFCI receptacle (if available) to ensure safety.
Connect the power source
This pump is to be connected to a 120 volt, 60 hertz power source.
Application
This pump is not intended for use in any oil, sea water, strong alkaline or strong acidic solution, or
any agricultural chemicals.
Do not run dry
To avoid damage to the pump, place the pump at the deepest position in the water. Running the
pump without water will result in damage to the seals.
Handling of the power cord
Never lift or move the pump by the power cord. Only lift by handle or rope tied to handle. Select
and use proper size extension cord.
Instructions for use
Check the nameplate for output and voltage required for the pump. Improper voltage may result
in damage to the pump.
Placement of pump
The pump can be used in most places. But avoid continuous short-water operation at a sandy
place, as it may accelerate wear of the pump. Install the pump at a position where water can
be collected the easiest. When the pump is installed on soft, muddy or sandy ground, place the
pump on a solid surface to prevent the pump from sinking in the mud. Strictly refrain from putting
into any pond, bath, or swimming pool which is occupied by people.
Hoses
When any hose is used for connection, keep the hose as straight as possible as excessively bent
hose reduces water quantity. Refrain from placing the discharge port under water as efficiency
may be reduced and damage may occur.
Power Cord Cable
To move or install the pump, hold the pump by the handle or a rope tied to the handle. Do not
use the power cord cable to pull the pump as damage to the internal wires may result. Use exten-
sion cords of the same or larger size as the pump. Do not put the power cord connection in the
water as electrical shock may occur.
Ground Wire
Be sure to connect the ground wire before connecting the power cord cable to the power source.
Thermal protector
The pump incorporates a thermal protector to protect the motor. If the motor is stopped auto-
matically at an over-load operation such as clogged intake or low or no water, turn off the power
source and inspect pump, prior to re-starting.

6
Storage
If the pump has been used for pumping water with a high sand content, continue running pump
with clean water to clean out any debris prior to storage.
After using the pump
In cold climates, do not allow water in the pump to freeze. Completely drain and dry the pump of
water prior to storage.
Maintenance and inspection
Periodically check the insulated condition with a megger tester (insulation resistance tester). The
acceptable resistance between the ground wire and the power cord should be 100Meg ohm or
higher.
The shaft of the water-tight pump is sealed with liquid paraffin. The quantity of liquid paraffin
should be checked periodically. Use 170cc of Crystol No. 70 by Exxon Mobil Corporation for the
sealing. The liquid paraffin can be checked easily by removing the hexagon socket head bolt at
the side of the pump body.
CAUTION
The pumps use a double mechanical seal. (See Figure)
Consult the following table for assembly.
Mechanical
Seal Motor Side
(Carbon) Pump Side
(Carborumdom)
Outside
Diameter 22.5mm 20.5mm
Internal
Diameter 18.5mm 15.0mm

7
PROBLEM POSSIBLE CAUSE SOLUTION
No start at all or stops
immediately after start
Not properly connected to
power circuit Correct connection
The GFCI, leakage circuit
breaker is actuated Check the power circuit
The impeller is caught by
foreign substance Repair the point of
leakage
Motor is burnt Repair or replace
Voltage drop Raise the voltage to the
rating
Failure during operation The thermal protection is
actuated
Remove foreign
substance if the impeller is
clogged
Lower the water temperature
if it is too high
No pumping or poor
performance
Voltage drop Raise the voltage to the
rating
High delivery head Lower the head
Discharge hose is clogged Unclog hose
Impeller wear Replacement
Clogging of foreign matter in
strainer pump Unclog hose
TROUBLESHOOTING

8
RPX-65011

9
RPX-65011
Ref # Part Number Description Qty
1 0438067 Motor Ay 1
2 0430399 Frame 1
3 0430267 Bracket 1
4 0430284 Head Gasket 1
6 0430308 Power Cord 1
7 0438066 Chain Ay 1
8 0390031 Cord Supporter 1
9 0260018 Cord Band 1
10 0430404 Handle 1
11 0430441 Adjusting Washer 2
12 0430280 Impeller 1
13 0430273 Back Liner 1
14 743605031 Hex Bolt 4
15 0430271 Front Cover 1
16 889955125 O ring 1
17 734505037 Hex Socket Bolt 3
18 0430243 Mechanical Seal 1
20 0390025 Adjusting Washer 2
21 0390037 Hex Socket Bolt 1
22 854255010 Seal Washer 2
23 0430274 Casing 1
24 0430269 Suction Flange 1
25 0430270 Strainer 1
26 0430306 Delivery Flange 1
Ref # Part Number Description Qty
27 0430383 Delivery Flange Gasket 1
28 0430290 Stud Bolt 2
29 846005008 Washer 5
30 835305008 Hex Cap Nut 3
31 0390101 Rope 1
32 735705162 Hex Bolt 3
33 0340142 Seal Ring 1
34 0340153 Screw 1
35 0340277 Thrust Washer 1
36 895154014 Oil Seal 1
37 Label 1
38 Caution Label 1
39 0430299 Thrust Gasket 1
40 707820074 Screw 1
41 703305100 Screw 2
42 827305005 Hex Nut 1
43 Label 1
44 703305102 Screw 2
45 845305008 Toothed Washer 1
46 846505008 Washer 1
47 940019060 Hose Band 1
48 0430392 Condenser 1
49 734605035 Hex Bolt 3

10
RPS-65011
Dieses Handbuch passt für folgende Modelle
5
Inhaltsverzeichnis
Andere Subaru Wasserpumpe Handbücher
Beliebte Wasserpumpe Handbücher anderer Marken

Fieldmann
Fieldmann FVC 5015 EK Bedienungsanleitung

Everbilt
Everbilt EFSUB5-122HD Bedienungsanleitung

Graco
Graco Husky 3300e Bedienungsanleitung

esotec
esotec 101018 Bedienungsanleitung

Becker
Becker BASIC VASF 2.80/1-0.AC230 Bedienungsanleitung

Sykes AmeriPumps
Sykes AmeriPumps GP100M Fehlerbehebungshandbuch

DUROMAX
DUROMAX XP WX Series Bedienungsanleitung

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Bedienungsanleitung

Franklin Electric
Franklin Electric IPS Bedienungsanleitung

Xylem
Xylem e-1532 Series Bedienungsanleitung

Milton Roy
Milton Roy PRIMEROYAL Bedienungsanleitung

STA-RITE
STA-RITE ST33APP Bedienungsanleitung