7
ENGLISH•User's Manual
TECHNICAL DATA
OPERATION INSTRUCTIONS
1. Adjust the
headgear dia-
meter with the
twist knob on
the back. The
knob is locked
until pushed in.
Once unlocked,
twist clockwise
to tighten and
counterclockwi-
se to loosen.
2. Adjust the
height by snap-
ping the pin into
the hole to lock securely in place.
3. To adjust the viewing angle, loosen the knob
on both sides of the helmet and change angle
locker to the desired tilt position (5 selection
and positioned in the middle by default). Once
achieving the desire angle, tighten the knobs
until snug. The helmet should still swing up, but
it should not drift downward when in place for
welding.
4. To adjust the distance between the user’s face
and ADF, loosen the knobs on both sides of the
helmet until the headband can move back and
forth freely, reposition the headband at one of
the 3 slots as desired (The headband is positio-
ned in the middle by default). This should be
done one side at a time and both sides should
be located at the same position for proper auto-
darkening filter operation.
SELF-CHECK
Press the TEST Button anywhere to see if it au-
tomatically switches to dark state and release it
to check that the filter returns to the light state.
SHADE CONTROL
Select the shade 9 to 13 based upon the welding
process you will use by consulting the “Shade
Guide Table”. The welding helmet can also be
used to protect the face when grinding. Grind
mode prevents filter lens from auto-darkening.
SENSITIVITY CONTROL
The sensitivity can be set to LOW or HIGH by
using the infinitely dial knob. The LOW setting
suits excess ambient light or with another wel-
ding machine close by. The HIGH setting suits
low amperage welding and welding in areas
with low light conditions, especially low am-
perage argon arc welding. Selections between
LOW and HIGH are suitable for most of indoor
and outdoor welding operations.
DELAY CONTROL
When welding ceases, the viewing window au-
tomatically changes from dark back to light but
with a pre-set delay to compensate. The delay
time can be set to MIN (0.1 sec) or MAX (1.0 sec),
by infinitely dial knob inside the cartridge. The
minimum delay suits spot or short welds. The
maximum delay suits heavy current welding
and reduces eye fatigue from the arc. Selections
between MIN and MAX are suitable for most of
indoor and outdoor welding operations.
MAINTENANCE
FRONT COVER LENS REPLACEMENT
Replace the front cover lens if it is damaged
(cracked, scratched, pitted or dirty). Remove the
old front cover lens by pressing two Lock Swit-
ches at the bottom of the Retaining Frame and
pull the frame and ADF out. Take the old front
cover lens out, and remove any protective film
before installing the new one.
INSIDE COVER LENS REPLACEMENT
Replace the inside cover lens if it is damaged
(cracked, scratched, pitted or dirty). Place your
CSS02
VIEWING AREA 92×42mm
CARTRIDGE SIZE 110×90mm
ARC SENSOR 2
UV/IR PROTECTION UP to shade DIN 16 at
all times
LIGHT STATE DIN 4 (Grind)
DARK STATE External variable sha-
de, DIN9-13
SENSITIVITY CONTROL Low-Mid-High adjus-
table
SWITCH TIME (LIGHT TO DARK) 1/15,000 s, from Light
to Dark
DELAY CONTROL (DARK TO
LIGHT) 0.1-1.0S, by infinitely
dial knob, from Dark
to Light
POWER SUPPLY Solar cell and
1×CR2450 non-re-
placement lithium
battery
TIG AMP RATING DC≥10, AC≥10
OPERATING TEMPERATURE -5°C to +55°C
STORING TEMPERATURE -20°C to +70°C