Teknim VAP404 Betriebsanleitung

VAP404
INSTALLATION & OPERATION MANUAL
Issue Date: 09/07/2013
Software version 3.0 and higher
TD-1/07-008

TD-1/07-008
2 / 83
SAFETY PRECAUTIONS
Read this guide carefully before operating device and keep this guide for later reference. Follow all
operating and safety instructions in this guide.
Keep devices away from dust and moisture.
Locate device to the straight place in order not to damage it.
Use device together with metal box .
OPERATING CONDITIONS :
Don’t operate device beyond following values.
Temperature : Between 0C and +65C
Humidity : %95 in +40C
POWER SUPPLY:
Use device only with voltage mentioned in guide. If you are not sure about supply voltage you will connect,
contact with your vendor.
GROUNDING :
Before connecting power supply, control if grounding works properly.
SUPPLY CABLE PROTECTION :
Protect the supply cable against breaking and crushing.
CURRENT LIMIT:
Don’t connect devices that consume current exceeds limits.
OBJECT and LIQUID ENTRY :
Never push any kind of objects or liquid into this unit as they may short-out parts that could result in a fire or
electrical shock.
SERVICE :
Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified service personnel.
CONDITIONS NEED SERVICE :
Contact with your vendor on the following conditions
oIf power cable or plug is damaged ,
oIf any kind of objects drops into unit ,
oIf unit is exposed to water or rain ,
oIf unit is dropped or cover is damaged ,
oIf you realize that device doesn't work properly
oIf unit doesn’t operate properly in operating conditions ,
SPARE PART :
If parts of device are changed to repair, ensure that technician uses original parts against electrical shock,
fire, etc.
SECURITY CONTROL :
To control if your device operates in healthy and convenient conditions, demand service from your vendor.

TD-1/07-008
3 / 83
TABLE OF CONTENTS
1. INTRODUCTION 5
2. FEATURES 6
3. MOUNTING
3.1. GENERAL 7
3.2. SIREN CONNECTION 8
3.3. DETECTOR CONNECTION 8
3.4. KEYPAD CONNECTION 12
3.5. TELEPHONE LINE CONNECTION 12
3.6. CONNECTING OF PROGRAMMABLE OUTPUTS 13
3.7. CONNECTION OF PANEL ARMED OUTPUT (ARM) 13
3.8. POWER CONNECTION 14
4. QUICK & SIMPLE PROGRAMMING
4.1. FIRST OPERATING 14
4.2. SIMPLE PROGRAMMING 14
5. PROGRAMMING SETTINGS
5.1. INTRODUCTION 17
5.2. ENTERING/EXITING INSTALLER & MASTER PROGRAM 18
5.3. CHANGING CODES 18
5.4. ASSIGNING/DISPLAYING KEYPAD ADDRESS 18
5.5. PROGRAMMING ADDRESSES 18
5.6. DEFAULT CONFIGURATIONS 26
6. LOADING FACTORY DEFAULTS 31
7. APPLICATIONS
7.1. SMART PARTITION TECHNOLOGY 32
7.2. ACCESS CONTROL 33
7.3. USING VAP PANEL AS TWO SEPERATED PANELS 33
7.4. CONNECTING FIRE DETECTOR 34
7.5. CONNECTING FIRE SIREN 34
7.6. AUTOMATIC ARM PARTTITONS ON NO ACTIVITY 34
7.7. ADDING REMOTE CONTROL MODULE 35
7.8. ADDING VOICE MESSAGE MODULE 35
7.9. CONNECTION OF VAPMAN SOFTWARE PC VIA COM PORT 35
7.10. CONNECTION OF VAPMAN SOFTWARE PC VIA USB PORT 35
8. DETAILED PROGRAMMING
8.1. MAIN CONFIGURATIONS
8.1.1. Time/Date Settings 36
8.1.2. Entry Delays 37
8.1.3. Exit Delays 37
8.1.4. Central Monitoring Station Account Numbers 38
8.1.5. Central Monitoring Station Phone Numbers 38
8.1.6. User Phone Numbers 39
8.1.7. Assigning/Changing User Codes 40
8.2. PANEL SETTINGS
8.2.1. Panel Main Settings 41
8.2.2. Siren Settings 44
8.2.3. Automatic Arm/Disarm Settings 44
8.2.4. PGM Output Settings 47
8.2.5. Timer Settings 49
8.2.6. Remote Controlling 51
8.2.7. Setting Zone as KEY Input 51
8.3. ZONE SETTINGS
8.3.1. Zone Wiring 52
8.3.2. Zone Partitions 53
8.3.3. Zone Types 54
8.3.4. Zone Extra Settings 55
8.3.5. Zone Trigger Delay 56
8.4. KEYPAD SETTINGS
8.4.1. Keypad Permissions 56
8.4.2. Keypad Partitions 57

TD-1/07-008
4 / 83
8.5. USER SETTINGS
8.5.1. Start Time 57
8.5.2. Finish Time 58
8.5.3. User Days 59
8.5.4. User Partitions 59
8.5.5. User Keypads 60
8.5.6. User Limitations 61
8.6. CENTRAL MONITORING STATION & USER PHONE DIALER SETTINGS
8.6.1. General Features 61
8.6.2. Event Logs 65
8.6.3. Contact ID Event Codes 68
8.6.4. DTMF 4+2, etc Event Codes 70
8.7. OPTIONAL MODULES
8.7.1. Remote Control Module 72
8.7.2. Zone Expansion Module 73
8.8 KEYPAD INNER SETTINGS
8.8.1. VPC108 LED Keypad Inner Settings 73
8.8.2. VPC301 LCD Keypad Inner Settings 74
9 . KEYPAD INSTRUCTION
9.1. LED KEYPAD-VPC108
9.1.1. Features 77
9.1.2. Usage 77
9.1.3. Functions of Buttons 78
9.1.4. Meaning of Beep Sounds 78
9.1.5. Meaning of Lights 79
9.1.6. Keypad Addresses 79
9.1.7. Keypad Inner Settings 79
9.1.8. Reports 79
9.1.9. Troubles 79
9.2. LCD KEYPAD VPC301
9.2.1. Features 80
9.2.2. Usage 81
9.2.3. Functions of Buttons 81
9.2.4. Meaning of Beep Sounds 82
9.2.5. Meaning of Lights 82
9.2.6. Keypad addresses 82
9.2.7. Keypad Inner Settings 82
9.2.8. Reports 82
9.2.9. Troubles 82

TD-1/07-008
5 / 83
1. INTRODUCTION
VAP404 is 4+4 zone alarm panel that meets desires. It has simple usage also let technician to configure user
needs simply.
Simple Mounting
oPanel is mounted wall by three holes.
oPanel case has cable holes to pass cables through Panel PCB.
oFunctions of terminals is written on PCB. Connect cables to proper place.
oConnect telephone lines
oConnect Battery and AC Power
Simple Maintenance
oDevice monitors troubles instantly.
oTest feature provides simple maintenance.
o256 events are hold in memory.
oBattery doesn’t need maintenance.
Simple Programming
oProgramming addresses are grouped by feature.
oInstaller can configure panel, only by setting user codes, phone numbers.
oAll settings can be configured or can be downloaded to computer, by using PC software and connection
cable,
Simple Usage
oSimply arm/disarm panel by entering code.
oSmart Partition Technology provides quick arming.
oArm/Disarm by Remote controller.
oArm/Disarm by Telephone
oArm/Disarm by Key.
oAutomatic Arm/Disarm feature by Timers.
Simple Automation
oWhen panel is armed, ARM output activates and can be used control anything.
oPGM outputs can be activated by timers.
oPGM outputs can be activated by assigned zones or partitions to PGMs.
oPGM outputs can be used as ARM or SRN output.
oPGM outputs can be activated on condition of fire or can be used to reset fire detectors.
oPGM outputs can be controlled by Telephone.
oPGM outputs can be controlled by Keypad.
Simple Management
oTime limit can be assigned to users
oUsers can arm specific partitions.
oUsers keypads can be selected.
Smart Partition Technology
oWithout creating partition , zones are assigned to partitions defined before. Doors are assigned to C
Button, windows are assigned to B Button, interior zones are assigned to A Button , exterior zones are
assigned to D Button.
oDoors are armed with C Button ,windows are armed with B button quickly.
oYou can arm zones except interior zones when you are in home by using A Button ,
oYou can fully arm panel by using D Button.

TD-1/07-008
6 / 83
2. FEATURES
Inputs
oProgrammable 4+4 zone
oNC,NO, 1-EOL Resistor, 2-EOL Resistor zones, Double Zone.
oDifferent zone types (Door, Window, Tamper, Fire etc.)
oAdditional features assigned zones(Follower zone, end zone, silent zone etc)
oEnter/Exit delays for each partition.
oKEY input to arm
oSabotage switch on Panel and Keypad
Outputs
oProgrammable outputs (NC, NO)
oSiren Output; SRN (NC, NO, cutoff time)
oARM Output (NC, NO)
Siren
oOutdoor or Indoor can be connected
oAdjustable cutoff time(2255 minutes)
Keypad
oCan be used with 4 Keypads(max)
oAddressable Keypads
oLED or LCD Keypads can be used together
oProgrammable backlight
oDisplays event logs
oDisplays Ready, Armed, Trouble, Fire status
oShortcut buttons like Test, Report, Memory.
oOnly displays zones assigned to Keypads
oChime option
oKeypad Dimensions: 150mm(width) x 120mm (Length) x 22mm (Height)
General Features
o5 user codes,1 Master code, 1 installer code, 1 Guest code, 1 Ambush code, 1 PC Connection Code
oReal time clock
o256 event logs
o6 user phone numbers
oCommunicator supports 2 Central Monitoring Stations (Contact ID, 4+2,4+1,3+2,3+1 (DTMF) )
oEach Central Monitoring Station has 2 phone numbers
oManuel and Automatic Bypass
oSmart Partition Technology
oPC connection by USB or COM Port
o2 Timers
oPGM outputs can be controlled by telephone
Types of Arming/Disarming Panel
oArm with single button
oArm/Disarm specific partitions
oAutomatic Arm/Disarm panel in the specific time.
oArm/Disarm with KEY Input
oArm/Disarm with remote control unit(Remote control module must be connected to Panel)
oArm/Disarm by telephone
Alarm Types
oSiren Alarm: siren alarms, panel dials user and Central Monitoring Station
oSilent Alarm: siren doesn’t alarm, panel dials user and Central Monitoring Station.
Electrical & Mechanical Features
o220230V AC Voltage
oFuse AC Voltage(125mA)
oPower supply for external units with electronic fuses
o12V DC Current Output(Siren + AUX + Keypad) : 1A (max)
oCurrent limited battery charge circuit
o2 x 12V 7Ah battery can be connected.
oPGM1, PGM2, ARM output current:: 300mA max. Total current output of PGM1,PGM2, ARM: 500mA max.
oSRN output current:: 500mA max.
oDimensions: 310mm(width) x 302mm (Length) x 83mm (Height)
oWeight( ± 2 gr) : 2785 gr / 3095 gr (Packaged)
Optional Modules
oVoice recording module, Voice message module (includes 8 messages), Remote Control module, 4-zone expansion module,
RS-232 PC link module, USB PC link module, Relay module, X-10 module, Network module, Modem module.

TD-1/07-008
7 / 83
3. MOUNTING
WARNING! : Don’t connect power to panel without finishing wiring.
3.1. GENERAL
Drill necessary holes on the wall and then mount panel case to wall by using proper holes. Metal cover of
panel constitute of body and cover. Cover is opened by removing two screws. Detectors, siren, and
telephone line are connected to Panel by using proper cables. (It is recommended to you use wire screened
cable or silver foiled LIYCY cable and ground the mains voltage) Before connecting supply voltage, make
sure that all connections are made correctly. Also it is recommended to connect keypad cable foil to panel
GND and keypad GND. For the mains voltage connection, 3x0.75 mm² standard cable may be
usedDescriptions of panel terminals are in the following picture.
Following picture shows panel connections.

TD-1/07-008
8 / 83
3.2. SIREN CONNECTION
Siren connection is made by 12V,SRN,GND terminals.12V and GND is supply voltage of Siren. Trigger
output of Siren is SRN. Siren output can be programmed as NO ,NC. If 2 sirens is connected, one of sirens
should be used in SCB mode.
When 2 sirens are connected to panel, one of the sirens should be on SCB mode to increase current
consumption.
3.3. DETECTOR CONNECTION
Detector alarm outputs are NC or NO. One of 2 wire output is connected to Z1, Z2 ,Z3 or ,Z4 input the other
is connected COM. Supply voltage of detectors is provided by AUX output. Z1, Z2, Z3, Z4 can be
programmed as NO,NC, single end of line resistor or double end of line resistor. Following picture shows
example of PIR detector and magnetic contact connection by using none end of line resistor connection.
End of Line Resistor Connection : When single end of line resistor is used, any break in detector cable
can be noticed. When double end of line resistor is used, any break in detector cable and also short circuit

TD-1/07-008
9 / 83
can be noticed. It is recommended to use double end of line resistor. 2.7kΩ resistor that comes with panel
can be used for end of line connection. These resistors should be connected to detector sides. If more than
one detector contacts is wanted to be serially connect, end of line resistor connection can’t be made, none-
resistor connection should be made. Following pictures shows end of line resistor connection.

TD-1/07-008
10 / 83
Zone number can be increased to 8 by zone doubling feature. You make zone doubling by using 1kΩ
and 2kΩ resistors connected to zone as following picture. Zone doubling is enabled in Zone Wiring section of
Installer Program. Each physical zone can be used as 2 zone by zone doubling. Contact types(NC,NO) of
zones can be configured from their addresses. Zone doubling feature can’t be used together with zone
expansion module.