Teledyne LXT-280 Bedienungsanleitung

Teledyne Analytical Instruments
OPERATING INSTRUCTIONS FOR
LXT-280
Dissolved Oxygen
Transmitter
DANGER
Toxic gases and or flammable liquids may be present in this monitoring system.
Personal protective equipment may be required when servicing this instrument.
Hazardous voltages exist on certain components internally which may persist
for a time even after the power is turned off and disconnected.
Only authorized personnel should conduct maintenance and/or servicing.
Before conducting any maintenance or servicing, consult with authorized
supervisor/manager.
P/N M
ECO:

LXT-280
Teledyne Analytical Instruments ii
Copyright © 2006 Teledyne Instruments/ Analytical Instruments
All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed,
stored in a retrieval system, or translated into any other language or computer language in
whole or in part, in any form or by any means, whether it be electronic, mechanical,
magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne
Instruments/ Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91749-
1580.
Warranty
This equipment is sold subject to the mutual agreement that it is warranted by us free from
defects of material and of construction, and that our liability shall be limited to replacing or
repairing at our factory (without charge, except for transportation), or at customer plant at
our option, any material or construction in which defects become apparent within one year
from the date of shipment, except in cases where quotations or acknowledgements provide
for a shorter period. Components manufactured by others bear the warranty of their
manufacturer. This warranty does not cover defects caused by wear, accident, misuse,
neglect or repairs other than those performed by TI/AI or an authorized service center. We
assume no liability for direct or indirect damages of any kind and the purchaser by the
acceptance of the equipment will assume all liability for any damage which may result from
its use or misuse.
We reserve the right to employ any suitable material in the manufacture of our apparatus,
and to make any alterations in the dimensions, shape or weight of any parts, in so far as
such alterations do not adversely affect our warranty.
Important Notice
This instrument provides measurement readings to its user, and serves as a tool by which
valuable data can be gathered. The information provided by the instrument may assist the user
in eliminating potential hazards caused by his process; however, it is essential that all
personnel involved in the use of the instrument or its interface, with the process being
measured, be properly trained in the process itself, as well as all instrumentation related to it.
The safety of personnel is ultimately the responsibility of those who control process
conditions. While this instrument may be able to provide early warning of imminent
danger, it has no control over process conditions, and it can be misused. In particular, any
alarm or control systems installed must be tested and understood, both as to how they
operate and as to how they can be defeated. Any safeguards required such as locks, labels,
or redundancy, must be provided by the user or specifically requested of TI/AI at the time
the order is placed.
Therefore, the purchaser must be aware of the hazardous process conditions. The purchaser
is responsible for the training of personnel, for providing hazard warning methods and
instrumentation per the appropriate standards, and for ensuring that hazard warning devices
and instrumentation are maintained and operated properly.
Teledyne Instruments/ Analytical Instruments, the manufacturer of this instrument, cannot
accept responsibility for conditions beyond its knowledge and control. No statement
expressed or implied by this document or any information disseminated by the
manufacturer or its agents, is to be construed as a warranty of adequate safety control under
the user’s process conditions.

Dissolved Oxygen Transmitter
Teledyne Analytical Instruments iii
Specific Model Information
Instrument Serial Number: _______________________
Instrument Range: _______________
Calibrated for: _______________

LXT-280
Teledyne Analytical Instruments iv
Safety Messages
Your safety and the safety of others is very important. We have
provided many important safety messages in this manual. Please read
these messages carefully.
A safety message alerts you to potential hazards that could hurt you
or others. Each safety message is associated with a safety alert symbol.
These symbols are found in the manual and inside the instrument. The
definition of these symbols is described below:
GENERAL WARNING/CAUTION: Refer to the
instructions for details on the specific danger. These cautions
warn of specific procedures which if not followed could cause
bodily Injury and/or damage the instrument.
CAUTION: HOT SURFACE WARNING: This warning is
specific to heated components within the instrument. Failure
to heed the warning could result in serious burns to skin and
underlying tissue.
WARNING: ELECTRICAL SHOCK HAZARD:Dangerous
voltages appear within this instrument. This warning is
specific to an electrical hazard existing at or nearby the
component or procedure under discussion. Failure to heed this
warning could result in injury and/or death from
electrocution.
Technician Symbol:All operations marked with this symbol
are to be performed by qualified maintenance personnel only.
NOTE: Additional information and comments regarding a
specific component or procedure are highlighted in the form
of a note.
CAUTION: THE ANALYZER SHOULD ONLY BE USED FOR THE
PURPOSE AND IN THE MANNER DESCRIBED IN
THIS MANUAL.
No
Symbol

Dissolved Oxygen Transmitter
Teledyne Analytical Instruments v
IF YOU USE THE ANALYZER IN A MANNER OTHER
THAN THAT FOR WHICH IT WAS INTENDED,
UNPREDICTABLE BEHAVIOR COULD RESULT
POSSIBLY ACCOMPANIED WITH HAZARDOUS
CONSEQUENCES.
This manual provides information designed to guide you through
the installation, calibration operation and maintenance of your new
process controller. Please read this manual and keep it available.
Occasionally, some instruments are customized for a particular
application or features and/or options added per customer requests.
Please check the front of this manual for any additional information in
the form of an Addendum which discusses specific information,
procedures, cautions and warnings that may be peculiar to your
instrument.
Manuals do get lost. Additional manuals can be obtained from
TI/AI at the address given in the Appendix. Some of our manuals are
available in electronic form via the internet. Please visit our website at:
www.teledyne-ai.com.

LXT-280
Teledyne Analytical Instruments vi
Table of Contents
List of Figures............................................................................ viii
List of Tables ............................................................................... ix
Introduction .................................................................................. 1
1.1 Overview 1
1.2 Main Features of the Transmitter 2
1.3 Optional Features 2
1.4 Front Panel 2
1.5 Model Identification 4
Installation .................................................................................... 5
2.1 Unpacking the Instrument 5
2.2 Mounting 5
2.3 Wiring 7
2.3.1 Site Wiring 7
2.3.2 Power Wiring 7
2.3.3 Sensor Wiring 8
2.3.4 DC Power 8
2.4 Configuring the LXT-280 9
2.5 Calibration 9
Operation .................................................................................... 11
3.1 Using the Front Panel Keys 11
3.2 Menus 12
3.2.1 Contrast 13
3.2.2 Main Menu 14
3.2.3 Electrode Data Screen 14
3.2.4 Electrode Zero Menu 15
3.2.5 Electrode Span Menu 16

Dissolved Oxygen Transmitter
Teledyne Analytical Instruments vii
3.2.6 Output Calibration Menu 16
3.2.7 DO Locus 16
3.2.8 Temperature Calibration Menu 17
Calibration ...................................................................................19
4.1 Calibration 19
4.2 Manual Output Mode 19
4.3 Contrast Adjustment 20
4.4 Zero Calibration 21
4.5 Span Calibration 22
4.6 Automatic Buffer Calibration 24
4.7 Calibration Error Detection 24
4.8 Back-to-Factory Calibration 25
4.9 Output Calibration 26
4.10 Locus Calibration 27
4.11 Temperature Calibration 27
4.11.1 Temperature Adjustment 27
4.11.2 Temperature Calibration—Manual TC Adjustment 28
4.11.3 Temperature Units Calibration – °C/°F Conversion 29
Calibration Correction Factors...................................................31
5.1 Calibration Correction Factors 31
5.2 Salinity Correction 34
5.3 Calibration Example 35
5.4 Grab Sample Calibration 35
5.5 Dissolved Oxygen Units of Measurement 36
Maintenance ................................................................................37
6.1 Routine Maintenance 37
6.1.1 Cleaning 37
6.1.2 Replacement of the Microprocessor: 37
Appendix .....................................................................................41
A.1 Specifications 41
A.2 Spare Parts Listing 43
Index ............................................................................................45

LXT-280
Teledyne Analytical Instruments viii
List of Figures
Figure 1-1: LXT-280 User Interface ................................................ 3
Figure 2-1: Typical Installation for the LXT-280 Transmitter............ 6
Figure 2-2: Intrinsically Safe Wiring Diagram .................................. 7
Figure 2-3: LXT-280 Wiring ............................................................ 8
Figure 3-1: LXT-280 Operator Interface........................................ 11
Figure 3-2: Available Menus ......................................................... 13

Dissolved Oxygen Transmitter
Teledyne Analytical Instruments ix
List of Tables
Table 5-1: Oxygen Saturation vs. Temperature.............................32
Table 5-2: Relative Humidity Correction Factors ...........................33
Table 5-3: Elevation Correction Factor..........................................33
Table 5-4: Salinity Correction Factor .............................................34
Table 6-1: Troubleshooting ...........................................................38

LXT-280
Teledyne Analytical Instruments x
DANGER
COMBUSTIBLE GAS USAGE
WARNING
This is instrument is Factory Mutual Approved as an
intrinsically safe and explosion proof gas analyzer for use in
Class I, II, and III Divisions 1 Groups A through G hazardous
areas. This approval applies only to the equipment specified
and installed in accordance with the information contained
within this manual. It is the customer's responsibility to
ensure safety especially when combustible gases are being
analyzed since the potential of gas leaks always exist.
The customer should ensure that the principles of operating
of this equipment is well understood by the user and that the
instrument as well as any approved support equipment is
properly installed. Misuse of this product in any manner,
tampering with its components, or unauthorized substitution
of any component may adversely affect the certification and
the safety of this instrument.
Since the use of this instrument is beyond the control of
Teledyne, no responsibility by Teledyne, its affiliates, and
agents for damage or injury from misuse or neglect of this
equipment is implied or assumed.
Inhaltsverzeichnis
Andere Teledyne Sender Handbücher
Beliebte Sender Handbücher anderer Marken

Dejero
Dejero EnGo 3x Bedienungsanleitung

Rosemount
Rosemount 4600 Bedienungsanleitung

Speaka Professional
Speaka Professional 2342740 Bedienungsanleitung

trubomat
trubomat GAB 1000 Bedienungsanleitung

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Bedienungsanleitung

Rondish
Rondish UT-11 Bedienungsanleitung