Telycam 20X NDI Bedienungsanleitung

TLC-300-IP-20-FNDI
20X NDI®PTZ Video Camera
User Manual
V1.0
(English)
J.BC.0205.0178


NDI®
— 1 —
CONTENTS
CONTENT.......................................................................................................................................................1
SAFETY GUIDES ...........................................................................................................................................2
PACKING LIST ..............................................................................................................................................3
QUICK START ............................................................................................................................................... 3
PRODUCT HIGHLIGHTS............................................................................................................................4
CAMERA SPEC ..............................................................................................................................................4
CAMERA INTERFACE.................................................................................................................................6
CAMERA DIMENSION................................................................................................................................ 6
IR REMOTE CONTROLLER......................................................................................................................7
VISCA IN (RS232 PORT). ............................................................................................................................. 9
VISCA PROTOCOL .....................................................................................................................................10
PELCO-D PROTOCOL...............................................................................................................................18
PELCO-P PROTOCOL ............................................................................................................................... 19
OSD MENU ................................................................................................................................................... 20
SET IP ADDRESS IN MENU ...................................................................................................................... 23
UVC CONTROL...........................................................................................................................................24
WEB SETTING ............................................................................................................................................ 25
NDI TOOLS GUIDE .................................................................................................................................... 31
VISCA OVER IP ...........................................................................................................................................33

NDI®
— 2 —
SAFETY GUIDES
1. Before operation, please fully read and follow all instructions in the manual. For your safety, always keep this
manual with the camera.
2. The camera power input range is 100-240V~AC(50-60Hz),ensure the power supply input within this rate before
powering on.
3. The camera power voltage is 12V DC, and the rated current is 2A. We suggest you use it with the original power
supply adapter supplied by the factory.
4. Please keep the power cable, video cable and control cable in a safe place. Protect all cables especially the
connectors.
5. Operational environment: -10℃~50℃, humidity less than 80%.To avoid any danger, do not put anything inside
the camera, and keep away from the corrosive liquid.
6. Avoid stress, vibration and damp during transportation, storage and installation.
7. Do not detect the camera housing and cover. For any service, please contact authorized technicians.
8. Video cable and control cable should be individually shielded, and cannot be substituted with other cables. Do
not direct the camera lens towards strong light, such as the sun or the intensive light.
9. Use a dry and soft cloth to clean the camera housing. Applied with neutral cleaning agent when there is need to
clean. To avoid damage on the camera lens, never use strong or abrasive cleaning agents on the camera housing.
10. Do not move the camera by holding the camera head. To avoid mechanical trouble, do not rotate the camera
head by hand.
NEVER MOVE THE CAMERA MANUALLY WHEN IT IS WORKING.
11. Put the camera on fixed and smooth desk or platform, avoid leaned installation.
12. Power Supply Polarity (Drawing)
Note:
The video quality may be affected by the specific frequencies of electromagnetic field.
Never grasp the head of the camera, and never move the camera by hand when it is working, otherwise,
mechanism maybe destroyed.

NDI®
— 3 —
PACKING LIST
Check all bellow items when open the package:
Camera········································································ 1
Power Adapter································································1
Power Cable·································································· 1
RS232 Control Cable························································ 1
USB Type-C Cable·························································· 1
Remote Controller··························································· 1
User Manual·································································· 1
Double-sided Adhesive······················································1
QC certification······························································ 1
QUICK START
1.Check all cable connections before power on.
2.Dial Switch Setting (at the bottom of the camera):
Dial Switch (ARM)
SW-1
SW-2
Instruction
1
OFF
OFF
Updating mode
2
ON
OFF
Debugging mode
3
OFF
ON
Undefined
4
ON
ON
Working mode

NDI®
— 4 —
PRODUCT HIGHLIGHTS
Equipped with the cutting-edge image processing solution, 1/2.8 inch 2.4MP sensor, providing
1080P60 full HD video resolution.
Big optical lens: 20x optical zoom , with 60 degree field of view.
Fast and precise focusing performance.
Supported field upgrade for ISP, ARM and FPGA.
HDMI, 3G-SDI, USB Type-C, NDI®output for various applications.
Support RS232/RS48/UVC control.
Daisy chain supported, max 7 cameras connected in VISCA protocol.
128 presets supported; Exposure parameter and white balance parameter can be saved in presets.
Support the standard UVC protocol, compatible with most of the video conferencing software.
Support Line in audio input.
Supports HDMI audio output.
Support the standard Sony VISCA over IP control interface, you can achieve remote control of
the camera through IP.
Support NDI®video transmission protocol, ultra-low latency, lossless transmission, interactive
control.
Support POE+ power supply, a network cable can solve all the functions of power supply, video
and control, while providing high-performance video encoding, video detail effect almost no
loss.
Provide multi-functional infrared remote control, support remote control one key to switch the
video format.
Support for setting IP address in the menu.
Multi-language menu: support Chinese, English, Russian.
CAMERA SPEC
Video Format
HDMI
1920*1080P60/59.94/50/30/29.97/25/24/23.98
1920*1080I60/59.94/50
1280*720P60/59.94/50/30/29.97/25
SDI
1920*1080P60/59.94/50/30/29.97/25/24/23.98
1920*1080I60/59.94/50
1280*720P60/59.94/50/30/29.97/25
Dial Switch
SW-3
SW-4
Instruction
1
OFF
OFF
Undefined
2
ON
OFF
Undefined
3
OFF
ON
Undefined
4
ON
ON
Undefined
Dial Switch
SW-5
SW-6
Instruction
1
OFF
OFF
Undefined
2
ON
OFF
Working mode
3
OFF
ON
Undefined
4
ON
ON
Undefined

NDI®
— 5 —
USB
Type-C
YUY2:1920*1080P6; 1280*960P10;
1280*720P13; 1024*768P16;
800*600P25; 640*480P30;
640*480P30
MJPG:1920*1080P30; 1280*960P30;
1280*720P30; 1024*768P30;
800*600P30; 640*480P30;
640*480P30
NDI®
1920*1080P60/59.94/50/30/29.97/25/24/23.98
1920*1080I60/59.94/50
1280*720P60/59.94/50/30/29.97/25
Video Interface
HDMI, SDI, USB Type-C, NDI®
Audio Interface
Line-in
Control Port
RS232, RS485, NDI
®
(VISCA over IP), USB Type-C(UVC1.1)
Network Speed
1000M
Video Bit Rate
6Mbps~135Mbps
Supported Protocol
HTTP, NDI, VISCA over IP, VISCA TCP, VISCA UDP, VISCA Serial,
PELCO-P, PELCO-D
POE+
Supported
Preset
Remote controller: 10; RS232: 128; Accuracy: 0.1°
Daisy Chain
Support RS232 serial daisy chain
Minimum Lux
0.1lux
White Balance
ATW/Manual/Auto/Indoor/Outdoor/Push
Exposure
Auto/Manual/Shutter/Iris/Bright
Focus
Auto/Manual
Iris
Auto/Manual
Electric Shutter
Auto/Manual
Gamma
Supported
WDR
Supported
BLC
Supported
2D Noise Reduction
Supported
3D Noise Reduction
Supported
Anti Flicker
OFF/50Hz/60Hz
Pan Tilt Flip
Supported
Input Voltage
DC12V/POE+(IEEE802.3at)
Working Temperature
-10℃~50℃
Working Humidity
≤80%
Dimension
220mm×190mm×173mm
Net Weight
1.45kg (3.2LBS)

NDI®
— 6 —
CAMERA INTERFACE
1. Camera Lens
6. Tripod Screw Hole
11. USB Type-C port
2. Camera Base
7. Installation Hole
12. HDMI port
3. IR Receiver Panel
8. RS232 control port (input)
13. SDI port
4. Power Indicator Light
9. RS232 control port(output)
14. NDI®port
5. Dial Switch
10. Line in port
15. DC12V plug
CAMERA DIMENSION(MM)

NDI®
— 7 —
IR REMOTE CONTROLLER
POWER
Under normal working mode, short press POWER key, to enter standby
mode;
Press it again, the camera will start configuration. and go back to HOME
position.
It will go to preset position if power on model has been set before.
FREEZE
Short press FREEZE key to freeze/ unfreeze the image.
IRT (IR Transfer/IR Pass)
Open / close the IR pass function. Once press the IRT key, the camera will
receive and pass the IR remote control signal to the codec/terminal (via
VISCA IN port).
SET 1~SET4 ADDRESS SETTING
Long press for 3seconds until the key light ON, to set camera address.
CAM1~CAM4(CAMERA SELECTING)
Short press to select the relative camera.
NUMBER KEY (1-9)
Set preset: long press (3 seconds) the number key to set preset.
Run preset: Short press the number key to run preset.
CLR PRE (CLEAR PRESET)
CLR PRE+ number key: to clear the relative preset.
Long press to clear all preset.

NDI®
— 8 —
FOCUS KEY ( ON THE LEFT)
Manual focus, only valid under manual focus model.
ZOOM KEY( ON THE RIGHT SIDE)
Set the zoom in or zoom out.
NAVIGATE KEY: UP/DOWN/LEFT/RIGHT
Under working mode, use navigate key to set the pan tilt, and select menu when enter OSD.
OK /HOME KEY
Under working mode, short press OK to make the camera go back to HOME position; and confirm the selection
when enter OSD.
AF: Auto Focus
MF: Manual Focus
RESET: Press 3 seconds to reset camera
MENU: Enter OSD menu
LEARN+LIMIT L key:Set the pan tilt left limit position.
LEARN+LIMIT R key:Set the pan tilt right limit position.
LEARN+LMT CLR key:Clear the limit position.
BLC OFF/ BLC ON:Not Available
BRIGHT-/BRIGHT+: Set image brightness, only valid under bright priority exposure mode.
Video Format Keys:
Long press 3 seconds to select different video format output.
Inhaltsverzeichnis
Andere Telycam Sicherheitskamera Handbücher

Telycam
Telycam Vision+N330X Bedienungsanleitung

Telycam
Telycam TLC-1000-DS Bedienungsanleitung

Telycam
Telycam TLC-600-S Bedienungsanleitung

Telycam
Telycam Vision+N320X Bedienungsanleitung

Telycam
Telycam Vision+4KN30X Bedienungsanleitung

Telycam
Telycam TLC-300-IP-20NDI Bedienungsanleitung

Telycam
Telycam TLC-700-H Bedienungsanleitung

Telycam
Telycam TLC-300-IP-12 Bedienungsanleitung

Telycam
Telycam TLC-700-S Bedienungsanleitung

Telycam
Telycam TLC-100-HU2-10 Bedienungsanleitung