Temspec VUD Series Handbuch

Operation & Maintenance Manual
VUD, VUF, VDF & HCD Series
Unit Ventilator
© 2006 TEMSPEC INCORPORATED
IMPORTANT: Read and save this manual for future reference.
This manual is to be left with the equipment owner

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[1]
Table of Contents
INTRODUCTION
About the Unit Ventilator ….……………………………………………………………………2
Nomenclature for non-compressorized Unit Ventilators ………….……………………2
TYPICAL UNIT LAYOUT
Model VUD 1200 ……………………………………………………….………………………3
Model VUD 1600 ……………………………………………………….………………………4
Model VUD 2000 ……………………………………….………………………………………5
Model VUF 1200 ……………………………………………………….………………………6
Model VUF 1500 ……………………………………………………….………………………7
Model VDF 1200 ……………………………………………………….………………………8
Model HCD 1200 ……………………………………………………….………………………9
Model HCD 1600 ……………………………………………………….………………………10
OPERATION
Sequence Of Operation .………………………………………………………………………11
Hot Water Circuit .……………………………………………………………………………...12
Refrigeration Circuit………....……………………………………………………………….……13
Electrical Circuit ……….….…………………………………………………………………..14
Dampers ……….………….…………………………………………………………………..14
Filtration ……….………….………………………………………………………………......14
MAINTENANCE
Servicing the Unit ………….………….………………………………………………………..15
Maintenance Schedule ….………….……………………………………………………..…15
Changing the Filters………….………….……………………………………………………..…16
Cleaning the Evaporator Coil …….………………………………………………………...16
Motors ………………………….…………………………………………………………...16
TROUBLESHOOTING
Basic Troubleshooting Guidelines…..…………………………………………………………..17
REPLACEMENT PARTS
Limited Warranty ..……………………...………………………………………………………18
Parts Sales …………..………………………..…….…………………………………………....18

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[2]
INTRODUCTION
The Temspec unit ventilator is designed as means for providing heating, cooling and
ventilation to the classroom. Our goal is to help create an enhanced learning environment
by focusing on the following points when designing our equipment:
•COOLING, HEATING, HUMIDITY AND VENTILATION
CONTROL
•AIR DISTRIBUTION
•SOUND ATTENUATION
By installing the vertical unit ventilator into the classroom, superior control can be obtained
for each room. Because the unit can be ducted, an even distribution of air can be achieved
throughout the room. The unit ventilator is constructed with heavy gauge metal and sound
absorbing insulation for optimal sound attenuation.
By applying sound engineering principles and thorough testing, we ensure the highest
quality of performance in our unit ventilators.
ABOUT THE UNIT VENTILATOR
NOMENCLATURE FOR NON-COMPRESSORIZED UNIT VENTILATORS
V=Vertical Unit
H=Horizontal
UD = Upflow Ducted Unit Ventilator
UF = Upflow Freeblow (direct discharge) Unit Ventilator
CD= Horizontally Ducted Unit Ventilator
DF= Downflow Unit Ventilator
1200 = up to 1200 cfm
1500 = up to 1500 cfm
1600 = up to 1600 cfm
2000 = up to 2000 cfm
1200
UD
V

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[3]
TYPICAL LAYOUT
CW
O.A. Outdoor Air
1. Supply air fan.
2. Hot water coil. Optional electric or steam
coil available.
3. DX cooling coil.
4. Drain pan.
5. Outdoor air damper.
6. Spring return mixed air damper actuator.
7. Filters.
SIDE SECTION
(Hot Water /
Chilled Water)
SIDE SECTION
(Split System DX)
6
S.A. Supply Air
21.5"
R.A.
8
21.5"
O.A.
5
4
3
2
1
7O.A.
9
HW
S.A.
8. Return air damper.
9. 2 pipe or 4 pipe (hot water coil can be
in the reheat position).
10. Ceiling tile.
11. Top extension (optional).
12. Coil access panel.
13. Hinged filter access panel.
14. Heavy duty return air grille.
FRONT ELEVATION
14
R.A.
R.A. Return Air
28"
Duct By
Others
10
11
12
13
4
S.A.
93"
H
NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied.
Model VUD 1200 (Upflow, Ducted Configuration)

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[4]
TYPICAL LAYOUT
CW
O.A. Outdoor Air
1. Supply air fan.
2. Hot water coil. Optional electric or steam
coil available.
3. DX cooling coil.
4. Drain pan.
5. Outdoor air damper.
6. Spring return mixed air damper actuator.
7. Filters.
SIDE SECTION
(Hot Water /
Chilled Water)
SIDE SECTION
(Split System DX)
6
S.A. Supply Air
23"
R.A.
8
23"
O.A.
5
4
3
2
1
7O.A.
9
HW
S.A.
8. Return air damper.
9. 2 pipe or 4 pipe (hot water coil can be
in the reheat position).
10. Ceiling tile.
11. Top extension (optional).
12. Coil access panel.
13. Hinged filter access panel.
14. Heavy duty return air grille.
FRONT ELEVATION
14
R.A.
R.A. Return Air
33"
Duct By
Others
10
11
12
13
4
S.A.
93"
H
NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied.
Model VUD 1600 (Upflow, Ducted Configuration)

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[5]
TYPICAL LAYOUT
O.A. Outdoor Air
S.A.
8
5
S.A. Supply Air
1. Dual supply air fans.
2. DX cooling coil.
3. Filters.
4. Spring return mixed air damper actuator.
5. Outdoor air damper.
6. Hot water coil. Optional electric or steam
coil available.
7. Drain pan.
SIDE SECTION
(Split System DX)
O.A.
23"
O.A.
R.A.
SIDE SECTION
(Hot Water /
Chilled Water)
23"
4
1
2
3
9
7
6CW
HW
S.A.
R.A. Return Air
8. Return air damper.
9. 2 pipe or 4 pipe (hot water coil can be
in the reheat position).
10. Ceiling tile.
11. Top extension (optional).
12. Coil access panel.
13. Hinged filter access panel.
14. Heavy duty return air grille.
FRONT ELEVATION
R.A. 14
44"
13
12
11
10
Duct By
Others
93"
H
NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied.
Model VUD 2000 (Upflow, Ducted Configuration)

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[6]
TYPICAL LAYOUT
O.A. Outdoor Air
SIDE SECTION
(Hot Water /
Chilled Water)
S.A. Supply Air
1. Hot water coil. Optional electric or steam
coil available.
2. DX cooling coil.
3. Drain pan.
4. Supply air fan.
5. Outdoor air damper.
6. Spring return mixed air damper actuator.
7. Filters.
SIDE SECTION
(Split System DX)
21.5"
R.A.
21.5"
3
5
6
O.A.
4
1
2
O.A.
7
8
S.A.
9
HW
CW
R.A. Return Air
8. Return air damper.
9. 2 pipe or 4 pipe (hot water coil can be
in the reheat position).
10. Double deflection supply air grille.
11. Coil access panel.
12. Hinged filter access panel.
13. Heavy duty return air grille.
FRONT ELEVATION
13
R.A.
28"
10
11
12
3
S.A. S.A.
93"
S.A.
NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied.
Model VUF 1200 (Upflow, Freeblow Configuration)

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[7]
TYPICAL LAYOUT
S.A.
O.A. Outdoor Air
R.A.
S.A. Supply Air
1. DX cooling coil.
2. Dual supply air fans.
3. Filters.
4. Spring return mixed air damper actuator.
5. Outdoor air damper.
6. Hot water coil. Optional electric or steam
coil available.
7. Drain pan.
SIDE SECTION
(Split System DX)
O.A.
23"
O.A.
R.A.
SIDE SECTION
(Hot Water /
Chilled Water)
23"
4
2
1
3
58
7
6
S.A.
9
HW
CW
R.A. Return Air
8. Return air damper.
9. 2 pipe or 4 pipe (hot water coil can be
in the reheat position).
10. Double deflection grilles.
11. Coil access panel.
12. Hinged filter access panel.
13. Heavy duty return air grille.
FRONT ELEVATION
13
44"
12
11
10
S.A.
93"
S.A.
NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied.
Model VUF 1500 (Upflow, Freeblow Configuration)

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[8]
TYPICAL LAYOUT
HW
O.A. Outdoor Air
SIDE SECTION
(Hot Water /
Chilled Water)
CW
SIDE SECTION
(Split System DX)
1. Return Air damper.
2. Outdoor air damper.
3. Supply air fan.
4. Hot water coil. Optional electric or
steam coil available.
5. Spring return mixed air damper actuator.
6. Filters.
7. Slab type DX cooling coil.
S.A. Supply Air
21.5"
8
7
21.5"
4
3
2
O.A.
1
6
5
R.A.
9
O.A.
8. Drain pan.
9. 2 pipe or 4 pipe (hot water coil can be
in the reheat position).
10. Heavy duty return air grille.
11. Hinged filter access panel.
12. Coil access panel.
FRONT ELEVATION
8
R.A. Return Air
S.A.
28"
S.A.
11
12
10
R.A.
93"
NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied.
Model VDF 1200 (Downflow Configuration)

Operation and Maint.Manual VUD VUF VDF HCD SeriesRev6.doc
[9]
TYPICAL LAYOUT
SIDE SECTION
O.A.
O.A. Outdoor Air
93"
Duct By
Others
OPTIONAL TOP O.A.
INTAKE DETAIL
1. Outdoor air damper.
2. Spring return mixed air damper actuator.
3. Return air damper.
4. Filters.
5. Heavy duty return air grille or duct collar.
6. Split DX or hot water/chilled water coil
(2 pipe or 4 pipe).
7. Drain pan. Drain pan is removable when
option for bottom access panels is selected.
R.A.
S.A. Supply Air
3
Duct By
Others
O.A.
31
1O.A.
5
R.A.
42
10" x 12"
Supply Air
Opening
ISOMETRIC VIEW
(shown with left side access panel)
8. Hot water coil for spilt system DX or heating
only units. Optional steam and electric
heater also available.
9. Supply air fan.
10. Mounting brackets (4 per unit).
11. Left or Right side hinged filter access panel.
Bottom hinged access panel also available.
12. Left or Right side hinged coil access panel.
Bottom hinged access panel also available.
R.A.
10
11
R.A. Return Air
12
10
28"
Duct By
Others
7 9
Optional
O.A. intake
location
6 8
Suspension
Rods By
Others
S.A. 21.5"
NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied.
Model HCD 1200 (Horizontal Configuration)
Dieses Handbuch passt für folgende Modelle
11
Inhaltsverzeichnis
Andere Temspec Lüfter Handbücher