thermastor Phoenix Bedienungsanleitung

Owner’s Manual — Phoenix Centrifugal Air Mover
Installation, Operation & Service Instructions
1
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
Read and Save These Instructions
Phoenix Centrifugal Air Mover
TS-350
Phoenix Centrifugal Air Mover
• 3-Speed 1/3 Horsepower Motor
3.9 Amps on High Speed
2.6 Amps on Medium Speed
2.45 Amps on Low Speed
• Maximum Velocities Over 2950 FPM
• Best Balanced Exhaust Airflow
• Stackable
• Directional Airflow
Horizontal
45° Angle
90° Angle
Low amp draw, balanced airflow characteristics and
maximum velocities of over 2950 FPM are what propel the
Phoenix to rise above the competition.
The unique 1/3 horsepower design of the Phoenix
Centrifugal Air Mover, coupled with a three-speed switch,
allows the restoration technician to deliver the most airflow
using the fewest amps.
Maximum amp draw on high speed is 3.9 amps. This
drops to a mere 2.45 amps on low speed. It is now
possible to fit as many as four Phoenix Centrifugal Air
Movers onto a typical 15 amp household circuit.
The Phoenix housing is durable, washable, and chemical
resistant. Phoenix Centrifugal Air Movers are also
stackable. In addition, molded-in runners allow for the air
mover to be angled up from horizontal to 45° and 90°.
Specifications subject to change without notice.
Revised 1/07
Phoenix Centrifugal Air Mover
PN 4025825
PO Box 8680 • Madison, WI 53708

2
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
1 Safety Information
When using any electrical device basic precautions should
always be followed, including the following:
• Do not operate unit with a cut or frayed power cord.
Replace cord if it becomes damaged.
• Handle with care. Do not drop or throw the unit. The unit
can be damaged under harsh treatment.
• Do not unplug the unit by pulling on the cord. Grasp the
plug firmly and pull it out of the wall socket or power
receptacle.
• Always use a grounded outlet.
• Never operate electrical equipment in standing water.
• Never operate with the safety grills removed. Personal
injury may result.
• Do not stick your fingers or other objects through the
safety grills.
• Do not restrict airflow to the unit. This may cause the
unit to overheat.
• Unit should never be serviced or cleaned while it is
plugged in.
• Make sure the unit is secure, stable and safe from
falling over or falling down before operating.
• Do not sit or stand on the unit or use as a shelf.
• Ensure children do not have access to the equipment.
Do not allow children to play with or near the unit or in
its air flow.
• To reduce the risk of fire or electric shock, do not use
this air mover with any solid-state speed control device.
• Do not leave device plugged in when not in use.
• Dot not expose to rain–store indoors.
• Use only as described in this manual.
• Use only Manufacturer’s recommended attachments.
Contact Therma-Stor for proper repair instructions.
Table of Contents
Introduction ................................................................1
1. Safety Information .................................................1
2. Specifications........................................................2
3. Operation .............................................................3
4. Troubleshooting ....................................................3
5. Warranty...............................................................5
Purchase Date ______/______/_____
Dealer’s Name ___________________________________
• Never operate units when stacked. Stacking is for
transport and storage only.
• Do not pull or carry by cord, use cord as a handle, close
doors on cord or pull cord around sharp edges.
• Do not run over cord.
• Keep cord away from heated surfaces.
• Do not handle plug with wet hands.
• Turn off all controls before unplugging.
• Do not use when you are tired, distracted or under the
influence of drugs, alcohol or medication.
2 Specifications
Part No. 4025825
Power 115 VAC, 60 hz.
Operating 3
Positions
Drive Motor 1/3 Horsepower, 3-Speed
Thermal Thermal cut-off
Protection
Stackable: Yes
Cord Length 20 Feet
CFM Approximately 3000
Outlet 15A UL Rated GFCI Duplex Receptacle
Current Draw 2.5 Amps
Warranty Year One - 100% parts and labor (all com-
ponents)
Year Two - 100% parts only (all compo-
nents)
Year Three - Only materials and
workmanship of the housing are covered.
SPEED RPM CFM AMPS
High 1050 2200 3.9
Medium 850 1800 2.60
Low 650 1500 2.45
Dimensions
Machine Shipping
Width 16.5” 18.75”
Height 18” 22”
Depth 18” 20.5”
Weight 28 Lbs 29 Lbs

3
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
3 Operation
The Phoenix Centrifugal Air Mover features a four-position
switch - OFF, HIGH, MEDIUM, LOW.
1. Check the unit for airflow obstructions prior to plugging
in the unit or operation.
2. Place the machine into the desired position for
operation.
3. Plug the power cord into a GFCI protected outlet. Do
not use an extension cord in conjunction with the
standard power cord.
4 Troubleshooting
Symptom: Unit will not turn on
Problem: Not plugged in; Switch is worn; Tripped wall
circuit breaker; Short in power cord; Capacitor on motor is
worn.
Solution: Plug machine into proper outlet; Replace switch.
Reset breaker; Replace power cord or replace cord end;
Replace motor.
Symptom: Air mover will not operate on all speeds.
Problem: Switch is worn; Capacitor on motor is worn.
Solution: Replace switch; Replace motor.
Symptom: Fan is rubbing.
Problem: The fan is out of round.
Solution: Replace fan.
Symptom: Air mover is making strange noises.
Problem: There is an obstruction; Motor bearing is worn.
Solution: Turn off motor and remove obstruction; Replace
motor.

4
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
This page intentionally left blank.

5
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
Phoenix Centrifugal Air Mover Limited Warranty
Warrantor:
Therma-Stor LLC
PO Box 8680
Madison, WI 53708
Telephone: 1-800-533-7533
Warranty: This warranty covers Phoenix Centrifugal Air Movers
First Year Warranty: - 100% parts and labor (all components)
Second Year Warranty: - 100% parts only (all components)
Third Year Warranty: - Only materials and workmanship of the housing are covered.
If a defect in materials or workmanship occurs within the warranty period, Therma-Stor LLC will repair
or replace the defect.
End-User Responsibilities: Warranty service must be performed by a servicer authorized by Therma-
Stor LLC. To obtain warranty service you must obtain a return material authorization (RMA). To obtain
an RMA you must present proof of purchase or (lease), by use of a warranty card, original sales
receipt or other reasonable and reliable means. To obtain an RMA call Therma-Stor LLC at the above
number and ask for the Therma-Stor LLC Service Department, which will then issue an RMA# and
arrange for, at our option, either repair or replacement.
Freight: Freight to and from the servicer is the responsibility of the end-user. The end-user is
responsible for normal care and proper return packaging.
Limitations and Exclusions: This warranty does not cover any defect, malfunction, etc. resulting from
misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or
improper repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC’s
reasonable control.
If any Phoenix Centrifugal Air Mover part is repaired or replaced, the new part shall be warranted for
the balance of original warranty (but all warranty periods will be extended by the period of time, if any,
that the Phoenix Centrifugal Air Mover is out of service while awaiting covered warranty service).
Warranty service will be performed during normal working hours.
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX CENTRIFUGAL
AIR MOVER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL
WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE
AGAINST THERMA-STOR BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC,
IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY PHOENIX
CENTRIFUGAL AIR MOVER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY
SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE
(THE END USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF
USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not allow
the exclusion or limitation of incidental or consequential damages, so one or both of these limitations
may not apply to you.
Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere thermastor Lüfter Handbücher

thermastor
thermastor Ultra-Aire 120V Bedienungsanleitung

thermastor
thermastor 4025200 Bedienungsanleitung

thermastor
thermastor Quiet-Vent Ventilation System Bedienungsanleitung

thermastor
thermastor Phoenix TS-285 Bedienungsanleitung

thermastor
thermastor Phoenix AirMax Bedienungsanleitung

thermastor
thermastor Phoenix AirMAX Bedienungsanleitung