WARNINGS
This manual should be kept even after installation of the
product.
This device is not intended for use by persons (includ-
ing children) with physical, sensory or mental disability,
or by persons lacking experience or knowledge, unless
they have received adequate supervision or preliminary
instructions on how to use the device from a person in
charge of their safety.
Children should be supervised to ensure that they do not
play with the appliance.
This unit can be used by children of not less than 8 years
and people with reduced physical, sensory or mental capa-
bilities or without experience or knowledge it they are pro-
perly supervised or if the instructions for using the device
safely have been given and if the risks are tacking into
account. Children must not play with the device. Cleaning
and maintenance must not be done by children without
supervision.
INSTALLATION:
WARNING: Heavy unit, handle with care:
1/ Install the appliance in a frost-protected room. If the
appliance is damaged due to the blockage of the safety
unit, the warranty will not apply.
2/ Make sure the wall on which the appliance is mounted
3/ If the appliance is to be installed in a room or location
where the ambient temperature is constantly higher than
1
Warnings Warranty Use Servicing
EN

4/ When set up in a bathroom, do not
install the appliance in areas V0, V1
and V2. If the dimensions do not facili-
tate any alternative, installation in area
V2 is permissible.
5/ The device is not intended to be used in altitudes
exceeding 2000 meters.
6/ Place the unit in a location with easy access.
section.
heating element’s replacement, allow at least 300 mm for
units up to 100 l and 480 mm for units of higher volumes,
-
er’s pipes. The clearance required for the appliance’s cor-
The vertical water heater on the base must (in accord-
using a fastening system intended for this purpose.
HYDRAULIC CONNECTION:
freezing and in accordance with local standards must be
installed on the inlet of the water heater.
A pressure reducing equipment (not supplied) placed on
the main water supply is required if the water supply pres-
sure exceeds 0.5 MPa (5 bar).
Connect the safety unit to a discharge pipe, kept in the
open air, in a frost-free environment, continuously sloping
2
Warnings Warranty Use Servicing

allow for drainage of the water heater.
If the appliance is set up on a false ceiling, the attic or
above living space, a drain pan is to be installed under-
neath the water heater. A drainage connected to the sewer
system is required.
ELECTRICAL CONNECTION:
to prevent any injury or electric shock risk.
Upstream of the appliance, the electrical installation must
have an all-pole cut-out device (circuit-breaker, fuse) in
accordance with the applicable local installation rules (30
mA earth-leakage circuit-breaker).
Please observe the wiring diagram on the back of the
cover.
Always connect the earth conductor of the cable to the
earth ground wire or connect the earth conductor to the
MAINTENANCE – SERVICING - TROUBLESHOOTING:
open the hot water faucets and then open the drain valve
of the safety unit.
The drainage system of the pressure reducing device
should be operated periodically (at least once a month)
to eliminate limescales and ensure that it is not blocked.
If the power cable is damaged, it must be replaced by the
manufacturer, its customer service or a professional with
The operating instructions for this appliance can be
obtained from the customer service. 3
Warnings Warranty Use Servicing
EN

WARRANTY
1. Scope of the Warranty
This warranty does not cover malfunctions due to:
Abnormal environmental conditions:
Various damages caused by shocks or falls during handling after leaving the factory.
Installing the appliance in a location subject to freezing or bad weather (moist, harsh
environment or poorly ventilated).
water (chlorides, sulphates, calcium, resistivity and TAC).
Water with a Th <8° f (total hardness)
Water pressure above 0.5 MPa (5 bar).
main supply, lightning...).
Damages resulting from problems that could not be detected due to the choice of the
installation location () and which could have been avoided by immedi-
ate repair of the appliance.
An installation that is not in compliance with regulations, standards and best prac-
tices, including:
The safety unit was removed or not functioning (
).
No safety unit or incorrect installation of a new safety unit in compliance with the NF
EN 1487 standard, change of its calibration…
No sleeves () on hot water connection pipes which could
lead to corrosion.
Faulty electrical connection: not in compliance with NFC 15-100, improper ground-
-
ure to comply with the wiring diagrams as recommended by the manufacturer.
Positioning the appliance not in compliance with the instructions in the operating
manual.
External corrosion due to poor water tightness of the piping.
Installation of a domestic hot water recirculation system.
Incorrect settings.
Cooling lines non-compliant with our recommendations (phases, length, or drop).
Improper maintenance:
Abnormal scaling of heating components or safety units.
No maintenance of the safety unit resulting in overpressure.
No cleaning of the evaporator and condensate drainage.
Alteration of the original equipment, without contacting the manufacturer or using
spare parts not referenced by the manufacturer.
Warnings Warranty Use Servicing
4

EN
An appliance with suspected damages must remain at the location available to
the expert, the owner must inform his insurer.
2. Conditions of warranty
-
ing practices, applicable standards and the recommendations of our technical services.
It shall be used in normal conditions and regular maintenance shall performed by a
specialist.
In these conditions, our warranty shall apply by exchanging or providing free of charge to
our Distributor or Installer the parts recognized as defective by our services, or if applica-
ble, the appliance, excluding labor and transportation costs, as well as any extension of
warranty.
), in the absence of proof, the date taken into account shall be the manufacture
date indicated on the rating plate of the water heater with a six-month extension.
The warranty for the replacement part or water heater () shall end at the
same time as the warranty for the part or the water heater that was replaced. .
PLEASE NOTE: Any costs or damages due to faulty installation (
not be attributed to the manufacturer.
the advantages of the legal warranty for hidden faults and defects which apply in any case
pursuant with articles 1641 et seq. of the Civil Code.
A component failure does not justify the replacement of the unit. The defective part
will be replaced.
The supply of the spare parts essential to the use of our products is ensured for a period
of 7 years from the date of manufacture of the parts.
DISPOSAL:
The combustion of some components may release toxic gases, do not incinerate
the unit.
At the end of life, the unit must be brought to an electrical and electronic equip-
-
ing waste collection centers, contact the local collection service.
The refrigerant in the appliance must not be released in the environment. Any
degassing operation is strictly forbidden.
5
Warnings Warranty Use Servicing

CONTENT
USE ............................................................................................................................7
Operating principle ......................................................................................................7
Control panel ...............................................................................................................8
Indications ....................................................................................................................8
Menu.............................................................................................................................
BOOST function .........................................................................................................10
Operation Modes........................................................................................................11
SERVICING..............................................................................................................12
Information for the user ..............................................................................................12
Servicing.....................................................................................................................12
Menu service engineer (Access to standby Mode).....................................................
Troubleshooting..........................................................................................................20
Returning the refrigerant to the external aggregate....................................................27
Customer service........................................................................................................28
.............................................................................................................30
Declaration of conformity............................................................................................32
Warnings Warranty Use Servicing

7
Warnings Warranty Use Servicing
EN
USE
Operating principle
The thermodynamic water heater uses outside air to prepare domestic hot water.
pump will go through a thermodynamic
cycle which will allow the transfer of
energy from the outside air to the boiler.
evaporator. As it passes through the evap-
The compressor will compress vapors
-
ture. This heat will be transmitted through
the condenser wrapped around the tank,
heating the water in the tank.
-
static expansion valve, where it will cool down and regain its liquid form. It will then be
ready to receive heat again in the evaporator.
Unité extérieure Chauffe-eau
Ventilateur
Fan Tank
Condenser
Compressor
Evaporator
Expansion valve
External aggregate Water heater
AIR

Control panel
Mode selection
and operating
settings
Gradual increase
of hot water
production
Information
Instructions
Increase/navigate
Reduce/navigate
Back
06 :46
MANUAL ECO
Hot water quantity
setting
Indications
Amount of hot water Electric heating element
working.
Saved compulsory
activation. Heat pump working.
Absence saved.
Current absence. Waiting time.
Anti-legionella-cycle.
Warnings Warranty Use Servicing
8
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Sprachen:
Andere Thermor Boiler Handbücher
Beliebte Boiler Handbücher anderer Marken

Kenmore
Kenmore 153.582400 Bedienungsanleitung

Applimo
Applimo Edel AIR Bedienungsanleitung

STIEBEL ELTRON
STIEBEL ELTRON Eltronom SHU 5 S Bedienungsanleitung

clage
clage E-Mini Series Bedienungsanleitung

Toyotomi
Toyotomi Oil Miser OM-180 Bedienungsanleitung

Bradford White
Bradford White EF Series Bedienungsanleitung