7
7. MAINTENANCE
There are two ways to remove collected water.
1. Use the bucket
• When the unit is off,if the bucket is full, the Full indicator light will light.
• When the unit is on,if the bucket is full, the compressor and the fan turn
off, and the Full indicator light will light, the digital display shows P2.
• Slowly pull out the bucket. Grip the left and right handles securely, and
carefully pull out straight so water does not spill. Do not put the bucket
on the floor because the bottom of the bucket is uneven. Otherwise the
bucket will fall and cause the water to spill.
• Throw away the water and replace the bucket. The bucket must be in
right place and securely seated for the dehumidifier to operate.
• The machine will re-start when the bucket is restored in its correct position.
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied, or when the bucket is
removed or not replaced in the proper position.
Auto Shut OFF
The dehumidifier huts off when the bucket is full, or when the bucket is
removed or not replaced in the proper position.When the setting humidity
is reached, the unit will be shut off automatically. For some models,the fan
motor will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart opertation in the first 3
minutes. This is to protect the unit. Operation will automatically start after
3 minutes.
Check filter feature
The system starts to count the time once the fan motor operates. The
check filter feature can be only activated when the accumulated operation
time achieves 250 hours or more. The Reset light(Clean filter indicator light)
flashes at one time per second, after finishing clean the air filter, press the
Filter pad and the Reset light(Clean filter indicator light) goes off.
Auto-Restart(on some models)
If the unit breaks off unexpectedly due to the power cut, it will restart with
the previous function setting automatically when the power resumes.
Setting the Timer
• When the unit is on, first press the Timer button, the Timer Off indicator
light illuminates. It indicates the Auto Stop program is initiated. Press it
again the Time On indecator light illuminates.It indicates the Auto Start is
initiated.
• When the unit is off, first press the Timer button, the TIMER ON indicator
light illuminates. It indicates the Auto Start program is initiated. Press it
again the Time Off indecator light illuminates.It indicates the Auto Stop is
initiated.
• Press or hold the UP or DOWN pad to change the Auto time by 0.5 hour
increments, up to 10 hours, then at 1 hour increments up to 24 hours. The
control will count down the time remaining until start.
• The selected time will register in 5 seconds and the system will
automatically revert back to display the previous humidity setting.
• When the Auto start & Auto stop times are set, within the same program
sequence, TIMER ON OFF indicator lights illuminate identifying both ON
and OFF times are now programmed.
• Turning the unit ON or OFF at any time or adjusting the timer setting to
0.0 will cancel the Auto Start/Stop function.
• When LED display window displays the code of P2, the Auto Start/Stop
function will also be cancelled.
Fig. 6