TV One 1T-CL-322-EU Bedienungsanleitung

Firmware versions EU: 2.21 US: 2.11 and above
MNL-1T-CL-322-V1.4
July 2017
1T-CL-322-EU 15-button Wall Plate
Control Keypad
1T-CL-322-US 16-button Wall Plate
Control Keypad
User Guide V1.4


In this guide
Features.......................................................................................1
Requirements .............................................................................1
In the box ....................................................................................2
Safety precautions .....................................................................3
Front panel..................................................................................4
Rear panel ...................................................................................4
Example of hardware configuration........................................5
External controls ........................................................................5
The 1T-CL-SW software .....................................................5
The web interface...............................................................5
Network settings ................................................................7
External control with Telnet and UDP.............................8
Configuring the Control Panel................................................11
Setting the date and time................................................11
Macros and extension macros .......................................11
Button modes...................................................................12
Default macros .................................................................12
Creating and editing macros ..........................................13
Labelling buttons..............................................................16
Creating and editing command strings.................................17
Creating a command string ............................................17
Editing a command string...............................................17
Commands for controlling Control Panels ...................18
Commands for controlling relays ..................................20
Controlling other devices................................................20

Commands for controlling tvONE™ devices ................21
Scheduling macros...................................................................23
Creating and editing repeating schedules....................23
Creating and editing one-off events..............................24
Adding and editing devices.....................................................24
What are devices? ............................................................24
Adding a device ................................................................25
Editing a device ................................................................25
Changing your username and password..............................26
Setting a timeout time.............................................................26
Saving and restoring your settings........................................27
Factory default settings...........................................................27
Restoring the factory default settings...........................27
Rebooting the Control Panel ..................................................28
Firmware ...................................................................................28
Finding your firmware version.......................................28
Updating firmware...........................................................29
Specifications............................................................................31
Regulatory compliance............................................................31
Contact us .................................................................................32

MNL-1T-CL-322 V1.4 1
Thanks for buying this 1T-CL-322 Control Panel from tvONE™.
The Control Panel allows you to control a range of devices through
an Ethernet connection and relay outputs. It has red and blue LED
backlights that you can use to create color themes and show
activation of commands.
The Control Panel comes in two models. The EU model has 15
buttons and the US model has 16 buttons. Each model has a full set
of primary and extended macro commands, and can store up to 128
commands.
Features
15 or 16 macro buttons
15 or 16 virtual buttons accessed
through web interface
Up to 16 commands per macro
Store up to 128 commands
Control devices with relays that
support DC 0-24 V / 8 A
Store settings for all your devices
Scheduling control system and
settings
Control with the keypad, Telnet,
UDP, and web interface
Supports Power over Ethernet
Requirements
Ethernet connection from switch or router
Optional: Power over Ethernet

2 tvONE
In the box
EU model
US model
Wall-mounted keypad
USB Type A to Mini USB
OTG adaptor with cable
3.5 mm Phoenix
connectors
5 V / 2.6 A DC power
adaptor, with regional
connectors
Pre-printed labels for
buttons, with regional
differences
User guide
1T-CL-322
1T-CL-

MNL-1T-CL-322 V1.4 3
Safety precautions
Read all instructions before attempting to unpack, install or operate this
equipment, and before connecting the power supply.
Risk of injury from fire or electric shock
•Follow basic safety precautions.
•Do not expose this product to rain or moisture.
•Do not install this product near water.
•Do not spill liquid onto or into this product.
Risk of damage to equipment
•Do not push an object of any kind into this product
through any openings or empty slots.
•Use only the supplied AC power cord. Do not use the
power cord if it is damaged.
•Do not block any vents or openings in the unit housing
that provide ventilation. Allow sufficient space for air to
circulate around the unit.

4 tvONE
Front panel
Buttons
Each button can support up to 16 commands and
has two LEDs, one red and one blue, adjustable
from 0% to 100%.
Rear panel
Ethernet
Connect to an active Ethernet connection, or
direct to a PC or Laptop. This connection supports
48 V Power over Ethernet (PoE).
Power/DC 5V
If you don’t use PoE, connect the 5 V power
adaptor.
Relay/Relay out
Connect to a device that requires 0-24 V / 8 A DC
power through a relay or contact closure switch.
1T-CL-322
1T-CL-322
EU version US version
EU version US version

MNL-1T-CL-322 V1.4 5
Example of hardware configuration
In this example the Control Panel controls multiple devices with a single
Ethernet port. Power over Ethernet allows for greater flexibility in system
design and installation as a local power supply is not required. In addition
to the Ethernet port, two relay outputs are used to trigger mechanical
devices such as motorized curtains and an electric screen.
External controls
The 1T-CL-SW software
You can connect to the Control Panel, find out its IP address and firmware
version, and open the web interface from the 1T-CL-SW software.
Download the software for both the EU and US models from the
Downloads tab at www.tvONE™.com/wall-plate-control-panel.
The web interface
You can control and configure the Control Panel from any modern
browser with the web interface.
The default port for the web interface is 80.
C2-2855 scaler
AV source
Ethernet Switch
Audio amp
1T-CL-322
ON ONVC
PC1
PC2 OFF
BR
OFF
Mute
50%
75%
Lighting Controller Curtain Controller
Ethernet Relays
48v PoE

6 tvONE
Finding out the IP address of your Control Panel
The Control Panel automatically uses DHCP to get an IP address when it is
connected to a valid network. You can find out the IP address of your
Control Panel on the 1T-CL-SW software.
1. Connect the Control Panel and a computer to the same Ethernet
network.
2. In the 1T-CL-SW software, select Find Devices on Network.
3. Select your Control Panel from the list.
4. On the InfoFrom window, check the network settings of the
Control Panel.
5. To connect to the Control Panel, the IP address of your computer
and Control Panel must belong to the same range. If they are not,
you can edit the network settings of the Control Panel.
Contact the network administrator for information about the network.
If the network doesn’t support DHCP, use the static factory default IP
address 192.168.1.50 and the default subnet mask 255.255.255.0.
Opening the web interface
1. To open the web interface, open any browser and enter the IP
address for the Control Panel, or select the Web GUI link on the
InfoFrom window.
2. Log in with username: admin and password: adminpw.
Andere Handbücher für 1T-CL-322-EU
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere TV One Bedienfeld Handbücher