INSTALLER’S MANUAL
R16 Radio Control Panel
INSTALLATION AND PROGRAMMING MANUAL
Revision 1
8QLWHFK

Introduction......................................................................................................................4
Compatibility ....................................................................................................................5
INSTALLATION ................................................................................................................ 6
Power up procedure ........................................................................................................6
Connection Diagram........................................................................................................ 8
Inputs / Outputs ...............................................................................................................9
R16 Keypad.................................................................................................................... 10
Audible & Visual feedback....................................................................................... 10, 11
User Tests.......................................................................................................................11
OPERATION ................................................................................................................... 12
Operation Summary....................................................................................................... 13
Alarm Type Descriptions ................................................................................................ 14
System Alarm Descriptions............................................................................................ 15
Quick Start Panel Programming....................................................................................16
Quick Start RADIO Programming .................................................................................. 17
PROGRAMMING ............................................................................................................ 19
How to enter Program Mode ......................................................................................... 19
PANEL PROGRAMMING OPTIONS..........................................................................20-35
DIALLER PROGRAMMING OPTIONS.......................................................................37-43
FACTORY DEFAULT OPTIONS...................................................................................... 45
CENTRAL STATION MONITORING ...............................................................................48
Contact ID reporting codes ........................................................................................... 48
Radio Accessories ................................................................................................... 50, 51
PROGRAM OPTIONS SUMMARY.............................................................................52-55
CONTENTS

4
INTRODUCTION
The 8QLWHFK R16 is a unique fully self-contained radio control panel.
The panel has a built-in keypad for programming and user operation, a built-in piezo siren, built-in
LCD display, built-in radio receiver, built-in battery backup and built-in dialler.
The R16 supports up to 16 8QLWHFK Radio PIRs and up to 14 8QLWHFK Radio Keys. All 8QLWHFK supervised
and encrypted radio devices are supported. There is even a Doorbell feature with selectable tunes
when used with the 8QLWHFK Radio Doorbell transmitter. (If the radio doorbell is available in the local
frequency).
In addition to radio devices, the R16 has 1 hardwired zone and 1 hardwired tamper input for
connection of a wired detection device and external siren cover tamper switch.
The built-in piezo siren provides high volume audible warning. The R16 also has Siren, Piezo and
Strobe outputs for additional hardwired noisemakers.
The R16 has a number of sophisticated power saving features designed to provide at least 48 hours
service running on the backup battery alone. (This includes one full alarm condition with sirens,
strobe and dialler).
The built-in dialler uses Contact ID format for central station monitoring as well as audible monitoring
to any telephone. The user can also dial into the system for remote arming and disarming over the
telephone line.
SPECIFICATIONS
Radio zones ......................... 16
Hardwired zones.................. 1 (operates in series with zone 16)
Hardwired tamper zones ..... 1
Radio compatibility .............. 8QLWHFKY supervised & encrypted radio devices
Dialler format........................ Contact ID & Audible Pulse
On board Keypad................. Backlit, programming & user functions
LCD display.......................... High contrast icon display
Plug pack ............................. 220-240V AC 50-60Hz, output 17V AC @300mA
Quiescent current draw ....... 10 mA (in power save mode if mains is off)
Built-in backup battery......... 12 volt 0.8 Amp/hour, sealed lead acid
Dynamic Battery Test ........... Every Hour and on arming/disarming
Fuses.................................... 2A resettable / sirens2A resettable / Reset output,
built-in piezo and strobe
Siren output.......................... 1 x 8 Ohm horn speaker max.
On board piezo siren ........... 110 dB
Reset output......................... 12V DC 300mA max.
Strobe output ....................... 12V DC, 1 strobe light max.
Dimensions .......................... 210(w) x 145(h) x 40(d) mm

5
COMPATIBILITY
The 8QLWHFK R16 supports all 8QLWHFK radio devices as shown below. All late model8QLWHFK transmitters
send encrypted transmissions to prevent eavesdropping and substitution. 8QLWHFK fixed transmitters
can send a regular supervision signal which the R16 monitors to ensure system security.
* Available in selected areas.

R16 - Installation and Programming Manual
6
INSTALLATION
INSTALLATION PROCEDURE
The location of the main panel housing should be in an area
that is within the protected area of the premises. A linen closet
or cupboard are good examples as these are generally located
in the centre of the premises.
1. Remove the front housing by first removing the bottom
locking screw, (screw is not fitted for shipping), then
unclip the bottom of the front housing and lift upwards.
2. Disconnect the 12 way wire loom from the main board on
the front housing.
3. Unclip and remove the terminal board from the back
housing and remove the battery. (The battery lead
connects to the main board on the front housing. It is not
plugged in for shipping). The terminal board and battery
must be removed to reveal all four mounting holes in the
back housing.
3. Mount the back housing to the wall using the 4 slotted
mounting holes.
4. Replace the Terminal Board in the back housing and
reconnect the 12 way wire loom to the main board.
5. Connect the plug pack wiring to the Terminal Board,
(making sure that mains power is not turned on at this
stage). Connect siren wires and external tamper inputs as
required.
6. Replace the battery.
POWER UP PROCEDURE
The power up procedure assumes that installation of the R16
is completed and the plug pack is wired.
7. Connect the battery lead to the BATTERY socket on the
main board.
8. Turn on the plug pack.
Note 1: When power is applied, the R16 will enter Disarmed
mode, unless it was in Armed or Monitor mode when previously
running, in which case it will resume in the previous mode -
UNLESS the box tamper or external tamper inputs are unsealed.
(See note 2).
Note 2: To enter Installer Program Mode on initial power up,
apply power with the internal tamper open, (lid open), or the
external tamper open.
Note 3: The BATTERY icon will flash if the initial battery voltage is
low and will turn off when the battery has reached full charge.
PACKING LIST
1 R16 Control panel
1 Plug pack 17VAC
300mA
1 Battery 12V 0.8Ah
1 Telephone lead
1 User manual
1 Installer manual
1 Zone list label
3 2K2 resistors
Removing the
Front housing

R16 - Installation and Programming Manual 7
Cable entry via cavity wall
Cable entry via conduit
Lid Assembly
CABLE ENTRY
Cable for the plug pack and optional
accessories can be drawn through
a cavity wall into the rear of the R16
or on the surface via conduit into
the top of the R16 rear housing as
shown below.

R16 - Installation and Programming Manual
8
CONNECTION DIAGRAM
"#$ "
% &
'
-.
'
( )* '
+
EARTH AC
TAM P
STR+
PIEZ+
0V ZONE
+
PIEZ
STR
SIREN
+$
",
EARTH AC
TAMP
STR+
PIEZ+
0V ZONE
+
PIEZ
STR
SIREN
17V AC
Earth
External Horn Speaker Max. Qty 1.
Strobe Light Max. Qty 1.
Hardwired Zone Input, 2K2 EOL resistor
0V ground for accessories. 100mA max.
External Screamer Max. Qty 1.
Plug Pack 17VAC 300mA (Supplied).
2K2
N.O. Tamper Switch
N.O.
N.C.
!
+12V for accessories. 100mA max.

R16 - Installation and Programming Manual 9
INPUTS / OUTPUTS
INPUTS
ZONE
Zone input for optional hardwired detection devices. Operates in series with any radio devices
on zone 16. The input must be terminated with a 2K2 (2200 ohm) end of line (EOL) resistor
even if unused.
This input is normally used for connecting an optional hardwired reed switch or a 12V
powered smoke detector.
TAMP
24hr input for connection of external tamper switches. This input operates in series with the
internal tamper switch.
The input must be terminated with a 2K2 (2200 ohm) end of line (EOL) resistor even if
unused.
AC / EARTH
AC power input and earth connection. Use the supplied 17V AC 300mA plug pack.
OUTPUTS
SIREN
Timed siren output for connection of maximum one (1) 8 Ohm horn speaker.
STR
Output for connection of 1 x strobe light. As a power saving feature, the strobe output times
out after 11 hours. If mains power is off, the output will time out after 1 hour.
PIEZ
Timed output for connection of maximum 1 x 12V screamer.
ONBOARD SIREN (BUILT-IN)
The onboard piezo siren is an integral part of the R16 electronics. It is used for keypad
beeps, doorbell chime, arm/disarm chirps and internal siren on alarm. The internal Siren can
be disabled by program option P60E 8E. When the Internal Siren function is disabled, the
onboard siren still outputs keypad beeps and other audible features.
12V SUPPLY FOR ACCESSORIES
If 12V power is required for a device such as a hardwired smoke detector, use Zone Input
0V (negative) and SIREN+ (positive). No more than 100mA should be drawn from these
terminals.

R16 - Installation and Programming Manual
10
R16 KEYPAD
AUDIBLE & VISUAL FEEDBACK
The R16 onboard keypad provides the facility for user level and installer level programming and all
user operation and emergency functions. The keys are soft-touch silicon rubber and are backlit for
high visibility. Any keypress will turn on the backlighting for 4 minutes.
2
5
8
0
1
4
7
P
3
6
9
E
PROGRAMFUNCTION BUTTONSONBOARD SIREN
/ BEEPER
FIRE
MEDICAL
PANIC
BACKLIT
LCD DISPLAY
ENTER
OUTPUT TYPEOUTPUT DESCRIPTION
Keypad Acknowledge key press
Keypad Valid entry, end of Exit Time
Keypad Invalid entry
Low battery / AC Fail / Medical Alarm
Alarm, Entry Delay, etc
Arm
Disarm
The Doorbell has been pressed.
Alarm condition
Panel Armed or Disarmed
Alarm condition
Keypad beeper
Onboard Siren
External Siren output
Onboard Siren
Piezo output
External Siren output
Strobe output
Onboard Siren
External Siren output
Onboard Siren
SHORT BEEP
3 BEEPS (RAPID)
LONG BEEP
8 BEEPS (RAPID)
CONTINUOUS BEEPS
1 CHIRP*
3 CHIRPS*
DOORBELL TONES**
SIREN CONTINUOUS
STROBE BURST
STROBE CONTINUOUS
SIREN BURST,
(Low Volume)
Zone Auto Exclude warning
* Arm/disarm chirps must be enabled. P64E 4E.
** If the optional Radio Doorbell is available in your region.

R16 - Installation and Programming Manual 11
LCD DISPLAY
KEYPAD BEEPER NOTE:
If the onboard siren is
disabled, (P60E 8E =
on), keypad beeps are
also disabled during
an alarm condition.
Keypad beeps will be
reactivated on the next
disarm.
USER TESTS
Test functions can be invoked by pressing and holding the specified
keypad button, as follows. The Panel must be in Disarmed mode.
BUTTON TEST PERFORMED
9Dialler Listen-in. Press and hold keypad button ‘9’
for 3 seconds to enable the Dialler Listen-in function.
All dialler tones are output through the onboard siren.
This allows the installer to hear dial tone, dialling tones,
central station handshake and kiss-off tones. This test
automatically turns off after 2 minutes.
EDisplay Test. Press and hold keypad button ‘E’ for 1.5
seconds. Turns on all LCD icons while the button is
pressed.
Zone is sealed
Not ready to arm - unsealed
zones or system faults
Disarmed
Disarmed
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Zone is unsealed
Ready to Arm
Armed
Monitor Mode
Memory Mode selected
Receiving radio signal
Dialler is on line
Indicates that a Radio Key or
other radio device has a low battery
*
Phone line fault or
failure to communicate
User Program Mode
Zone alarm
Mains Power is off
The panel’s backup
battery is low
New alarms in memory
Zones are excluded
Tamper alarm
Installer Program Mode
ZONES 1-8
OFF ON FLASHING
DISPLAY
KEYPAD DISPLAY IN OPERATING MODE
* The flashing RADIO fault icon could be indicating that the radio key/device has either low battery or
supervision failure or other radio related problems. The numeric display 1–15 will show which device is
sending the signal.
See page 19: The table KEYPAD DISPLAY IN MEMORY REVIEW MODE provides further detail.