UTC 1070140-EN Bedienungsanleitung

UltraView IP Box
Day/Night Range Camera
User Manual
P/N 1070140-EN • REV 1.0 • ISS 05NOV10

Copyright © 2010 UTC Fire & Security. All rights reserved.
Trademarks and
patents The UltraView name and logo are trademarks of UTC Fire &
Security.
GE and the GE monogram are trademarks of the General Electric
Company and are under license to UTC Fire & Security, 9 Farm
Springs Road, Farmington, CT 06034-4065, USA.
Other trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the
respective products.
Manufacture
r
UTC Fire & Security Americas Corporation, Inc.
2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands.
Certification N4131
FCC compliance Class A: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
European Union
directives 2004/108/EC (EMC directive): Hereby, UTC Fire & Security declares
that this device is in compliance with the essential requirements and
other relevant provisions of Directive 2004/108/EC.
2002/96/EC (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see:
www.recyclethis.info.
Contact information For contact information see our Web site:
www.utcfireandsecurity.com

Content
Introduction 3
Product description 3
Features 3
Installation 4
Installation environment 4
Package contents 4
Cable requirements 4
Setting up the camera 5
Camera description 6
Lenses 6
Mounting the camera 6
Connections 7
Alarm connection 7
Connecting analog cables 8
Setting the camera DIP switches 8
Description of the DIP switch settings 9
System configuration 11
Software requirements 11
Windows Vista and 7 users 11
Accessing the camera over the internet 12
Overview of monitoring and configuring the system 12
Live viewing 13
Monitoring the system 13
Configuring the camera and network 15
Specifications 18
Warranty and contact information 19
Warranty information 19
Contacting support 19
UltraView IP Box Day/Night Range Camera User Manual i

ii UltraView IP Box Day/Night Range Camera User Manual

Introduction
Product description
The UltraView IP box day/night range camera uses a digital signal processor
(DSP) to process video signals. The video camera includes a microcontroller to
provide high-quality images with high-color reproduction and sharp pictures.
Product codes:
• UVC-IP-EVRDN-HR
• UVC-IP-EVRDN-HR-P
Features
Camera features include:
• H.264-SVC video compression with multistream capability.
• Super HAD (hole accumulated diode) technology with 470,000 PAL (410,000
pixels NTSC).
• Use of LSI (large scale integration) digital processors to produce 4CIF
resolution images (540 lines of horizontal resolution analog).
• High-resolution picture production using digital signal processors for
horizontal and vertical aperture enhancement.
• Smart digital automatic BLC (back light control).
• Advanced autoexposure system to optimize the amount of light to the imager.
• Internal or line lock external synchronization.
• Long life and high reliability.
• DIP switch control of camera settings.
• Signal-to-noise ratio better than 48 dB.
• Power over Ethernet (PoE) or Isolated switching power 12 VDC or 24 VAC.
UltraView IP Box Day/Night Range Camera User Manual 3

Installation
Installation environment
When installing your product, consider these factors:
• Electrical: Install electrical wiring carefully. It should be done by qualified
service personnel. Always use a proper PoE switch or a 12 VDC or 24 VAC
UL listed Class 2 or CE certified power supply to power the camera. Do not
overload the power cord or adapter.
• Ventilation: Ensure that the location planned for the installation of the
camera is well ventilated.
• Temperature: Do not operate the camera beyond the specified temperature,
humidity or power source ratings. The operating temperature of the camera is
between -30 to +50°C (-22 to +122°F). Humidity is below 90%.
• Moisture: Do not expose the camera to rain or moisture, or try to operate it in
wet areas. Turn the power off immediately if the camera is wet and ask a
qualified service person for servicing. Moisture can damage the camera and
also create the danger of electric shock.
• Servicing: Do not attempt to service this camera yourself. Any attempt to
dismantle or remove the covers from this product will invalidate the warranty
and may also result in serious injury. Refer all servicing to qualified service
personnel.
WARNING: To reduce the risk of fire or electronic shock, do not expose the
camera to rain or moisture and do not remove the cover or back.
Package contents
The camera is shipped with the following items:
• The camera assembly
• 1 channel passive video transceiver
• AC power wiring harness
• 150 mm DC jack to terminal adapter
Cable requirements
For proper operation, adhere to the following cable and power requirements for
the cameras. Category 5 cabling or better is recommended. All network cabling
must be installed according to applicable codes and regulations.
4 UltraView IP Box Day/Night Range Camera User Manual

Table 1 below lists the requirements for the cables that connect to the camera.
Table 1: Recommended cable requirements
Cable type Requirements
Video 75 ohm RS-59 coaxial cable with BNC ends
Power 24 VAC cable
Setting up the camera
Note: If the light source where the camera is installed experiences rapid, wide-
variations in lighting, the camera may not operate as intended.
To quickly put the camera into operation:
1. Connect the lens to the camera.
2. Prepare the mounting surface and mount the camera to the wall/ceiling using
the appropriate fasteners.
3. Connect the cables to the camera.
4. Connect a CCTV monitor to the system to program the camera.
5. Set the camera’s DIP switches, which are located on the rear of the camera,
to suit the camera’s location. See “Setting the camera DIP switches” on page
8.
6. Set up the camera’s network and streaming parameters so that the camera
can be controlled over the network. See “Accessing the camera over the
internet” on page 12.
UltraView IP Box Day/Night Range Camera User Manual 5

Camera description
Figure 1: Side view of box camera
1. Auto iris lens connector
Video-type auto iris lens connection:
A. Video (white); B. Power; C. NC;
D. GND (black)
DC-type auto iris lens connection:
A. Driving coil (+);B. Damping coil (+);
C. Damping coil (-); D. Driving coil (-)
2. Camera
3. Backfocus adjustment
4. Lens (auto iris lens shown. Manual lens has
no cable.) Not included
5. Backfocus lock screw
6. Auto iris lens cable. Not included
Lenses
Attach a manual lens using an auto electronic shutter (AES) lens or attach an
auto iris (AI) lens.
Mounting the camera
To mount the camera, attach the camera to the prepared mounting surface using
the appropriate mount.
6 UltraView IP Box Day/Night Range Camera User Manual

Connections
Figure 2: Rear panel of camera
1. Power LED.
2. Reset button.
Press to reset camera to factory default
settings.
3. Ethernet RJ45 port.
Connect to network devices.
4. DIP switches.
Configure camera settings.
5. Alarm input and output.
Connect to be able to trigger an alarm at
the network device.
6. Power supply.
Connect 12 VDC or 24 VDC power supply.
7. Video output.
Connect to a CCTV monitor
Alarm connection
Figure 3: DC alarm input and output wiring
1. OUT 2. GND 3. IN 4. GND
Table 2: Description of alarm connections
Alarm input
Type TTL. Compliant with 48 V input voltage.
Connector type Screw terminal
UltraView IP Box Day/Night Range Camera User Manual 7

Alarm output
Type Open collector. Compliant with 48 V external power.
Connector type Screw terminal
Connecting analog cables
Connect a standard CCTV monitor to the system to adjust the quality of the video
image using the DIP switches. The DIP switches can also be adjusted when
connected to the IP system.
To connect the cables:
1. Connect a coaxial cable from the camera’s BNC connector to a CCTV
monitor or video recording device.
2. Connect a PoE switch, a 12 VDC or 24 VAC power supply to the power input.
Do not connect both the PoE connection and DC or AC connection at the
same time. The label on the camera gives the following information:
Red cable. Power in.
Black cable. Power in.
White cable. Video out.
Black cable. Video ground.
Note: For 24 VAC or 12 VDC, Black or Red may be used for ground.
Setting the camera DIP switches
You can set up six camera functions using the DIP switch bank on the rear of the
camera. Figure 4 below shows the DIP switch layout. See “Description of the DIP
switch settings” on page 9for information on these functions.
Figure 4: DIP switch layout (located on rear of camera)
OFF
ON (Default)
8 UltraView IP Box Day/Night Range Camera User Manual
Dieses Handbuch passt für folgende Modelle
6
Inhaltsverzeichnis