V44 Duo Installation & User manual 3
ENG
English
Technical specications and availability subject to change without notice.
© Copyright Vanderbilt International (IRL) Ltd.
We reserve all rights in this document and in the subject thereof. By acceptance
of the document the recipient acknowledges these rights and undertakes not to
publish the document nor the subject thereof in full or in part, nor to make them
available to any third party without our prior express written authorization, nor to
use it for any purpose other than for which it was delivered to him.

4 V44 Duo Installation & User manual
ENG
Contents
What is V44 Duo? ....................................... 5
Duress or alert ............................................................................ 6
Zero opening............................................................................... 6
Unlock the door permanently.................................................... 6
Door bell ...................................................................................... 6
Power supply .............................................................................. 6
The keypad.................................................. 7
Wiring .......................................................... 8
Programming ............................................ 10
Buzzer and LEDs ...................................................................... 10
Choose password .....................................................................11
Change password......................................................................11
Programming commands ........................ 11
Program codes.......................................................................... 12
Erase codes............................................................................... 13
Change codes ........................................................................... 14
Set opening time....................................................................... 15
Background lighting on/off...................................................... 15
Buzzer on/off............................................................................. 16
Toggle function on/off.............................................................. 16
Duress or Alert.......................................................................... 17
Door monitoring on/off............................................................. 18
Set door held warning time...................................................... 19
Delay on/off ............................................................................... 20
Erase the memory..................................................................... 20
Using V44 Duo .......................................... 21
Entrance .................................................................................... 21
Unlock the door permanently.................................................. 21
Enter duress code .................................................................... 22
Technical data........................................... 23

V44 Duo Installation & User manual 5
ENG
What is V44 Duo?
V44 Duo is a compact code lock with two relay outputs.
This makes V44 Duo capable of controlling two doors – or
one door and an optional function, e.g. a light switch. Either
a four- or a six-digit code can be used to open connected
doors. All programming is done from the keypad.
Open two doors using one code
The advantage of using two relay outputs is that two func-
tions can be activated at the same time, using only one
code. For example, the code can open the lock and turn on
a light switch at the same time.
Another setup is to connect the code lock to two doors.
One code is programmed to operate both doors, while the
other only opens one of the doors.
If the code is programmed to open both doors, you can set
V44 Duo so that the other door does not open until the rst
door has been opened and closed (see the Delay section).
For each code, choose whether to activate both relay
outputs, only one or only the other.
Disable the codes whenever needed
V44 Duo offers the possibility to disable codes at certain
times. For example, the cleaning staff’s access to the build-
ing can be limited to certain hours, while tenants/staff can
have access to the door 24 hours a day.
By connecting two time clocks to V44 Duo, three different
time zones can be used to control the codes: one controlled
by time clock 1, one controlled by time clock 2 and one that
is valid 24 hours a day, i.e. no time control.

6 V44 Duo Installation & User manual
ENG
Duress or alert
V44 Duo is equipped with an output that can be activated
for one of the following reasons:
• A user enters a duress code
OR
• The door held warning time expires or the door is
forced open
Choose which alternative to use. Then connect e.g. a bur-
glar alarm or similar to the output.
Zero opening
To make entrance easier, e.g. during ofce hours, connect
an external contact. Then use the contact to activate or
deactivate zero opening, i.e. opening the door by pressing
the zero button on the keypad. Note that this is only applies
to relay output 1.
Unlock the door permanently
If the Toggle function is activated, the code can be used to
unlock the door. The door remains open until a valid code is
entered once again (see the Toggle on/off section).
Door bell
If needed, a door bell can be connected to V44 Duo. To ring
the bell, the visitor presses the button labelled with a bell on
the code lock’s keypad.
Power supply
Ensure that the power supply is stable and within the rated
voltage of the unit. Use an uninterrupted power supply
(UPS) to ensure a continuous function of the unit in the
event of power dips on the mains supply.

V44 Duo Installation & User manual 7
ENG
The keypad
1 2 3
65
98
4
7
B0
A
Red LED
For optional
use, e.g. to
indicate alarm
on.
Yellow LED
Indicates key-
presses.
Green LED.
Lit when the
door is un-
locked.
= A.
Acts as a door bell
button and starts the
sequence telling the
V44 Duo what to you
want to program. E.g.
A21 to program codes.
B.
Press B and enter
the 6-digit password
to programme the
V44 Duo. Press B
to leave the pro-
gramming mode.

8 V44 Duo Installation & User manual
ENG
Wiring
12-24V
1
2
3
4
5
6
SW1
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
LED
TAMPER
0V
1
2
”0”
LOCK 1
0V
EXIT 1
CONTACT 1
LOCK 2
0V
EXIT 2
CONTACT 2
1
2
3
4
5
6
7
8
9
11
10
10
8
9

V44 Duo Installation & User manual 9
ENG
1
Power in, terminal nos 1(+) and 2. 12-24 V. **)
2
Input for extra LED (red), terminal nos 3 and 4. 10-35
V DC. **)
3
Tamper switch, terminal nos 5 and 6. Closed when
the housing is closed. **)
4
Code disabling from external time clock. *)
Input 1: Close terminal nos 8 and 7.
Input 2: Close terminal nos 9 and 7.
5
Output for alert or duress. Use E7 relay. Connect
between terminal nos 10 and 1(+). **)
6
Contact for zero (0) opening. Close terminal nos 11
and 7. *)
7
Output for Door bell (buzzer). Use E7 relay. Connect
between terminal nos 12 and 1(+). *)
8
Input for door contacts. The contact is closed when
the door is closed. Terminal nos 13 and 15 (19 and
21 respectively). *)
9
Exit button. The door opens on closing terminal nos
14 and 15 (20 and 21 respectively). *)
10
Electric locking device. Dashed line refers to locks
with fail-safe function. **)
11
SW1 push button. Used when choosing password
and erasing memory.
*) Cable < 3 m
**) Cable < 30 m

10 V44 Duo Installation & User manual
ENG
Programming
Before you start programming V44 Duo, make a note of the
codes to be used, to what timing group they should belong
and which relay output they should control. At the back of
this manual you will nd a chart designed for this purpose.
Look at the chart as you program V44 according to the
instructions below.
Buzzer and LEDs
During programming you will be guided by the buzzer and
the LEDs.
In programming mode before a function is chosen:
Green and yellow LED ashes.
During programming: Yellow LED goes out. Green LED
is lit.
Correct instruction: Conrmed by a rising signal consisting
of two quick beeps.
Faulty instruction: Conrmed by a falling signal consisting
of two quick beeps.
NOTE! During programming mode, if a button is not
pressed within 20 seconds, the code lock goes back
to normal operation.