Framing can be constructed before or after the replace
is set in place, however, most installers build the frame
before setting the replace.
Frame the replace opening with x 4 lumber or heavier
materials. Refer to framing dimensions shown in Figure
1.
Framing should be positioned to accommodate
wall covering and replace facing material.
This replace is wired for the optional FK6STRAT fan
kit. The fan requires 10VAC, 60 Hz power which may
be connected to the right side of the replace using the
romex pigtail provided with the unit. This power must
be completed the replace is secured and nish
material applied. The romex pigtail should be ocnnected
to house power inside a junction box which includes wall
switch or rheostat.
1. Attach the white wire from house power to the white
wire of the romex pigtail and secure with a wire nut.
. Attach the black wire from the house power to the black
wire of the romex pigtail and secure with a wire nut.
3. Attach the ground wire from house power to the ground
wire of the romex pigtail and secure with a wire nut. (Fig.
9)
The wire nuts must be tight.
Check local building codes to determine if a junction
box is required at the romex pigtail/house wire connection.
Also read junction box and speed control (SCVS) instal-
lation instructions.
Since you have already planned the chimney run, you
should know exactly how the installation is to be ac-
complished - the amount of pipe required, the number of
elbows, if any, and type of termination to be used.
Report to your dealer any parts damaged in
shipment, specically check the end connection of chimney
sections and elbows.
Fireplaces may use Vermont Castings Group Model
SK8, or Model S (three wall) chimney systems. The Strat-
ton Series Fireplace will accept the SK8 chimney system
as shipped; but a TWABR adapter collar is required when
using the Model S (triple wall) chimney system. The instal-
lation procedure described in this manual applies to
the SK8 system. Either chimney system may be used, but
the systems be mixed. The replace must be
modied to install the TWABR adapter. (Fig. 10)
To mark the centerline of the ue, put the replace in nal
position and measure out from the wall: 9Z\x" (41 mm).
Mark a spot on the ceiling directly above the replace.
Draw a line parallel to the back wall through this mark.
(Fig. 10)
Using a plumb bob positioned directly over center point
of replace ue collar, mark the ceiling to establish the
chimney center point. (Fig. 10)
In order to clear an obstruction, it may be necessary to
offset the chimney from vertical. This is accomplished by
using the elbows. Use the 30° Offset Elbow table on Page
6 to determine proper offset and parts required.
Each offset requires two () elbows. The second elbow is
equipped with support straps. It is very important to install
the second elbow in each offset as close to the ceiling or
support as possible so the elbow straps can be secured
to framing members and help support the weight of the
chimney.
Determine offset distance of the chimney arrangement
from the centerline of the replace to the centerline of the
chimney where it is to pass through the ceiling.
Locate the center point of the chimney on the ceiling as
though a straight up chimney arrangement is to be used.
Measure your offset dimension from the straight up chim-
ney center point on the ceiling.
FP1062
romex pigtail
8/21/00 djt
Romex Pigtail
(Provided)
Fireplace Electrical
Coverplate
Wire Nuts
(Not pro-
vided)
Ground
Black
White House
Wiring
(10V
60Hz)
FP106
Wiring diagram.