READ AND SAVE THESE INSTRUCTIONS
MODEL VEDV1200
EXTERIOR MOUNTED BLOWER
FOR USE WITH VIKING MODEL VIPR181 AND VIPR181R
48" DOWNDRAFT VENTILATOR ONLY.
WARNING
TOREDUCETHERISKOFFIRE,ELECTRICSHOCK,OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufac-
turer or your distributor.
2. Before servicing or cleaning unit, switch power off at
servicepanelandlock the service disconnecting means
to prevent power from being switched on accidentally.
Whentheservicedisconnectingmeans cannotbelocked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
ProtectionAssociation (NFPA), and the American Soci-
etyforHeating, Refrigeration and Air Conditioning Engi-
neers (ASHRAE), and the local code authorities.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
PLANTHE
INSTALLATION
1. Locate the blower so the
length of the duct run and
numberofelbowsneeded
are kept to a minimum.
2. Where possible, blower
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or
other ductwork that may
berunningthroughthewall.
ALL INSTALLATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
VEDV1200 120 3.0 1200 10" DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
TYPICAL ROOF MOUNTED INSTALLATION TYPICAL WALL MOUNTED INSTALLATION
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
WARNING
10" ROUND
DUCT
TO
DOWNDRAFT
MODEL VEDV1200
EXTERIOR BLOWER
MODEL
VEDV1200
EXTERIOR
BLOWER
10" ROUND DUCT
TO
DOWNDRAFT
Blower Dimensions
22 x30.828 x12.724