1. Operation description
1. Light is on constantly
Checking SIM, find and register in the network
2. Flashes 1 time in 3sec.
3. Flashes 1 time in 5sec.
Set GPRS connects/RING/SMS/USSD
Getting started
1. Before insert a SIM-card set to off PIN-code request. Insert and change
SIM-card when the device is off power supply.
2. The first income call number is saved automatically into the sell num1 (the
sell num1 should be empty).
3. The device processes USSD-commands only in Latin alphabet, in case reply
by numbers, request the operator to change the encoding to the transliteration.
4. The default setup is "heater_type0" - automatically identifies type of
connected heater (digital TTC/TTV or analog).
5. Summer mode – heater_type7 (only interior ventilation control).
6. Setup "bind1" sets interfacing with other controls Webasto (GSM module
activated heater, Timer 1533 deactivated).
7. When using the fixed-type button (setup key0) the heater will not turn off
automatically at time expiration "time1".
8. At "setsms1" the user gets SMS about start and stop Webasto.
9. At "errorsms1" the user gets SMS about errors of Webasto work.
10. Before set up function of control heater temperature (if the value is above
"temp_high" - Webasto stops, if lower "temp_low" – starts), request the status
message, to control the precise definition by the device temperature of the
Webasto heater.
Mobile Web-application (description: http://altox.by/mobile_webasto)
1. To activate GPRS - input the APN of access point SIM-card operator of the
device (see setup apn1, apn2, apn3). To deactivate GPRS - delete APN access
point, by sending SMS command "apn1:".
2. All setup GPRS changes will come into force after one minute.
3. Size of TCP-packs: ping - less 10byte, status - less 100byte.
Incoming call
At "voice0" (voice is off) and incoming call of saved number, the call is
rejected, but Webasto starts (1beep) / stops (2 beeps).
If the number is not saved /not identified, the call is rejected only.
At "voice1" (voice menu is on) possible to input DTMF-commands:
oActivate/deactivate the heater – push 1.
oRequest a balance – push 2.
oRequest a status – push 3.
After one minute the connection automatically discontinued.