Wolf BM-Solar Bedienungsanleitung

3061916_0611 Subjecttomodications 6.6701.615 GB
Installation and
operating instructions
Programming module BM-Solar
Wolf GmbH · Postfach 1380 · D-84048 Mainburg · Tel. +49-8751/74-0 · Fax +49-8751/741600 · Internet: www.wolf-heiztechnik.de

2 3061916_0611
Index
Safety instructions / Standards...............................................3
Standards / Regulations ..........................................................4
Installation
• Applicationrange...........................................................5
• Moduleinstallation.........................................................5
• Asaremotecontrol........................................................5
• Wallmountingbase.......................................................5
• Remotecontrolpowersupply........................................6
Overview
• Standarddisplay............................................................7
• Statusdisplay................................................................7
Display level
• Informationdisplay(Infokey).........................................8
• DisplayvaluesSM1.......................................................9
• DisplayvaluesSM2.......................................................9
• Descriptionofdisplayvalues................................. 10-13
Parameter level
• Accesstotheparameterlevel.....................................14
• SM1parameters..........................................................15
• SM2parameters.................................................... 16-17
System ON / OFF ....................................................................18
Specication ...........................................................................18
Troubleshooting .....................................................................19

3061916_0611 3
Thefollowingsymbolsareusedinconjunctionwiththeseimportant
instructions concerning personal safety as well as operational
reliability.
"Safetyinstructions"areinstructionswithwhichyoumustcomply
exactly,topreventinjuryandmateriallosses.
Dangerthrough'live'electricalcomponents.
NBSwitchOFFtheON/OFFswitchbeforeremovingthe
casing.
NevertouchelectricalcomponentsorcontactswhentheON/OFF
switchisintheONposition.Thisbringsariskofelectrocutionthat
maycauseinjuryordeath.
The main supply terminals are 'live' even when the ON / OFF
switchisintheOFFposition.
This indicates technical instructions that you must observe to
preventmateriallossesandboilermalfunctions.
NB
Safety instructions
The appliance and control unit accessories comply with the
followingregulations:
EC Directives
-2006/95/EC LowVoltageDirective
-2004/108/EC EMCDirective
EN Standards
- EN55014-1 Interferenceemissions
-EN55014-2 Resistancetojamming
-EN60529
Standards / Directives
Safety instructions / Standards

4 3061916_0611
Standards / Regulations
-AccordingtoDINEN50110-1,onlyqualiedelectriciansmay
carryouttheinstallationandcommissioningoftheheatingcontrol
unitandconnectedaccessories.
-Observeall regulationsspecied byyour local powersupply
utilityandallVDEorlocalregulations.
-DIN VDE 0100 regulations regarding the installation of high
voltagesystemsupto1000V
-DINVDE0105-100operationofelectricalsystems
Installation /
Commissioning
Warnings -Never remove, bypass or disable safety and monitoring
equipment.
-Only operate the system in perfect technical condition.
Immediatelyremove/remedyanyfaultsanddamagethatmay
impactonsafety.
- Alwaysensurethatcoldwaterismixedinwithhotwater,when
theDHWtemperatureissetabove60°C(riskofscalding).
Maintenance / Repair -Regularlychecktheperfectfunctionofallelectricalequipment.
-Onlyqualiedpersonnelmayremovefaultsorrepairdamage.
-OnlyreplacefaultycomponentsorequipmentwithoriginalWolf
spareparts.
AnydamageorlossresultingfromtechnicalmodicationstoWolf
controlunitsisexcludedfromourliability.
NB
Observethefollowinginformationregardingthedisposaloffaulty
systemcomponentsorthesystemattheendofitsservicelife:
Dispose of all components in accordance with applicable
regulations,i.e.separatematerialgroupscorrectly.Theaimshould
bethemaximumpossibleamountofbasicmaterialsrecycledand
thelowestpossibleenvironmentalimpact.
Neverthrowelectricalorelectronicscrapintothehouseholdwaste,
butrecycleitappropriately.
Generally, dispose of materials in the most environmentally
responsible manner according environmental, recycling and
disposalstandards.
Disposal and recycling

3061916_0611 5
Installation
TheBM-Solar programming modulecan beintegrated intothe
SMsolarmoduleorcanbeusedasremotecontrolinconjunction
withawallmountingbase.
WhenintegratingtheBM-Solarinthesolarmodule,allsettings
aremadeatthesolarmodule.
The electrical connection must only be carried out by a
qualiedelectrician.
- SwitchOFFthepoweratthesolarmodule
- Removethefaciafromthesolarmodule
- ClicktheBM-Solarprogrammingmoduleintothesolar
moduleasshowninthediagram
- SwitchONthepoweratthesolarmodule
Module installation
Remote control Fittedtoawallmountingbase(partno.2744275),theBM-Solar
programmingunitcanbeusedasaremote control(e.g.inthe
livingroom).
Onlyatwo-wireBUSisrequiredfortheuseasremotecontrol.
Wall mounting base
installation
- Removethewallmountingbasefromitspacking.
- Secure the wall mounting base on a ush-mounting box
(Ø55mm)ordirectlyonthewall.
Wallmountingbase
Fixingholes Fixingholes

6 3061916_0611
Installation
Electrical connection
Remote control
Theelectricalconnectionmustonlybecarriedoutbyaqualied
electrician.
Neverroutesensorleadsalongsidemainspowercables.
- SwitchOFFthepoweratthesolarmodule
- Wire the wall mounting base with a two-core cable (minimum
cross-section0.5mm²)inaccordancewiththediagramshown
- ClicktheBM-Solarprogrammingmoduleintothewallmounting
baseasshowninthediagram
- SwitchONthepoweratthesolarmodule
green
eBus
Greenplugof
thesolarmodule
Terminalstrip
Wallmountingbase

3061916_0611 7
Overview
Rotary selector with
pushbutton function
ON / OFF
pushbutton
Status display
Solar circuit pump
Info
pushbutton
▪ Inthetoplineofthestandarddisplay,thecurrentsolar cylinder
temperature is shown; the bottom line shows the current
collector temperature.
▪ Insystemswithtwocylinders,thesolarcylindertemperatureof
cylinder1isshown.
▪ Insystemswithtwocollectorarrays,thecollectortemperature
ofcollectorarray1isshown.
▪ The BUS symbol indicates that a BUS connection exists
betweentheprogrammingmoduleandtheSMsolarmodule.
TheBUS connection is faultyifthissymbolisnotdisplayed.
Thiswouldpreventthesolarmodulefrombeingoperated.
An arrow on the status display signals which output of the
connectedsolarmoduleiscurrentlyactive.
Standard display Solarcylindertemperature,cylinder1
BUSsymbol
Collectortemperature,collectorarray1
Statusdisplay,outputA4
Statusdisplay,solarcircuitpump1and
outputsA1-A3
Display
In conjunction with
Status display SM1 solar module SM2 solar module
Solarcircuitpump Solarcircuitpump1
A1 -OutputA1*
A2 -OutputA2*
A3 -OutputA3*
-** -OutputA4*
Status display
* Outputassignmentsubjecttoconguration.
** AnactiveoutputA4issignalledbyanarrowpointingdownwards.

8 3061916_0611
Display level
Example:displayvalueA01
Inadditiontothevaluesshownonthestandarddisplay,further
values for the solar thermal system can be scanned at the
BM-Solar.
PressingtheInfo keyleadstothedisplaylevel.Thedisplayvalue
A01(solarcylindertemperature,cylinder1)isshown.
Information display
PressingtheInfokeyagainorturningtherotaryselectorclockwise
enablesalladditionaldisplayvaluestobescannedinsequence.
If the nal display value is reached and the selector further is
turnedfurther,thesystemexitsthedisplaylevelandreturnsto
thestandarddisplay.Thestandarddisplayreturnsautomatically
ifnofurtheractivityisdetectedwithinthenextminute.
Press
Rotary selector with
pushbutton function
Info key

3061916_0611 9
Display Designation
A : 0 1 ActualDHWtemperature,solarcylinder(°C)
A : 0 2 Max.DHWtemperature,solarcylinder(°C)
A : 0 3 Collectortemperature(°C)
A : 0 4 Maximumcollectortemperature(°C)
A : 0 5 Returntemperature(°C)
A : 0 6 Solarcircuitowrate(l/min)
A : 1 0 Hoursrun,solarcircuitpump(h)
A : 1 2 Currentoutput(kW)
A : 1 3 Currentdayyield(kWh)
A : 1 4 Totalyield(Wh)
A : 1 5 Totalyield(kWh)
A : 1 6 Totalyield(MWh)
A : 1 7 Solarheatingstatus
(0=unsuccessful,1=successful)
Display values used with
SM1 solar module
Subject to the solar module used, different display values are available.
Display Designation
A : 0 1 ActualDHWtemperatureinsolarcylinder1(°C)
A : 0 2 Max.DHWtemperature,solarcylinder1(°C)
A : 0 3 Collectortemperature,collectorarray1(°C)
A : 0 4 Maximumcollectortemperature,collectorarray1(°C)
A : 0 5 InputE1*
A : 0 6 InputE2:solarcircuitowrate(l/min)
A : 0 7 InputE3*
A : 0 8
MaximumDHWtemperature,solarcylinder2(°C)
A : 0 9 Maximumcollectortemperature,collectorarray2(°C)
A : 1 0 Hoursrun,solarcircuitpump1(h)
A : 1 1 Hoursrun,solarcircuitpump2(h)
A : 1 2 Currentoutput(kW)
A : 1 3 Currentdayyield(kWh)
A : 1 4 Totalyield(Wh)
A : 1 5 Totalyield(kWh)
A : 1 6 Totalyield(MWh)
A : 1 7 Solarheatingstatus,cylinder1
(0=unsuccessful, 1=successful)
A : 1 8 Solarheatingstatus,cylinder2
(0=unsuccessful, 1=successful)
A : 1 9 MaximumDHWtemperature,solarcylinder3(°C)
A : 2 0 Hoursrun,solarcircuitpump3(h)
A : 2 1 Solarheatingstatus,cylinder3
(0=unsuccessful,1=successful)
*AssignmentofinputsE1andE3subjecttothecongurationselectedattheSM2.
Display values used with
SM2 solar module
Note:DisplayA19toA21onlyeffectivefromsoftwareversion
SM1/SM2228_04.
Display level

10 3061916_0611
SM1: Thecurrenttemperatureofthesolarcylinderatthelevelof
thesolarindirectcoilisdisplayed.
SM2: Thecurrenttemperatureofsolarcylinder1atthelevelof
thesolarindirectcoilisdisplayed.
A : 0 1
SM1: Actual
DHWtemperature
Solarcylinder
SM2: DHW
Actualtemperature
Solarcylinder1
SM1: ThemaximumDHWtemperatureoverthecourseof24hours
isdisplayed.
SM2: The maximum DHW temperature of cylinder 1 over the
courseof24hoursisdisplayed.
Thisvalueisresetevery24hours.
A : 0 2
SM1: Maximum
DHWtemperature
Solarcylinder
SM2: Maximum
DHWtemperature
Solarcylinder1
SM1: Thecurrenttemperaturecapturedattheoutlet(ow)ofthe
collectororcollectorarrayisdisplayed.
SM2: Thecurrenttemperaturecapturedattheoutlet(ow)ofthe
collectororcollectorarray1isdisplayed.
A : 0 3
SM1: Collectortemperature
SM2: Collectortemperature,
collectorarray1
SM1: The maximum collector temperature over the course of
24hoursisdisplayed.
SM2: The maximum collector temperature of collector array 1
overthecourseof24hoursisdisplayed.
Thisvalueisresetevery24hours.
A : 0 4
SM1: Maximumcollector
temperature
SM2: Maximumcollector
temperature
Collectorarray1
SM1: Thecurrenttemperatureofthesolarcircuitreturnisdisplayed.
Thisvalueisrequiredforcalculatingtheyield.
SM2: The current value captured by the sensor connected
to input E1 is displayed. Subject to the conguration
set at the SM2, this may be the return temperature, the
actual DHW temperature of solar cylinder 2, the actual
DHW temperature of solar cylinder 3 or the heating
temperature.
Thisvaluewillonlybedisplayedifatemperaturesensor
hasbeenconnected.
A : 0 5
SM1: Returntemperature
SM2: InputE1
SM1/ Thecurrentowrateinl/min(litresperminuteisdisplayed.
SM2: This display is only shown if value 1 or 2 has been
selectedforparameter08(capturingtheamountofheat).
Thisvalueisrequiredforcalculatingtheyield.
A : 0 6
Solarcircuitowrate
Description of the display values
Display level
Inhaltsverzeichnis
Andere Wolf Steuereinheit Handbücher

Wolf
Wolf R33/4 DigiComfort (Theta) Kurzanleitung

Wolf
Wolf BML-EXCELLENT Handbuch

Wolf
Wolf Link home Bedienungsanleitung

Wolf
Wolf RK-2 Kurzanleitung

Wolf
Wolf 3064055-201508 Bedienungsanleitung

Wolf
Wolf BML Bedienungsanleitung

Wolf
Wolf BMK Bedienungsanleitung

Wolf
Wolf SW MV Bedienungsanleitung

Wolf
Wolf OBC Bedienungsanleitung

Wolf
Wolf CGL Stücklistenhandbuch
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung