Wuhan Guide GUIDIR IR529 Bedienungsanleitung

User Manual
1
Handheld Thermal Binocular Viewer
GUIDIR®IR529
User Manual
Wuhan Guide Infrared Technology Co., Ltd.
No. 26 Shucheng Rd, Hongshan District, Wuhan 430070 P. R. China
Telephone: +86-27-8767 1991
Facsimile: +86-27-8767 1927
Internet: www.guide-infared.com
© Wuhan Guide Infrared Technology Co., Ltd., 2006
Publication No: IR529 UM 002

User Manual
2
The Quality Management System of Wuhan Guide Infrared Technology Co., Ltd. is approved to
ISO9001:2000 for the design and manufacture, stockholding, in-house repair and site servicing of
non-contact temperature measuring instrumentation.
Wuhan Guide Infrared Technology Co., Ltd. reserves the right to make changes and
improvements on any of the products described in this manual without prior notice.
GUIDIR®IR529 Handheld Thermal Binocular Viewer complies with current
European directives relating to electromagnetic compatibility and safety. (EMC
directive 89/336/EEC; Low voltage directive 73/23/EEC)
Copyright
© Wuhan Guide Infrared Technology Co., Ltd, 2006. All rights reserved worldwide. No parts of the
products may be reproduced, transmitted, transcribed or translated into any language or computer
language in any form or by any means, electronic, magnetic, optical, manual or otherwise, without
the prior written permission of Wuhan Guide Infrared Technology Co., Ltd.
This manual must not, in whole or part, be copied, photocopied, reproduced, translated or
transmitted to any electronic medium or machine readable form without prior consent, in writing,
from Wuhan Guide Infrared Technology Co., Ltd.

User Manual
3
Contents
Contents .........................................................................................................................................3
Introduction.....................................................................................................................................4
Precautions.....................................................................................................................................4
Maintenance ...................................................................................................................................5
Calibration and Repair Philosophy..................................................................................................5
Technical Specifications..................................................................................................................6
System Configuration .....................................................................................................................7
Parts Described ..............................................................................................................................7
Quick Start Guide ...........................................................................................................................9
Operating the System.....................................................................................................................9
Battery Charging...........................................................................................................................19
Non Uniformity Calibration (NUC).................................................................................................20
Troubleshooting ............................................................................................................................20

User Manual
4
Introduction
This publication provides the necessary information required to safely operate the GUIDIR®IR529
Handheld Thermal Binocular Viewer.
It is important to fully check all equipment with which you have been supplied
The equipment should be used, maintained and serviced by suitably trained personnel, capable of
carefully following the procedures and guidelines given in this User Manual
All User Manuals and leaflets should be read thoroughly before proceeding with operation of the
equipment
It is also advisable that all User Manuals and Instruction Leaflets supplied are kept readily available,
for reference when the equipment is in general use
Precautions
The following precautions must be adhered to at all times and must be considered in addition to
any advised precautions issued at the relevant worksite or work area
•Do not use the GUIDIR®IR529 Handheld Thermal Binocular Viewer in temperature
exceeding its working and storage temperature ranges
•When the GUIDIR®IR529 Handheld Thermal Binocular Viewer is not in use or is to be
transported, ensure that the unit is stored in the protective carry case
•The GUIDIR®IR529 Handheld Thermal Binocular Viewer incorporates precision optical
equipment and static-sensitive electronics which should be protected from shock and
vibration at all times
•Do not attempt to open the camera body, as this action will void the warranty
•Do not connect or disconnect the cables without switching off the power supply

User Manual
5
Maintenance
To ensure that the GUIDIR®IR529 Handheld Thermal Binocular Viewer is kept in good working
condition and remains fully operational, the following guidelines should be adhered to at all times
Non-optical surfaces
The non-optical surfaces of the camera can be cleaned when required, with a soft cloth dampened
with water and a mild detergent
Optical surfaces
The optical surfaces of the camera lens should only be cleaned when visibly dirty. Care should be
taken to avoid touching the exposed lens surface, as skin acid left behind from fingerprints can be
damaging to coatings and lens substrates. Use only a proprietary lens cleaning tissue
Calibration and Repair Philosophy
To ensure the accuracy and reliability of the GUIDIR®IR529 Handheld Thermal Binocular Viewer, it
is highly recommended that the instrument be calibrated at 12 monthly intervals
Calibration or repair for the instrument can be obtained by either contacting the address/ telephone
number on the cover of this User Manual, or by email to the following addresses:
Caution
The GUIDIR®IR529 Handheld Thermal Binocular Viewer does not incorporate any user serviceable
parts. Never attempt to disassemble or modify the camera. Opening the unit invalidates the
warranty

User Manual
6
Technical Specifications
Imaging performance
Detector Uncooled FPA Microbolometer, 384X288 pixels, 35μm
Spectral Response 8~14μm
NETD 0.08ºC@25ºC [Typical]
FOV/ Focus: 5.5°×4.1°/ 140mm
Image Presentation
Video Output PAL/NTSC
Integrated Display: 2 OLED viewfinders
Image Color: White heat, black heat, 256 level (9 palettes optional)
Offset & Gain Control Automatic/ Manual
Electronic Zoom 2X
Power System
Battery Type: 7.2V rechargeable Li-ion battery
Battery Operating Time: >2 hours
External Power Supply: AC adapter, 110/220 VAC, 50/60Hz
Power Dissipation: <4.5 watts
Physical Characteristics
Size 290mm×140mm×144m
Weight 2.0Kg
Tripod Mounting: 1/4”-20
Interface
Video output/ Power Composite video output/ power input
Environmental Specifications
Operating temperature -20ºC~50ºC
Storage temperature -40ºC~60ºC
Humidity: <80%RH
Shock: GJB150-86
Vibration: GJB150-86

User Manual
7
System Configuration
•IR529 Camera with GPS, digital compass
•Two OLED viewfinders
•Video cable
•Power cable & AC adapter
•Two batteries
•Battery charger & AC adapter
•Test certificates
•User manual
•Transportation case
Parts Described
Side View
IR lens
Camera body
Antenna for GPS

User Manual
8
Back View
Buttons on Camera Body
Hand strap
Viewfinder
Button power
Battery slot
Button Calibration
Button menu Button +Button -
Viewfinder

User Manual
9
Video/ Power Interface
Quick Start Guide
1. Insert a fully charged battery into the camera
2. Power on the camera and uncover the lens cap after 15 seconds
3. Adjust the two OLED viewfinders to a satisfying extent
4. Adjust focus till getting a clear live image
5. Use the buttons to adjust imaging performance or get position information
6. Press button C to perform non-uniformity calibration when necessary
7. Power off the camera and remove the battery
8. Store the whole system in good conditions
Operating the System
Powering on the camera
Power on the GUIDIR®IR529 camera, the boot screen image below will appear immediately.

User Manual
10
After the image above ends, the camera will do non-uniformity calibration automatically.
Adjusting the viewfinders
Adjust dioptre of the viewfinders till you see the image clearly and your eyes feel comfortably
The ideal effect is that you see only one image in the two viewfinders
Focusing
The 140mm lens is motorized focusing, thus the camera incorporates a focus control motor for
focusing
yWhen there is no menu on the live image, press button + and –to focus
yIf there is menu displayed on the live image, press button M till exiting the menu and then
press button + and –to focus
Using the camera menu
When there is no menu on the live image, pressing button M on the camera body will bring up the
menu as shown below or the battery status.
The menu offers seven options: Option B, Option C, Option A, Option Z, Option P, Option GPS and
Option Compass. The seven options can be classified into two types: function options to adjust
Brightness Contrast Auto Zoom Palette GPS Digital
compass
Function options Status options
Inhaltsverzeichnis