Wyse V10LE Bedienungsanleitung

Installation Guide
Wyse®VX0LE Conversion to WES2009
Wyse®USB Firmware ToolTM Release 1.13
Products: V10LE, V30LE, V50LE, V90LE
Issue: 060811
PN: 883887-26L Rev. A

Copyright Notices
© 2011, Wyse Technology Inc. All rights reserved.
This manual and the software and firmware described in it are copyrighted. You may not reproduce, transmit,
transcribe, store in a retrieval system, or translate into any language or computer language, in any form or by any
means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, any part of this publication
without express written permission.
End User License Agreement (“License”)
A copy of the Wyse Technology End User License Agreement is included in the software and provided for your
reference only. The License at http://www.wyse.com/license as of the purchase date is the controlling licensing
agreement. By copying, using, or installing the software or the product, you agree to be bound by those terms.
Trademarks
The Wyse logo and Wyse are trademarks of Wyse Technology Inc. Other product names mentioned herein are for
identification purposes only and may be trademarks and/or registered trademarks of their respective companies.
Specifications subject to change without notice.
Restricted Rights Legend
You acknowledge that the Software is of U.S. origin. You agree to comply with all applicable international and
national laws that apply to the Software, including the U.S. Export Administration Regulations, as well as end-user,
end-use and country destination restrictions issued by U.S. and other governments. For additional information on
exporting the Software, see http://www.microsoft.com/exporting.
Ordering Information
For availability, pricing, and ordering information in the United States and Canada, call 1-800-GET-WYSE
(1-800-438-9973) or visit us at http://www.wyse.com. In all other countries, contact your sales representative.

Contents
1 Introduction 1
Kit Contents 1
Overview 2
Wyse Technical Support 2
Related Documentation and Services 2
Wyse Online Community 2
2 Installing Flash and RAM 3
Requirements 3
Procedures 4
What’s Next 6
3 Installing WES2009 Firmware 7
Requirements 7
Procedures 8
Troubleshooting 13
USB Keys - Troubleshooting Boot Issues 13
SanDisk Cruiser Flash Drives - Troubleshooting Partition Issues 13

iv Contents
This page intentionally blank.

1Introduction
This guide provides the instructions you need to use Wyse®USB Firmware Tool to convert
the following Wyse VX0LE cloud clients to WES2009:
• V10LE
• V30LE
• V50LE
• V90LE
Caution
WES2009 firmware requires VX0LE cloud clients to have a minimum of 2 GB
flash and 1 GB RAM.
Note
After converting your cloud clients, obtain any available firmware update at
http://www.wyse.com/serviceandsupport/support/downloads.asp.
Kit Contents
The conversion kit includes:
•Conversion Software Assembly DVD-ROM
•Flash module
•RAM module
•Thermal pad
•Wyse Conversion Labels (you must attach a Wyse label to each converted cloud
client)
•Microsoft License Labels (you must attach a COA label to each converted cloud client)
Figure 1 Kit contents (items may look different or not be included in your kit)

2Chapter 1
The Conversion Software Assembly DVD-ROM contains:
•A PDF of this Reference Guide
•Wyse USB Firmware Tool v1.13
•VX0LE 2GB WES Conversion Image folder containing the following files:
·bios.img
·cmos.img
·commandsXml.xml
·BA.img
·initrd.pxe
·mbr.img
·par1.img
·vmlinuz
Overview
To convert your cloud clients to WES2009:
1. (Optional) If you need to perform a hardware installation (install new flash or RAM),
complete "Installing Flash and RAM."
2. (Required) Complete "Installing WES2009 Firmware."
Wyse Technical Support
To access Wyse technical resources, visit http://www.wyse.com/support. If you still have
questions, you can submit your questions using the Wyse Self-Service Center at
http://support.wyse.com/selfservice.html or call Customer Support at 1-800-800-WYSE
(toll free in U.S. and Canada). Hours of operation are from 6:00 A.M. to 5:00 P.M. Pacific
Time, Monday through Friday.
To access international support, visit http://www.wyse.com/global.
Related Documentation and Services
Fact Sheets containing the features of hardware products are available on the Wyse Web
site. Go to http://www.wyse.com/products/hardware, click the link for your hardware
product, and then click the link for the Fact Sheet.
Administrator and other documentation for your cloud client model are available at:
http://www.wyse.com/manuals.
Wyse Online Community
Wyse maintains an online community where users of our products can seek and exchange
information on user forums. Visit the Wyse Online Community forums at:
http://community.wyse.com/forum.

2Installing Flash and RAM
This chapter contains information for Wyse V10LE, V30LE, V50LE and V90LE cloud client
users who must install new flash and RAM. If you are installing firmware only, you can skip
this chapter and proceed to "Installing WES2009 Firmware."
Caution
(V90LE Only) For V90LE users who do not have a minimum of 2 GB flash,
you must install new flash (all V90LE users have 1 GB RAM and can skip
"Step 3: Install the RAM Module"). For V90LE users who have a minimum of
2 GB flash and 1 GB RAM, skip this chapter and continue with "Installing
WES2009 Firmware."
Requirements
• Small Phillips screwdriver
• Small Flat-Edge screwdriver
Warning
Flash and RAM modules may be susceptible to damage by Electro-Static
Discharge (ESD). All industry-standard cautions should be followed to avoid
ESD. Before you remove or install a module, touch any metal part of the
chassis and keep that contact with the chassis during the installation
process.

4Chapter 2
Procedures
Step 1: Remove the Top Cover
Caution
Follow all precautions listed in the Quick-Start Guide that came with your
cloud client for disconnecting and reconnecting the cloud client.
1. Perform a proper shutdown of the cloud client by closing all files and ending your
session, and then press the power button to turn off the cloud client.
2. Unplug the power cord and power adapter, remove all of the cables from the rear of the
cloud client, and then detach any vertical foot.
3. Position the cloud client horizontally, remove the two screws from the rear of the cloud
client using a small Phillips screwdriver.
Figure 2 Removing the rear screws
4. Remove the top cover from the cloud client by inserting the tip of a small Flat-Edge
Screwdriver just inside the edge of the lock receptacle to make contact with the metal
liner that lines the opening. Apply pressure inward and downward on the metal liner
while pulling up on the plastic housing until it releases as shown in Figure 3.
Figure 3 Removing the top cover
5. Lift the top cover to remove it and expose the main board as shown in Figure 4. Notice
that the rear of the cloud client is positioned at the bottom of the photo.

Installing Flash and RAM 5
Step 2: Install the Flash Module
Warning
Flash modules may be susceptible to damage by Electro-Static Discharge
(ESD). All industry-standard cautions should be followed to avoid ESD.
Before you remove or install a module, touch any metal part of the chassis
and keep that contact with the chassis during the installation process.
1. Note where the connector of the flash module is located in Figure 4. Remove the
existing flash module from the socket.
Figure 4 Removing the existing flash module
2. Install the new flash module in the reverse order of removing the original flash module
making sure to align the plastic tab of the module’s connector with the notch in the
connector on the board.
Step 3: Install the RAM Module
Warning
RAM modules may be susceptible to damage by Electro-Static Discharge
(ESD). All industry-standard cautions should be followed to avoid ESD.
Before you remove or install a module, touch any metal part of the chassis
and keep that contact with the chassis during the installation process.
1. Note where the connector of the RAM module is located in Figure 5. Remove the
existing RAM module. Use your fingers to unlock the two retaining clips at either side of
the RAM module by pushing in the direction of the arrows shown in Figure 5. The
module should pop up from its socket. Lift out the RAM module.
Figure 5 Removing the existing RAM module

6Chapter 2
2. Install the thermal pad by peeling off the clear strip and placing it (with textured strip
facing up as shown in Figure 6) where the module was located. Make sure that the pad
does not interfere with the connector pins or module locking clamps, and then lightly
press to secure.
Figure 6 Installing thermal pad
3. Peel off the colored textured strip from the thermal pad as shown in Figure 7, and then
with its label facing down, install the new RAM module in the reverse order of removing
the original RAM module. Carefully press down on the RAM module until its retaining
clips lock it into place.
Figure 7 Installing new RAM module
Step 4: Reassemble the Cloud Client
1. Replace the top cover in the reverse order as described in "Step 1: Remove the Top
Cover."
2. Attach any vertical foot.
3. Reconnect the video display, keyboard, mouse, network cable, and power adapter to
the cloud client before connecting to an electrical outlet.
Caution
Do not turn on the cloud client. The cloud client is ready to re-image,
however the flash module does not contain an operating system. Turning on
power to your cloud client without firmware will display the error message
“NO OPERATING SYSTEM FOUND.”
What’s Next
Continue with "Installing WES2009 Firmware."