A&D AD-4412-CW Bedienungsanleitung

AD-4412-CW
Weighing Indicator
CONNECTION SETTING EXAMPLE
1WMPD4004155

© 2020 A&D Company, Limited. All rights reserved.
No part of this publication may be reproduced, transmitted, transcribed, or translated into any
language in any form by any means without the written permission of A&D Company, Limited.
The contents of this manual and the specifications of the instrument covered by this manual are
subject to change for improvement without notice.

AD4412-CW 3
This section shows descriptions from connection to basic settings for using the AD-4412-CW as a weight checker.
Setting flow Instruction manual
“ ” shows the instruction
manual section referenced..
Connecting
Setting the weighing unit, decimal
point position and division
Connecting to external
equipment
Connecting to the indicator
Setting the weighing capacity
Adjusting the weight
Setting the conveyer length
Configuring settings
for theproducts
Setting the speed
Configuring settings
for the indicator
Setting the photo eye sensor
Setting the detect basis
Setting the product length
Refer to "3. Installing the
Weighing Indicator" for
details of connection.
Refer to "11. Interface" for
other external equipments.
Refer to "6.1. Calibrating the
Indicator using a Weight",
"9.12.Weighing" and "9.13.
Cal (Calibration)" for details
of scale settings.
Refer to "5.6.4. Setting the
Digital Output (DO)",
"9.4.DO Map (Digital Output
Map)" and "9.5.Control I/O
(Part of Digital Output) " for
details of DO settings.
Refer to "9.18.Control I/O
(Part of Digital Input)" for
details of DI settings.
Refer to "9.1. Product name/
product code" to "9.7. Tare"
for details of product settings.
Refer to "5.6.2. Settings of
Threshold Values ( Target,
HiHi Limit, Hi Limit, Lo Limit,
LoLo Limit )" and
"9.2. Detect basis" for
details of detect basis.
Setting the DO and DI

4 AD4412-CW
Fig. 1 Rear panel
1. Connecting
1.1. Connecting to the indicator
The following describes how to connect the indicator to the load cell.
Follow the procedure below for the indicator connection.
1. Connect the load cell cable to the “LOAD CELL” terminal (Fig. 2), the indicator’s power cable to the “AC IN” terminal
(Fig. 3), both located on the rear panel of the indicator. (Refer to “3.4. Connecting Load Cell Cables” and “3.5.
Connecting Power Lines” in the instruction manual.)
2. When using the photo eye sensor, connect it to the “I/F” terminal on the rear panel of the indicator. (Refer to
“Connection of Photo eye Sensor” of “11. Interface” in the instruction manual.)
I/F terminal
Load cell terminal
Power terminal
Control I/O
• AD-4412-CW 6-wire shielded load cell cable Load cell
1 EXC+ Positive power supply to load cell EXC+
2 SEN+ Positive sense input
3 SEN- Negative sense input
4 EXC- Negative power supply to load cell EXC-
5 SIG+ Positive input from load cell SIG+
6 SIG- Negative input from load cell SIG-
7 SHLD Shield
Usable Compression Terminal Parts (M3)
1.0
3.2
Fig. 2 Standard connection method for load cell (6-wire)

AD4412-CW 5
Warning
Ground the indicator to avoid an electric shock or operation error. If the indicator is not grounded, it may cause an
electric shock or malfunction due to discharge of static electricity.
Live terminal
Neutral terminal 100-240 V
~
, 50Hz or 60Hz
Noiseless stable single phase power source
PE terminal
Ground
Usable Compression Terminal Parts (M4)
1.0
4.3
Fig. 3 Connecting power lines

6 AD4412-CW
1.2. Connecting the external equipment
This section describes the specifications and connection examples for control I/O.
Control I/O specifications
Control I/O has DO11 points, DI11 points, and the following specifications.
Ta b l e 1 Control I/O Interface specifications
Input circuit (DI) method Non-voltage input/open collector drive
Input terminal open valtage 7 to 11 V
Input circuit drive current 5 mA (max.)
Max. residual voltage 2V (max.)
Output circuit (DO) method Open collector
Output circuit withstand
voltage
DC 40 V
Max. drive current 50 mA
Output terminal residual
voltage
1.5 V (at drive current 50 mA)
Connecting the control I/O
Refer to the following figure for connecting the control I/O.
Fig. 4 Input and output circuit of control I/O
Relay (with protection diode)
Photo coupler
Mechanical relay
Open collector
Max. 5 mA Recommended drive circuit
Output common B12
Max. drive current 50 mA
internal circuit
Input common A12
Recommended drive circuit
Be sure to attach protection
diode to inductive loads such as
rela
y
and solenoid coil.
Max. DC 40 V

AD4412-CW 7
Fig. 5 Terminal numbers of control I/O connector
Fig 1 OP-02 connector terminal
Ta b l e 2 Correspondence table of control I/O and DI/DO
* Optional OP-02 Relay output and OP-05 parallel I/O can be installed in the indicator for a total of up to two units.
However, corresponding numbers for the DI/DO vary depending on the slot installed to.
Installing the OP-02 Relay output into optional slot 1 allows use of DO12 to DO20. Installing the OP-02 Relay output into
optional slot 2 allows use of DO28 to DO36. (Refer to “11.5. OP - 02 Relay output” in the instruction manual for details.)
Table 3 Correspondence table of OP-02 and DO
Input terminal DI number Output terminal DO number
A1 DI 1 B1 DO 1
A2 DI 2 B2 DO 2
A3 DI 3 B3 DO 3
A4 DI 4 B4 DO 4
A5 DI 5 B5 DO 5
A6 DI 6 B6 DO 6
A7 DI 7 B7 DO 7
A8 DI 8 B8 DO 8
A9 DI 9 B9 DO 9
A10 DI 10 B10 DO 10
A11 DI 11 B11 DO 11
A12
(
input common
)
B12
(
output common
)
Output terminal DO number
( optional slot 1)
DO number
( optional slot 2)
1
c
h
1 DO 12 DO 28
2 DO 13 DO 29
3 DO 14 DO 30
4 DO 15 DO 31
5 DO 16 DO 32
6
(
output common
)
(
output common
)
2
c
h
7 DO 17 DO 33
8 DO 18 DO 34
9 DO 19 DO 35
10 DO 20 DO 36
11
(
output common
)
(
output common
)
OP-02
2ch 1ch
Screw hole
When installing the OP-02 to the
indicator, be sure that the screws are
firmly tightened.

8 AD4412-CW
Fig 2 OP-05 Connector terminal number
Installing the OP-05 Parallel I/O to optional slot 1 allows use of DI12 to DI27 and DO12 to DO27. Installing the OP-05
Parallel I/O to optional slot 2 allows use of DI28 to DI43 and DO28 to DO43.
(Refer to “11.6. OP - 05 Parallel Input/Output” in the instruction manual for details.)
Ta b l e 4 Correspondence table of OP-05 and DI/DO
Input
terminal
DI number
(optional slot 1)
DI number
(optional slot 2)
Output
terminal
DO number
(optional slot 1)
DO number
(optional slot 2)
A1 DI 12 DI 28 B1 DO 12 DO 28
A2 DI 13 DI 29 B2 DO 13 DO 29
A3 DI 14 DI 30 B3 DO 14 DO 30
A4 DI 15 DI 31 B4 DO 15 DO 31
A13 DI 24 DI 40 B13 DO 24 DO 40
A14 DI 25 DI 41 B14 DO 25 DO 41
A15 DI 26 DI 42 B15 DO 26 DO 42
A16 DI 27 DI 43 B16 DO 27 DO 43
A17
(
input common
)
(
input common
)
B17
(
output common
)
(
output common
)
A18
(
input common
)
(
input common
)
B18
(
output common
)
(
output common
)
A19
(
input common
)
(
input common
)
B19
(
output common
)
(
output common
)
A20 (FG) (FG) B20 (FG) (FG)
Screw hole
When installing the OP-05 to the
indicator, be sure that the screws are
firmly tightened.
OP-05
B1 B20
A1 A20

AD4412-CW 9
Connection example
The following shows a general connection example for the indicator. The following settings are described based on this
example.
Othrer specifications
- Scale weighing capacity: 1000 g
- Conveyer length : 300 mm
- Conveyer speed : 80 m/min
Relay
Conveyer
Fig. 8 Connection example
A
D-4412-CW
To we r li gh
t
DO2 DO1
B2 B1
Load cell
Photo eye sensor

10 AD4412-CW
2. Setting the indicator
By changing the factory settings for the indicator, it can be changed to have the appropriate settings for your scale.
The parameters set are maintained in the memory even after shutting down the power of the indicator until the
indicator is initialized or those settings are changed. The following settings require quality manager or higher
permissions. (Refer to “5.5 Managing User Level for Logging In” of the instruction manual for setting the management
level.)
2.1. Weighing unit, decimal point position and division
1. Touch the Setting key on the weighing screen to display the setting screen.
2. Touch the Weighing button on “Balance” tab and set the weighing unit, decimal point position and division for
weighing products into the each field on “Weighing Setting 1” tab.
Fig. 10 Setting the weighing unit, decimal point position and division
Fig. 9 Setting screen
Inhaltsverzeichnis
Andere A&D Messgerät Handbücher

A&D
A&D AD-4212A-100 Bedienungsanleitung

A&D
A&D AD-4531B Bedienungsanleitung

A&D
A&D AD-1611 Bedienungsanleitung

A&D
A&D RA3100 Omniace Bedienungsanleitung

A&D
A&D FX-i Series Bedienungsanleitung

A&D
A&D MF-50 Bedienungsanleitung

A&D
A&D AD-4407A Bedienungsanleitung

A&D
A&D AD-4530 Bedienungsanleitung

A&D
A&D Omniace III RA2300A Bedienungsanleitung

A&D
A&D LCC07 Series Bedienungsanleitung