ACS SAF'IR EVOLUTION Bedienungsanleitung

Instruction manual
EVIDENTIAL ANALYSER
SAF’IR EVOLUTION
TM

SAF’IR EVOLUTION
PORTABLE ETHYLOMETRE CERTIFIED
ACCORDING TO THE OIML R 126

National approval
This device conforms to the model specications of DOT
Alcohol Countermeasure Systems Corp
60 International Boulevard
Toronto, Ontario M9W 6J2 CANADA
T +1 416 619 3500
F +1 416 619 3501
acs-corp.com
ALCOLOCK UK
T 00447891667047
alcolock.co.uk
OIML R126/1998-ES1-09.02
Compliance certication issued by:
Centro Español de Metrología
C/ Alfar, 2 – 28760 Tres Cantos Madrid SPAIN
ACS, ALCOHOL COUNTERMEASURE SYSTEMS, SAF’IR and the “Molly” are trademarks
of Alcohol Countermeasure Systems (International) Inc. and are used under license.
Alcohol Countermeasure Systems is the trading style of Alcohol Countermeasure Systems
(International) Inc.
© 2016 Alcohol Countermeasure Systems Corp
The information disclosed in this document is the valuable property of Alcohol Countermeasure
Systems and all copyright and other proprietary rights to this document are reserved. No
reproduction of this document is permitted without the prior written consent of Alcohol
Countermeasure Systems.


The SAF’IR EVOLUTION is a portable ethylometre that is certied according
to the International Recommendation R.126 of the International Organization
of Legal Metrology concerning ethylometres, 1998 Edition.
The SAF’IR EVOLUTION measures the concentration of ethanol in exhaled
breath. Numerous studies carried out worldwide have shown that the ratio
of blood alcohol concentration (BAC) to exhaled alveolar breath alcohol
concentration (BrAC) is a constant.
The SAF’IR EVOLUTION is a self-contained, portable instrument that may
be used either indoors or outdoors. The results of the tests present evidential
accuracy and the printed conrmation may be used in court, according to the
local regulations.
Terms used in this manual:
BrAC = breath alcohol concentration
BAC = blood alcohol concentration
Legal limit = set according to each country’s local regulations

TABLE OF CONTENTS
Safety and precautions........................................................................ 1
Validity label ........................................................................................ 2
Seal ..................................................................................................... 2
Using the SAF’IR Evolution ..................................................................... 3
First use ............................................................................................... 3
Power up sequence............................................................................. 4
Inserting the mouthpiece ..................................................................... 5
Test ...................................................................................................... 5
Notes ................................................................................................... 8
Turning off ......................................................................................... 10
Measurement principle ...................................................................... 11
Monitoring exhalation ow ................................................................. 11
Standby mode ................................................................................... 11
Menu options .......................................................................................... 12
Recalling a test result ........................................................................ 12
Passive detection .............................................................................. 13
Menu conguration ............................................................................ 14
Display Contrast ......................................................................... 15
Printer test .................................................................................. 15
Printing the results............................................................................. 15
Installing the printer battery ........................................................ 16
Charging the printer battery ....................................................... 16
Loading the paper roll ................................................................ 16
Printer LED status code ............................................................. 16
Printer LED error code ............................................................... 17
Functioning ............................................................................................. 17
Operating icons ................................................................................. 17
Accessories ....................................................................................... 18
Replacement parts ............................................................................ 18
Technical specications ........................................................................ 19
Storage conditions............................................................................. 19
Operating temperature ...................................................................... 19
Periodic inspections .......................................................................... 19
Battery life ......................................................................................... 19
Warm-up time .................................................................................... 19
Size and weight ................................................................................. 20

Measuring range ............................................................................... 20
Results .............................................................................................. 20
Date and time format ......................................................................... 20
Troubleshooting ..................................................................................... 21
Error messages ................................................................................. 21
Warranty ............................................................................................ 21
Maintenance ...................................................................................... 21
Recycling ........................................................................................... 22
ACS and the environment ................................................................. 22

SAF’IR EVOLUTION
1
SAFETY AND PRECAUTIONS
Take the following precautions to ensure smooth and uninterrupted use of the
SAF’IR EVOLUTION:
• Use this device for its intended purpose only
• Do not open the SAF’IR EVOLUTION’s case or the printer (when
provided). Doing so will void the warranty and may also damage the
internal components
• Follow the instructions displayed on the front label of the device prior to
taking a test
NOTE: If the subject undergoing the test has ingested alcohol
recently, some trace amounts may reside in the upper respiratory
tract, causing a misleading result. The SAF’IR EVOLUTION is
designed to detect mouth alcohol and displays a cycle error message
in such a case.
• Use a new mouthpiece for each test
• It is also advisable to use the SAF’IR EVOLUTION with the provided pouch

INSTRUCTION MANUAL 2
VALIDITY LABEL
The validity label conrms that the initial or periodic verication has been
performed by an authorized laboratory and notes the verication expiry date.
The label is placed on the right side of the instrument and is to be removed
only at an authorized laboratory. No measurement should be carried out if the
validity period has expired.
SEAL
The seal afxed to the back of the instrument warrants the proper working
order of the instrument and may be removed only by an authorized agency. No
measurement should be carried out if the seal is missing or damaged.
Validity label
Seal

SAF’IR EVOLUTION
3
USING THE SAF’IR EVOLUTION
FIRST USE
Ensure that the battery is fully charged before using the device for the rst
time.
Use the AC adapter provided to recharge the battery, as shown below:
Connect to the main supply
Andere Handbücher für SAF'IR EVOLUTION
1
Inhaltsverzeichnis
Andere ACS Messgerät Handbücher

ACS
ACS A1040 MIRA Bedienungsanleitung

ACS
ACS PenGauge A1207 Bedienungsanleitung

ACS
ACS A1210 Bedienungsanleitung
ACS
ACS Fluxicont FP Bedienungsanleitung

ACS
ACS G series Bedienungsanleitung

ACS
ACS A1270 EMAT Bedienungsanleitung

ACS
ACS A1207D Bedienungsanleitung

ACS
ACS A1270 EMAT Bedienungsanleitung

ACS
ACS PenGauge A1207 Bedienungsanleitung

ACS
ACS USD 050 Bedienungsanleitung