AGFA CR 10-X Bedienungsanleitung

CR 10-X, CR 12-X, CR 15-X
5151/100
5151/200
5151/300
User Manual
CR10-X
CR12-X
CR15-X
2491E EN 20150409 1543

Contents
Legal Notice ..........................................................................4
Introduction .......................................................................... 5
Introduction to this Manual ....................................... 6
Scope .............................................................7
About the safety notices in this document ...... 8
Disclaimer ..................................................... 9
Introduction to CR 10-X, CR 12-X and CR 15-X .......... 9
Intended Use ............................................... 10
Indications for Use .......................................11
Intended User .............................................. 12
Configuration .............................................. 13
Operation Controls ...................................... 15
System Documentation ................................17
Training .......................................................18
Product Complaints ..................................... 19
Compatibility ...............................................20
Compliance ................................................. 21
Connectivity ................................................ 23
Installation .................................................. 24
Labels .......................................................... 26
Cleaning and Disinfection ............................29
Patient data security .................................... 30
Maintenance ................................................31
Recurrent safety tests ...................................32
Environmental protection ............................ 33
Safety Directions ..........................................34
Quality Control ............................................37
Getting started .....................................................................38
Starting the Digitizer ............................................... 39
Basic Workflow ........................................................40
Step 1: Select a patient and start the exam ... 41
Step 2: Digitize the image ............................ 42
Step 3: Perform a quality control ..................45
Step 4: Remove the cassette and insert the next
one .............................................................. 46
Stopping the Device .................................................47
Before Switching Off ....................................48
Switching Off ...............................................49
Operating CR 10-X, CR 12-X and CR 15-X ............................ 50
Reading an Emergency Image Plate ......................... 51
Re-erasing an Image Plate ........................................52
Reading the Initialization Data of an Image Plate .....54
Expiry of Image Plates ..............................................57
Upcoming Expiry of the Image Plate ............ 58
Expired Image Plate .....................................58
2 | CR 10-X, CR 12-X, CR 15-X | Contents
2491E EN 20150409 1543

Troubleshooting ...................................................... 59
Digitizer Remote Display ............................. 60
Connection Problems ...................................61
Cassette Could Not Be Identified ..................62
Cassette release button pressed before end of cycle
..........................................................................63
Cannot read data on the image plate ............64
Image Plate Transport Problems .................. 65
Removing a Jammed Image Plate ................ 66
Behavior in Case of Power Failure ................70
Cleaning the Optical Unit .............................71
Technical Data .....................................................................73
Specifications .......................................................... 74
Cassette formats ...................................................... 78
Remarks for HF-emission and immunity .............................. 79
Remarks for HF-emission and immunity .................. 79
CR 10-X, CR 12-X, CR 15-X | Contents | 3
2491E EN 20150409 1543

Legal Notice
0413
Agfa HealthCare NV, Septestraat 27, B-2640 Mortsel - Belgium
For more information on Agfa products and Agfa HealthCare products, please
visit www.agfa.com.
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium or
its affiliates. CR 10-X, CR 12-X, CR 15-X, NX, ADC QS and ADC VIPS are
trademarks of Agfa HealthCare N.V., Belgium or one of its affiliates. All other
trademarks are held by their respective owners and are used in an editorial
fashion with no intention of infringement.
Agfa HealthCare N.V. makes no warranties or representation, expressed or
implied, with respect to the accuracy, completeness or usefulness of the
information contained in this document and specifically disclaims warranties
of suitability for any particular purpose. Products and services may not be
available for your local area. Please contact your local sales representative for
availability information. Agfa HealthCare N.V. diligently strives to provide as
accurate information as possible, but shall not be responsible for any
typographical error. Agfa HealthCare N.V. shall under no circumstances be
liable for any damage arising from the use or inability to use any information,
apparatus, method or process disclosed in this document. Agfa HealthCare
N.V. reserves the right to make changes to this document without prior notice.
The original version of this document is in English.
Copyright 2015 Agfa HealthCare N.V
All rights reserved.
Published by Agfa HealthCare N.V.
B-2640 Mortsel - Belgium.
No part of this document may be reproduced, copied, adapted or transmitted
in any form or by any means without the written permission of Agfa
HealthCare N.V.
4 | CR 10-X, CR 12-X, CR 15-X | Legal Notice
2491E EN 20150409 1543

Introduction
Topics:
•Introduction to this Manual
•Introduction to CR 10-X, CR 12-X and CR 15-X
CR 10-X, CR 12-X, CR 15-X | Introduction | 5
2491E EN 20150409 1543

Introduction to this Manual
Topics:
•Scope
•About the safety notices in this document
•Disclaimer
6 | CR 10-X, CR 12-X, CR 15-X | Introduction
2491E EN 20150409 1543

Scope
This manual contains information for safe and effective operation of the
CR 10-XTM, CR 12-XTM and CR 15-XTM digitizers, further referred to as the
digitizer, unless the information applies to a specific type.
CR 10-X, CR 12-X, CR 15-X | Introduction | 7
2491E EN 20150409 1543

About the safety notices in this document
The following samples show how warnings, cautions, instructions and notes
appear in this document. The text explains their intended use.
DANGER:
A danger safety notice indicates a hazardous situation of direct,
immediate danger for a potential serious injury to a user,
engineer, patient or any other person.
WARNING:
A warning safety notice indicates a hazardous situation which
can lead to a potential serious injury to a user, engineer, patient
or any other person.
CAUTION:
A caution safety notice indicates a hazardous situation which
can lead to a potential minor injury to a user, engineer, patient
or any other person.
An instruction is a direction which, if it is not followed, can
cause damage to the equipment described in this manual or any
other equipment or goods and can cause environmental
pollution.
A prohibition is a direction which, if it is not followed, can cause
damage to the equipment described in this manual or any other
equipment or goods and can cause environmental pollution.
Note: Notes provide advice and highlight unusual points. A note is
not intended as an instruction.
Safety icons
The purpose of safety icons is to indicate at a glance the type of caution,
warning or danger.
8 | CR 10-X, CR 12-X, CR 15-X | Introduction
2491E EN 20150409 1543

Disclaimer
Agfa assumes no liability for use of this document if any unauthorized changes
to the content or format have been made.
Every care has been taken to ensure the accuracy of the information in this
document. However, Agfa assumes no responsibility or liability for errors,
inaccuracies or omissions that may appear in this document. To improve
reliability, function or design Agfa reserves the right to change the product
without further notice. This manual is provided without warranty of any kind,
implied or expressed, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose.
Caution: In the United States, Federal law restricts this device to
sale by or on the order of a physician.
Introduction to CR 10-X, CR 12-X and CR 15-X
Topics:
•Intended Use
•Indications for Use
•Intended User
•Configuration
•Operation Controls
•System Documentation
•Training
•Product Complaints
•Compatibility
•Compliance
•Connectivity
•Installation
•Labels
•Cleaning and Disinfection
•Patient data security
•Maintenance
•Recurrent safety tests
•Environmental protection
•Safety Directions
•Quality Control
CR 10-X, CR 12-X, CR 15-X | Introduction | 9
2491E EN 20150409 1543

Intended Use
The digitizer is part of a CR system, further containing a cassette, image plate
and modality workstation. The CR system is used in a radiological
environment by qualified staff to read-out, process and route static X-ray
radiographic images.
The cassette is used to protect the image plate from light and damages during
X-ray exposure, transport and handling.
The image plate is used to capture the static X-ray radiographic images; the
image plate is scanned by the digitizer.
The digitizer is used to scan an X-ray exposed image plate; it results into a
digital image which is sent to the dedicated workstation.
The modality workstation is used to process and route the digital images from
the digitizer.
10 | CR 10-X, CR 12-X, CR 15-X | Introduction
2491E EN 20150409 1543
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere AGFA Messgerät Handbücher

AGFA
AGFA CR 30-X Bedienungsanleitung

AGFA
AGFA ADC Compact Plus Bedienungsanleitung

AGFA
AGFA CR 30-X Bedienungsanleitung

AGFA
AGFA 5522/100 Bedienungsanleitung

AGFA
AGFA 4406/027 Bedienungsanleitung

AGFA
AGFA ADC Solo Bedienungsanleitung

AGFA
AGFA PCR II Plus Bedienungsanleitung

AGFA
AGFA CR 85-X Bedienungsanleitung

AGFA
AGFA 5145 Leitfaden

AGFA
AGFA DX-G Bedienungsanleitung