1 Presentation of the equipment
1.1 Packaging
• 1 box: Outdoor unit.
• 1 box: Hydraulic module with NOx low burner and
outdoor temperature probe.
Pairing table
1.4 Denitions
- Split: the heat pump is composed of two parts (an
outdoor unit to be located outdoors and a Hydraulic
module to be installed inside the home).
- Air/water: the outdoor air is the energy source .
This energy is transmitted to the heating water by the
heat pump.
- Inverter: the fan and compressor speeds are modulated
to suit the heat requirements. This technology
economises energy and permits operation with single
phase power supply, regardless of the power rating
of the heat pump, by avoiding high current demands
when started.
- COP (coefcient of performance: this is the ratio
between the energy transferred to the heating circuit
and the electrical energy consumed.
- hybrid: the Hydraulic module operates with dual energy
(air/water heat pump and integrated oil boiler).
- low NOx: Burner designed to minimise the emission
of Nitrogen oxides NOx in the fumes. Generally low
NOx burners are considered to be burners whose
emission rate is below the most severe regulations at
that time. This limit chnages regularly according to the
regulations and technical progress.
Denomination : alféa hybrid duo oil low NOx ue model 11 14 + 11 3 ph. 14 3 ph. 16 3 ph.
Nominal heating performances (Outdoor T° / initial T°) - Heating power
+7 °C/+35°C - under-oor heating kW 10.30 13.50 10.60 13.25 14.89
-7 °C/+35°C - under-oor heating kW 10.10 11.22 9.75 13.00 13.50
+7 °C/+45°C - LT radiators kW 9.05 11.32 10.10 12.60 13.00
-7 °C/+45°C - LT radiators kW 8.33 10.41 8.66 12.50 13.00
Nominal heating performances (Outdoor T° / initial T°) - Absorbed power
+7 °C/+35°C - under-oor heating kW 2.57 3.50 2.68 3.20 3.70
-7 °C/+35°C - under-oor heating kW 3.94 4.68 3.69 5.18 5.40
+7 °C/+45°C - LT radiators kW 2.82 3.69 3.01 3.81 4.00
-7 °C/+45°C - LT radiators kW 4.05 5.24 4.04 6.00 6.37
Coefcient of performance (COP) (+7 °C / + 35 °C) 4.00 3.86 3.95 4.14 4.02
1.2 Optional equipment
• 2nd circuit kit (ref. 073953).
- to connect 2 heating circuits.
• Ambient probe T55 (ref. 073951) or
Ambient probe radio T58 (ref. 075313).
- to correct the ambient temperature.
• Central ambient unit T75 (ref. 073954) or
Central radio ambient unit T78 (ref. 074061).
- to correct the ambient temperature
and programme the PAC.
• Anti-vibration pins (ref. 523574).
• Floor support in white PVC (ref. 809532).
• Duo pool kit (ref. 074064).
• High ow circulator kit (ref. 073959).
- for a 1 circuit heated oor installation
with a PAC model 13 and 16.
1.3 Scope
This heat pump permits:
- heating in winter,
- the production of sanitary hot water,
- controlling two heating circuits *,
- heating the pool*.
*: These options require the use of additional kits
(see § "optional equipment").
1.5 General characteristics
Installation and operating manual "1605 - EN"
alfea hybrid duo heat pump oil low NOx CH
- 4 -
Heat pump Outdoor unit Hybrid duo hydraulic module
Model ref. export ref. Code ref. Code
alféa hybrid duo 11 single phase 522 694 WOYG112LCT 700117
MH-HD 024208
alféa hybrid duo 14 + single phase 522 695 WOYG140LCT 700142
alféa hybrid duo 11 three phase 522 696 WOYK112LCT 700118
alféa hybrid duo 14 three phase 522 697 WOYK140LCT 700143