Autoglide CABRI-30P Bedienungsanleitung

INSTRUCTIONS CABRI-30P/35P
Page1
SWING GATE OPENER

INSTRUCTIONS CABRI-30P/35P
Page2
SWING GATE OPENER
INDEX
Warnings 3. Control Box
1. Product Description and Application 4. Settings
1.1 Applications 4.1 Sw1 Dip Switch Setting
1.2 Description of the Automation. 4.1.1 Slowing Down Adjustment
1.3 Description of Devices 4.1.2 Over-Current Adjustment
1.3.1 CABRI-30P/35P Electromechanical
Gear Motors 4.1.3 Gate Auto Close Adjustment
1.3.2 Control Box 4.1.4 Pedestrian Mode Adjustment
1.3.3 Photocells 4.1.5 Flashing Light Adjustment
1.3.4 Radio Transmitter 4.2 Sw2 Dip Switch Setting
1.3.5 Flashing Light 4.2.1 Photocell Adjustment
1.3.6 Electric Latch with Stopper 4.2.2 Close delay of Dual Gate
Operation Adjustment
2. Installation
4.2.3 Electric latch Adjustment
2.1 Notes of Motors in Operation 4.2.4 Deceleration Speed Adjustment
2.1.1 Tools In Installing 4.2.5 Operation Speed Adjustment.
2.1.2 Motors, Components and its
Installation in Illustration 4.2.6 Single and Dual Gate Adjustment.
2.2 Power connection 4.3 LED Indication
2.2.1 Notes for Power Connection 4.4 Transmitter Memorizing Process
2.3 Installation 4.5 System Learning Process.
2.3.1 Preparation for Motor Installation 4.6 Gate Operation.
2.3.2 Installation of the Gear Motors 4.7 Gate Moving Logic.
2.3.3 Flashing Light 4.8 Advanced Operation of the
Transmitter.
2.3.4 Photocells 5. Trouble Shooting.
2.3.5 Electric Latch and Stopper 6. Technical Characteristics.

INSTRUCTIONS CABRI-30P/35P
Page3
SWING GATE OPENER
Warnings
Please read this instruction manual carefully before the installation of gate-automated
system.
This manual is exclusively for qualified installation personnel.
Autoglide
is not
responsible for improper installation and failure to comply with local electrical and
building regulations.
Keep all the components of CABRI-30P/35P system and this manual for further
consultation
•
Be aware of the hazards that may exist in the procedures of installation and
operation of the gate-automated system. Besides, the installation must be
carried out
in conformity with local standards and regulations
•
If the system is correctly installed and used following all the standards and
regulations, it will ensure a high degree of safety
•
Make sure that the gates works properly before installing the gate-
automated system and confirm the gates are appropriate for the
application.
•Do not let children operate or play with the gate-automated
system.
•Do not cross the path of the gate-automated system when operating.
•Please keep all the control devices and any other pulse generator away from
children to avoid the gate-automated system being activated accidentally.
•Do not make any modifications to any components except that it is
mentioned in this manual.
•Do not try to manually open or close the gates before you release the gear
motor.
•If there is a failure that cannot be solved and is not mentioned in this
manual, please contact qualified installation personnel.
•Do not use the gate-automated system before all the procedures and
instructions have been carried out and thoroughly read.
•
Test the gate-automated system weekly and have qualified installation
personnel to check and maintain the system at least every 6-month.
•
Install warning signs (if necessary) on the both sides of the gate to warn the
people in the area of potential hazards.

INSTRUCTIONS CABRI-30P/35P
Page4
SWING GATE OPENER
1. Product Description and Applications
1.1 Applications
CABRI-30P/35P is applied for residential automation of single or dual leaf gate.
CABRI-30P/35P has to be operated with electricity and it’s forbidden to be operated
by back-up batteries for normal use. Back-up batteries are only allowed for emergent
operation when there is a power failure, and the gear motors can be released by
special keys to move the gate manually.
1.2 Description of theAutomation
The following diagram of CABRI-30P typical installation describes some
terms and accessories of a gate automation system
Figure 1
1.3 Description of devices
CABRI-30P/35P
includes the accessories shown in figure 2. Please check the
accessories the same as the package provided.
Attn: some accessories not included due to customization
•
2 CABRI-30P/35P electromechanical gear motors with mounting brackets
•
1 pair of photocells.(one TX and one RX)
Figure 2
•
2 Radio transmitters, Flashing Light, Control Box, Electric Latch and Stopper

INSTRUCTIONS CABRI-30P/35P
Page5
SWING GATE OPENER
1.3.1 CABRI-30P/35P Electromechanical Gear Motors
CABRI-30P/35P
consists of a worm screw reduction gear and a 24V DC motor.
The gear motor could be released manually by special release keys when there is a
power failure.
The gear motor is installed with two post brackets, one rear plate and one front plate
for the installation
. Figure 3
LIST OF SMALL PARTS CABRI-30P/35P
Front Plate 2pcs M8 self-locking nut 4pcs
Rear Plate 2pcs M12*25L hex bolt 2pcs
Post bracket 4pcs M12 self-locking nut 2pcs
M8 *25L hex bolt 4pcs Release key 2pcs
1.3.2 Control Box
Control box consists of one control panel with incorporated receiver and one
transformer. Provides the complete automation of the gear motors and other
accessories of CABRI-30P/35P kit. To connect separate terminals on the control panel
and activate the gear motors and other accessories, the installation manual has to be
carefully read before handling.
Figure 4
LIST OF SMALL PARTS CABRI-30P/35P
5*30 Screw 4pcs
Nylon screw anchor 4pcs

INSTRUCTIONS CABRI-30P/35P
Page6
SWING GATE OPENER
1.3.3 Photocells
The pair of Photocells has to be installed on the wall and connected to the control
panel. The function of the photocells is to detect the obstacles found on the optical
axis between the transmitter (TX) and the receiver (RX).
Figure 5
1.3.4 Radio Transmitter
Radio transmitter is used for the remote control of the gate movement. To use the
transmitter, press and hold the button for 1 second. There are two buttons on the
transmitter and (A) button is “open-stop-close mode” and (B) button is “pedestrian
mode”.
1.3.5 Flashing Light
Flashing light is controlled by control box andblinks when the gate is moving.
The flashing light stops blinking when the gates finish opening or closing
Figure 7

INSTRUCTIONS CABRI-30P/35P
Page7
SWING GATE OPENER
1.3.6 Electric Latch and Stopper
Electric latch is used to lock the gate and it has to be used with stopper and installed
on the master gate.
Figure 8
LIST OF SMALL PARTS
M8*25L hex bolt 3pcs
M8 self locking nut 3pcs
Key
2pcs
2) Installation:
2.1 Notes of Motors in Operation
The CABRI-30P/35P gate openers are applicable to per leaf of 3.5/4 meters in width
and 300/350 kg in weight which can be opened up to 110 degrees primarily for
residential use; where the performance shall be influenced by the factors such as gate
dimension, weight and climate that the driven torque is necessarily to be adjusted
properly
.
2.1.1 Tools in Installing
Please make sure all tools and cables are ready and conform to the industrial
safety standard before installation. Please refer to Figure 9.
Figure 9

INSTRUCTIONS CABRI-30P/35P
Page8
SWING GATE OPENER
2.1.2 Motors, Components and Its Installation in Illustration
The installation procedure of CABRI-30P/35P may be changed due to Various
accessories and quantities installed. The basic wiring diagram is shown in Figure 10.
No wiring cables for accessories are supplied with CABRI-30P/35P.
Figure 10
2.2 Power Connection
CABRI-30P/35P is required to connect two cores wires, which requires very low
voltage that no professionally trained personnel is required in installation; however, the
users are advised to read the installation manual carefully before going for it. After
getting to know all accessories and their positions, suggest starting from cable conduit
arrangement to prevent the cables from being broken or damaged.
2.2.1 Notes for Power Connection
1. The installation of power supply cable to the motor should be carried out
by a qualified professional electrician.
2. The power supply cable of the motor should be equipped with short circuit
protection and leakage protection.
3.
Please make sure to shut off the power before going installation or maintenance
.
2.3 Installation
2.3.1 Preparation for Motor Installation
CABRI-30P/35P is not applicable to a gate which is inefficient or unsafe, neither to
solve the defects due to incorrect installation nor poor maintenance.

INSTRUCTIONS CABRI-30P/35P
Page9
SWING GATE OPENER
1)
Make sure the weight and dimensions of the gate conform to the operation range of
CABRI-30P/35P. Don’t use CABRI-30P/35P if the specifications do not meet the
requirements.
2). Make sure the gate structure conform to the criteria of automatic operation and
force regulations.
3). Make sure there is no serious friction existing in the opening or closing travel of the
gate leaves.
4). Make sure the gate is at horizontal level that the gate will not move aside at any
position.
5). Make sure the gate can bear the impact of the motor torque when it is installed on
any hole of the bracket which the surface is sufficiently sturdy.
6). Make sure the photo sensors are installed on flat surfaces to ensure the two ends of
receiving and transmitting corresponded to each other.
7). Check the dimensions of the motors as below.
Figure 11
8). Make sure to leave enough space when the gate is opening
Figure 12(Aerial View)

INSTRUCTIONS CABRI-30P/35P
Page10
SWING GATE OPENER
9).
If the gate is OPENED OUTWARD, please leave at least 70mm between the post
brackets and the gate.
Figure 13 (Aerial View)
Figure 14 (Aerial View)
10) Using the leaf-opening angle as criteria to make sure all criteria in Figure 15
can be met.
Figure 15
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Autoglide Toröffner Handbücher

Autoglide
Autoglide FERO 600-M Bedienungsanleitung

Autoglide
Autoglide VELOCE 80A Bedienungsanleitung

Autoglide
Autoglide CASA-120-O Bedienungsanleitung

Autoglide
Autoglide MAGRO-35A Bedienungsanleitung

Autoglide
Autoglide CASA-50P Bedienungsanleitung

Autoglide
Autoglide CABRI-20P Bedienungsanleitung

Autoglide
Autoglide Magro-500 J Bedienungsanleitung