Axio MET AX-355 Bedienungsanleitung

AC/DC TRUE RMS CLAMP METER
AX-355
INSTRUCTION MANUAL

2
CONTENTS
1. Measuring Limits ................................................................................................ 3
2. Safety Information .............................................................................................. 3
3. Features .......................................................................................................... 5
4. Instrument Layout .............................................................................................. 6
5. S ecifications .................................................................................................... 6
6. DC Current Measurement ...................................................................................... 9
7. AC Current Measurement ..................................................................................... 10
8. DC Voltage Measurement ..................................................................................... 11
9. AC Voltage Measurement ..................................................................................... 12
10. Resistance Measurement .................................................................................... 13
11. Ca acitance Measurement ................................................................................. 14
12. Frequency Measurement .................................................................................... 15
13. tem erature Measurement ................................................................................. 16
14. Diode Test ..................................................................................................... 16
15. Continuity testing ............................................................................................ 17
16. Data Hold Functions ......................................................................................... 18
17. Peak Hold Functions ......................................................................................... 18
18. LCD Backlight ................................................................................................. 19
19. Auto Power Off ............................................................................................... 19
20. Battery Re lacement ........................................................................................ 19

3
1. Measuring Limi s
DC Am erem: 0.01A to 1000A
AC Am erem: 0.01A to 1000A
DC Voltage: 0.1mV to 600V
AC Voltage: 0.1mV to 600V
Resistance: 0,1Ω to 400MΩ
Ca acitance: 0.001nF to40mF
Frequency: 0.001 kHz to 4kHz
Tem erature: -40°C to 1000°C
-40 °F to 1832 °F
2. Safe y Informa ion
His manual contains information that must be followed for o erating the meter safely and
maintaining the meter in a safe o erating condition. If the meter is not used in a manner s ecified
in this manual, the rotection rovided by the meter may be im aired.
The Model has been designed and com lies with IEC 61010-1 and EN 61010-1. Safety requirements
for Electronic measuring A aratus.
WARNING
•Read through the o erating instructions thoroughly and understand the instruction before
o erating the meter.
•Kee the manual at hand so as to enable quick reference when necessary.
•Ensure that the use of the meter is in its intended a lications and follow measurement
rocedures described in this manual.
•Follow all safety and o erating instructions to ensure maximum ersonal safety during the use and
o eration to the meter.
•Fallure to follow the above instructions may cause injury, instrument damage and/or damage to
equi ment under test.
•The symbol indicated on the meter means that the user must refer to related arts in the manual
for safe o eration of the meter. Be sure to carefully read the instructions following each symbol in
this manual.

4
DANGER is reserved for conditions and actions that are likely to cause serious or
fatal injury.
WARNING is reserved for conditions and actions that are likely to cause serious
or fatal injury.
CAUTION is reserved for conditions and actions that are likely to cause minor
injury.
DANGER :
•Never use the meter to measure voltages on a circuit above the maximum allowable in ut value
on any function.
•Do not exceed the maximum allowable in ut of any measurement range.
•Never touch ex osed wiring connections or any live circuit when attem ting to take
measurements.
•Do not attem t to make measurements in flammable gaseous areas, fumes, va or or dust. The use
of the instrument in these areas may cause s arking, which can lead to an ex losion.
•Do not attem t to use the instrument if its surface or your hand is wet.
•Never o en the battery com artment cover when making measurements.
WARNING:
•Always ins ect the meter and test Leeds for any signs of damage or abnormality before use. If the
meter or its accessories have any structural defects such as broken test leads, cracked cases,
ex osed metal arts or the dis lay is not reading do not attem t to make measurements.
•Do not turn the function switch whilst test leads are connected to the meter.
•Do not install substitute arts or make modifications to the meter. Return the meter to your
distributor for re air or re-calibration.
•Ensure the meter is switch off before o ening the battery cover when re lacing the battery.
•Never re lace a battery in the surface of the meter is wet or moist.

5
CAUTION:
•Before making measurements ensure that the function selector switch is set on the a ro riate
range osition
•Always make sure that the lug of each test lead is inserted fully into the a ro riate terminal of
the meter.
•Ensure that the function selector switch is set to the “OFF” osition after use. When the meter
will not be in use for a long eriod of time, lace it in storage after removing the battery.
•Do not ex ose the meter to direct sunlight, extreme tem eratures or moisture.
•Do not use abrasives or solvents on the meter. To clean it use a dam cloth and mild detergent
only.
Qualified and trained service technicians should only erform calibrations and re air of the meter.
3. FEATURES
•True RMS measurement of AC Current and AC Voltage
•Large 4000 count LCD dis lay with a bargra h and a bright white LED backlight.
•Wide measuring range from 0,01A AC/DC u to 1000A AC/DC
•Measures AC and DC Voltage u to 600 volts.
•Measures resistance from 0,01Ω u to 40MΩ
•Ca acitance measurements u to 40mF
•Tem erature measurement from -40°C to +1000°C and -40 °F to +1832°F
•Designed to the international safety standard IEC61010 CAT III 600V/CAT III 1000V.
Pollution degree: 2
•Auto Power Off after a roximately 20 minutes to conserve battery life.
•Continuity Buzzer and Diode Test
•Frequency measurement u to 4kHz.
•Peak Hold to record the minimum and maximum readings for current and voltage.
•Data Hold switch used to freezer reading on dis lay.

6
4. INSTRUMENT LAYOUT
5. SPECIFICATION
Clam Size 30cm o ening a rox.
Diode Test: Test Current of 0.3mA ty ical
O en circuit voltage 1.5V DC
Continuity Check: Threshold < 35Ω, Test current < 1mA
Low Battery Indication: is dis layed
Over range Indication: “OL” is dis layed
Measurements Rate 2 er second, normal
In ut Im edance: 10MΩ (VDC and VAD)
Dis lay: 4000 count LCD
AC Current: 50/60Hz(ACC)

7
AC Voltage Bandwidth: 50/60Hz(VAC)
O erating Tem erature: -10°C to 50°C (14°F to 122°F)
Storage Tem erature: -30°C to 60°C ( -22°F to 140°F)
Relative Humidity: U to 85%
Over Voltage: Category III 600V
Battery: One DC 9V IEC6F22 1604 Battery
Auto Power OFF: A rox.20 minutes
Dimensions: 229x60x49 mm
Weight: 100g
DC Curren :
Range Measuring Range Resolution Accuracy(% of Reading)
40A 0 ~ 40.00A 0.01A ±(2.0% + 10 cyfr)
400A 0 ~ 400.0A 0.1A ±(2.8% + 8 cyfr)
1000A 0 ~ 1000A 1A ±(3.0% + 8 cyfr)
AC Curren :
Range Measuring Range Resolution Accuracy(% of Reading)
40A 0 ~ 40.00A 0.01A ±(2.0% + 10 cyfr)
400A 0 ~ 400.0A 0.1A ±(2.8% + 8 cyfr)
1000A 0 ~ 1000A 1A ±(3.0% + 8 cyfr)
DC Vol age:
Range Measuring Range Resolution Accuracy(% of Reading)
400mV 0 ~ 400.00mV 0.1mV ±(1.0% + 10 cyfr)
4V 0 ~ 4.000V 0.001V ±(1.5% + 8 cyfr)
40V 0 ~ 40.00V 0.01V
400V 0 ~ 400.0V 0.1V
600V 0 ~ 600V 1V ±(2.0% + 8 cyfr)

8
AC Vol age:
Range Measuring Range Resolution Accuracy(% of Reading)
400mV 0 ~ 400.0mV 0.1mV ±(1.0% + 10 cyfr)
4V 0 ~ 4.000V 0.001V ±(1.5% + 8 cyfr)
40V 0 ~ 40.00V 0.01V
400V 0 ~ 400.0V 0.1V
600V 0 ~ 600V 1V ±(2.0% + 8 cyfr)
Note: No Automating on 400mV AC Range
Resis ance:
Range Measuring Range Resolution Accuracy(% of Reading)
400Ω 0 ~ 400.0Ω 0.1Ω ±(1.0% + 4 cyfry)
4kΩ 0 ~ 4.000kΩ 1Ω ±(1.5% + 2 cyfry)
40kΩ 0 ~ 40.00kΩ 10Ω
400kΩ 0 ~ 400.0kΩ 100Ω
4MΩ 0 ~ 4.000MΩ 1kΩ ±(2.5% + 5 cyfr)
40MΩ 0 ~ 40.00MΩ 10kΩ ±(3.5% + 10 cyfr)
Capaci ance:
Range Measuring Range Resolution Accuracy(%of Reading)
4nF 0 ~ 4.000nF 0.001nF ±(5.0% + 30 cyfr)
40nF 0 ~ 40.00nF 0.01nF ±(5.0% + 20 cyfr)
400nF 0 ~ 400.0nF 0.1nF ±(3.0% + 5 cyfr)
4µF 0 ~ 4.000µF 0.001µF
40µF 0 ~ 40.00µF 0.01µF
400µF 0 ~ 400.0µF 0.1µF ±(4.0% + 10 cyfr)
4mF 0 ~ 4.000mF 0.001mF ±(4.5% + 10 cyfr)
40mF 0 ~ 40.00mF 0.01mF ±(5.0% + 10 cyfr)

9
Frequancy:
Range Measuring Range Resolution Accuracy(% of Reading)
4kHz 0 ~ 4.000kHz 0.001kHz ±(1.5% + 2 cyfry)
Czułość: 5V rms min.
Tempera ure:
Range Measuring Range Resolution Accuracy(% of Reading)
°C -40°C ~ 1000°C 1°C ±(2.5% + 3°C)
°F -40°F ~ 1832°F 1°F ±(2.5% + 5°F)
6. DC CURRENT MEASUREMENT
WARNING: Ensure that the test Leeds are disconnected from the meter before making
current measurements.
1. Set the function switch to or or range osition, and make sure that the
current under test does not exceed the u er limit of the measuring range you hale selected.
The meter automatically defaults to DC Current.
2. Press the button once the sign will a ear on the LCD indicating Rang is zero.
3. Press the trigger to o en u the transformer jaws and clam around the single conductor under
test.
4. Read the dis lay.
No e:
•During current measurements kee the transformer jaws fully closed, otherwise this affect the
accuracy of the measurement.
•When large current the transformer jaws may buzz. This is not a fault and does not affect the
accuracy of the reading.

10
7. AC TRUE RMS CURRENT MEASUREMENT
WARNING: Ensure that the test leads are disconnected from the meter before making
current measurements.
1. Set the function switch to or or range osition, and make sure that the
current under test does not exceed the u er limit of the measuring range you hale selected.
2. Press the button to select the AC Current range. The meter automatically defaults to DC
Current.
3. Press the trigger to o en u the transformer jaws and clam around the single conductor under
test.
4. Read the dis lay.
No e:
•During current measurements kee the transformer jaws fully closed, otherwise this will affect
the accuracy of the measurement.
•When large currents the transformer jaws may buzz. This is not a fault and does not affect the
accuracy of default to “Auto Range” mode.
•The meter is set hold button will allow the user to record the eak maximum and
minimum Reading on the AC volt range. See age 19 for further instructions for “PEAK” Hold
function.
Inhaltsverzeichnis
Andere Axio MET Messgerät Handbücher

Axio MET
Axio MET AX-C800 Bedienungsanleitung

Axio MET
Axio MET AX-202 Bedienungsanleitung

Axio MET
Axio MET AX-5001 Bedienungsanleitung

Axio MET
Axio MET AX-AN050 Bedienungsanleitung

Axio MET
Axio MET AX-3550 Bedienungsanleitung

Axio MET
Axio MET AX-7250 Bedienungsanleitung

Axio MET
Axio MET AX-2040 Bedienungsanleitung

Axio MET
Axio MET AX-572 Bedienungsanleitung

Axio MET
Axio MET AX-C705 Bedienungsanleitung

Axio MET
Axio MET AX-C850 Montageanleitung