Bürkert 8025 Series Bedienungsanleitung

Operating Instructions
Bedienungsanleitung
Manuel d‘utilisation
Type 8025
UNIVERSAL
Flow transmitter
Durchfluss-Transmitter
Transmetteur de débit

We reserve the right to make technical changes without notice.
Technische Änderungen vorbehalten.
Sous réserve de modifications techniques.
© Bürkert SAS, 2012 - 2017
Operating Instructions 1710/03_EU-ML 00555851 / Original FR

3
1 ABOUT THE OPERATING INSTRUCTIONS ..........................................................................................................................6
1.1 Symbols used .........................................................................................................................................................................6
1.2 Definition of the word "device" .......................................................................................................................................6
2 INTENDED USE ...................................................................................................................................................................................7
3 BASIC SAFETY INFORMATION ..................................................................................................................................................8
4 GENERAL INFORMATION ................................................................................................................................................................9
4.1 Manufacturer's address and international contacts ............................................................................................9
4.2 Warranty conditions ..............................................................................................................................................................9
4.3 Information on the Internet ...............................................................................................................................................9
5 DESCRIPTION ....................................................................................................................................................................................10
5.1 General description ...........................................................................................................................................................10
5.2 Description of the rating plate ....................................................................................................................................10
6 TECHNICAL DATA ...........................................................................................................................................................................11
6.1 Conditions of use ..............................................................................................................................................................11
6.2 Conformity to standards and directives ................................................................................................................11
6.2.1 UL certification ...................................................................................................................................11
6.3 Mechanical data .................................................................................................................................................................11
6.4 Dimensions ...........................................................................................................................................................................12
6.5 Electrical data ......................................................................................................................................................................12
6.6 Specifications of the connected flow sensor .....................................................................................................13
7 INSTALLATION AND WIRING ....................................................................................................................................................14
7.1 Safety instructions ............................................................................................................................................................14
7.2 Installation of a panel version .....................................................................................................................................15
7.3 Installation of a wall-mounted version ...................................................................................................................16
7.4 Wiring .......................................................................................................................................................................................17
7.4.1 Specifications of the connection cables ......................................................................................18
7.4.2 Equipotentiality of the installation ..................................................................................................18
7.4.3 Terminal assignment and use of the selectors ...........................................................................20
7.4.4 Wiring a panel version .....................................................................................................................22
7.4.5 Wiring a wall-mounted version ......................................................................................................22
English
Type 8025 UNIVERSAL

4
7.4.6 Wiring the AO1 current output of a panel version or a wall-mounted version,
12...36 V DC ......................................................................................................................................23
7.4.7 Wiring the digital output DO1 (transistor) of a panel version or a wall-mounted
version, 12...36 V DC .......................................................................................................................24
7.4.8 Wiring the AO1 current output of a wall-mounted version, 115/230 V AC .......................25
7.4.9 Wiring the digital output DO1 (transistor) of a wall-mounted version, 115/230 V AC ....27
7.4.10 Wiring the digital outputs DO2 and DO3 (relays) of a panel or a wall-mounted version 28
7.4.11 Connecting the flow sensor to the transmitter ...........................................................................29
8 OPERATING AND COMMISSIONING ....................................................................................................................................32
8.1 Safety instructions .............................................................................................................................................................32
8.2 Operating levels of the device ....................................................................................................................................32
8.3 Description of the navigation keys and the status LEDs .............................................................................35
8.4 Using the navigation keys ............................................................................................................................................36
8.5 Details of the Process level .........................................................................................................................................37
8.6 Details of the Parameters menu ...............................................................................................................................37
8.6.1 Choosing the display language .....................................................................................................38
8.6.2 Choosing the flow rate units, the number of decimals and the units of the totalizers ......39
8.6.3 Entering the K factor of the fitting used .......................................................................................41
8.6.4 Determining the fitting K factor using a Teach-In procedure ...................................................41
8.6.5 Configuring the outputs (general diagram) .................................................................................44
8.6.6 Associating a flow rate range to the current output AO1 ........................................................44
8.6.7 Activating / Deactivating the emission of a 22 mA current on the current output .............45
8.6.8 Configuring the transistor output DO1 as a pulse output proportional to a volume .........46
8.6.9 Configuring the transistor output DO1 to transmit the rotational frequency of
the paddle wheel ...............................................................................................................................46
8.6.10 Configuring the transistor output DO1 to switch a load depending on two
threshold values .................................................................................................................................47
8.6.11 Configuring the transistor output DO1 to switch a load when a warning mes-
sage is generated by the device ....................................................................................................49
8.6.12 Configuring the relay outputs DO2 and DO3 to switch a load depending on
two thresholds ...................................................................................................................................50
8.6.13 Configuring the relay outputs DO2 and DO3 to switch a load when a warning
message is generated by the device ............................................................................................51
8.6.14 Configuring the filter of the measured flow rate .........................................................................51
8.6.15 Resetting both totalizers ...................................................................................................................53
8.6.16 Parameterizing the cut-off flow rate ..............................................................................................53
8.6.17 Setting the brightness of the display and how long it stays ON, or deactivating
the backlight .......................................................................................................................................54
English
Type 8025 UNIVERSAL

5
8.7 Details of the Test menu ...............................................................................................................................................55
8.7.1 Adjusting the current output ...........................................................................................................56
8.7.2 Reading the rotational frequency of the paddle wheel .............................................................57
8.7.3 Checking the outputs behaviour ....................................................................................................57
8.7.4 Monitoring the flow rate in the pipe ..............................................................................................57
8.7.5 Monitoring the value of the daily totalizer ......................................................................................59
8.8 Details of the Information menu .................................................................................................................................59
9 MAINTENANCE AND TROUBLESHOOTING .....................................................................................................................60
9.1 Safety instructions ............................................................................................................................................................60
9.2 Cleaning the device ..........................................................................................................................................................60
9.3 If you encounter problems ...........................................................................................................................................60
9.3.1 Resolution of problems when the device status LED is OFF .................................................60
9.3.2 Resolution of problems without message generation and device status LED is red ........61
9.3.3 Resolution of problems without message generation and device status LED is orange . 62
9.3.4 Resolution of problems without message generation but device status LED is ON ........63
9.3.5 Resolution of problems without message generation and device status LED is green ...64
9.3.6 Resolution of problems linked to warning messages not registered in the Infor-
mation menu .......................................................................................................................................65
10 SPARE PARTS AND ACCESSORIES ....................................................................................................................................66
11 PACKAGING, TRANSPORT ........................................................................................................................................................66
12 STORAGE ............................................................................................................................................................................................66
13 DISPOSAL OF THE DEVICE ......................................................................................................................................................67
English
Type 8025 UNIVERSAL

6
About the Operating Instructions
1 ABOUT THE OPERATING INSTRUCTIONS
The Operating Instructions describe the entire life cycle of the device. Please keep the Operating Instructions in a
safe place, accessible to all users and any new owners.
The Operating Instructions contain important safety information.
Failure to comply with these instructions can lead to hazardous situations. Pay attention in particular to the
chapters "3 Basic safety information" and "2 Intended use".
▶Whatever the version of the device, the Operating Instructions must be read and understood.
1.1 Symbols used
DANGER
Warns against an imminent danger.
▶Failure to observe this warning results in death or in serious injury.
WARNING
Warns against a potentially dangerous situation.
▶Failure to observe this warning can result in serious injury or even death.
CAUTION
Warns against a possible risk.
▶Failure to observe this warning can result in substantial or minor injuries.
NOTICE
Warns against material damage.
Indicates additional information, advice or important recommendations.
Refers to information contained in these Operating Instructions or in other documents.
▶Indicates an instruction to be carried out to avoid a danger, a warning or a possible risk.
→Indicates a procedure to be carried out.
1.2 Definition of the word "device"
The word "device" used within these Operating Instructions refers to the transmitter type 8025 Universal with
serial numbers higher or equal to 20 000.
English
Type 8025 UNIVERSAL

7
Intended use
2 INTENDED USE
Use of the device that does not comply with the instructions could present risks to people, nearby
installations and the environment.
The transmitter 8025 Universal has been designed to process a frequency signal, received from a flow sensor
connected to the transmitter.
▶Use the device in compliance with the characteristics and commissioning and use conditions specified in the
contractual documents and in the Operating Instructions.
▶Never use the transmitter 8025 Universal for security applications.
▶Use the device only in combination with foreign devices or foreign components recommended or approved by
Bürkert.
▶Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, the
effects of climatic conditions.
▶Only operate a device in perfect working order.
▶Store, transport, install and operate the device properly.
▶Only use the device as intended.
English
Type 8025 UNIVERSAL

8
Basic safety information
3 BASIC SAFETY INFORMATION
This safety information does not take into account any contingencies or occurrences that may arise during instal-
lation, use and maintenance of the device.
The operating company is responsible for the respect of the local safety regulations including for the staff safety.
Danger due to electrical voltage.
▶If a 12...36 V DC energized version is installed either in a wet environment or outdoors, all the electrical volt-
ages must be of max. 35 V DC.
▶Before carrying out work on the system, disconnect the electrical power for all the conductors and isolate it.
▶All equipment connected to the device must be double insulated with respect to the mains according to the
standard IEC 61010-1:2010.
▶Observe all applicable accident protection and safety regulations for electrical equipment.
Various dangerous situations
To avoid injury:
▶Do not use the device in explosive atmospheres.
▶Do not use the device in an environment incompatible with the materials it is made of.
▶Do not subject the device to mechanical stress.
▶Do not make any modifications to the device.
▶Prevent any unintentional power supply switch-on.
▶Only qualified and skilled staff can carry out the installation and maintenance work.
▶Guarantee a defined or controlled restarting of the process, after a power supply interruption.
▶Observe the general technical rules.
NOTICE
Elements / Components sensitive to electrostatic discharges
The device contains electronic components sensitive to electrostatic discharges. They may be damaged if they
are touched by an electrostatically charged person or object. In the worst case scenario, these components are
instantly destroyed or go out of order as soon as they are activated.
▶To minimise or even avoid all damage due to an electrostatic discharge, take all the precautions described in
standard EN 61340-5-1.
▶Also ensure that you do not touch any of the live electrical components.
English
Type 8025 UNIVERSAL

9
General information
4 GENERAL INFORMATION
4.1 Manufacturer's address and international contacts
To contact the manufacturer of the device, use following address:
Bürkert SAS
Rue du Giessen
BP 21
F-67220 TRIEMBACH-AU-VAL
You may also contact your local Bürkert sales office.
The addresses of our international sales offices are available on the internet at: www.burkert.com
4.2 Warranty conditions
The condition governing the legal warranty is the conforming use of the device in observance of the operating
conditions specified in these Operating Instructions.
4.3 Information on the Internet
You can find the Operating Instructions and technical data sheets regarding the type 8025 at: www.burkert.com
English
Type 8025 UNIVERSAL

10
Description
5 DESCRIPTION
5.1 General description
The 8025 Universal is a flow transmitter with display, available in wall-mounted and panel versions:
• The panel version is made up of an electronics integrated in an open housing with display.
• The wall-mounted version is made up of an electronics integrated in a housing with cover, display and 3 cable
glands.
The device is equipped with a 4...20 mA current output (analogue output, called AO1), a transistor output (con-
figured as a pulse output by default, called DO1) and two totalizers.
Some versions are also fitted with two relay outputs (called DO2 and DO3).
The device operates on a 3 wire system and needs a 12...36 V DC or a 115/230 V AC power supply.
The electrical connection is carried out on the terminal blocks of the electronic board.
5.2 Description of the rating plate
LFLOW 8025 PANEL SUPPLY: 12-36V= 210 mA
DO1: 5-36V= 100mA AO1:4-20mA
DO2&3: 2xRelay 30 and 42V peak or 60V... max. IP20
S/N 20 000
00564417 W46MA
Made in France
1
10
6
781112
35
9
4
2
1. Measured value
2. Type of the device, housing
3. Specifications of the digital output DO1
(transistor)
4. Specifications of the analogue output AO1
5. Supply voltage and max. current
consumption
6. Protection class of the device
7. Manufacturing code
8. Conformity markings
9. Warning: Before using the device, take into account the technical specifications described in these Oper-
ating Instructions.
10. Specifications of the relay outputs DO2 and DO3
11. Serial number
12. Order code
Figure 1: Rating plate of the device (example)
English
Type 8025 UNIVERSAL
Andere Handbücher für 8025 Series
18
Inhaltsverzeichnis
Andere Bürkert Sender Handbücher
Beliebte Sender Handbücher anderer Marken

Dejero
Dejero EnGo 3x Bedienungsanleitung

Rosemount
Rosemount 4600 Bedienungsanleitung

Speaka Professional
Speaka Professional 2342740 Bedienungsanleitung

trubomat
trubomat GAB 1000 Bedienungsanleitung

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Bedienungsanleitung

Rondish
Rondish UT-11 Bedienungsanleitung