Cellar Cool CM Bedienungsanleitung

CM SERIES
VERSION 2
OWNER’S MANUAL
NOTICE: To activate the split system warranty,
the installing certied HVAC/R service tech
must complete the split system warranty
checklist and send back to CellarCool.
24V Thermostat Conversion Kit Option

Copyright © 2012. CellarCool. All rights reserved.
CellarCool copyrights this manual, the product design, and the design concepts, with all rights reserved. Your rights with
regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the
USA. Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any printed
or electronic medium or to any machine-readable form, for any purpose, in whole or in part, without the written consent
of CellarCool.
Every effort has been made to ensure that the information in this manual is accurate. CellarCool is not responsible for
printing or clerical errors.
CellarCool reserves the right to make corrections or improvements to the information provided and to the related
hardware at any time, without notice.
Vinothèque and CellarCool are registered trademarks, and ECE is a trademark of CellarCool. All rights reserved.
Mention of third-party products is for informational purposes only and constitutes neither an endorsement nor a
recommendation. CellarCool assumes no liability with regard to the performance or use of these products.
01.04.2017
We manufacture, test and certify 100% of our wine cooling units in
the USA. By sourcing the best components and closely controlling our
manufacturing processes, we can assure the highest-quality,
lowest defect manufacturing rates in the industry.
Conforms to ANSI/UL Std 427
Certied to CAN/CSA Std C22.2 No. 120

TABLE OF CONTENTS
Introduction ................................................ 3
Before You Start ............................................ 4
Receiving & Inspecting the System ......................... 5
Quick Reference Guide
Knockout Locations ...................................... 7
Unit Specications ....................................... 8
Condensing Unit ......................................... 10
Preparing the Wine Cellar................................... 11
System Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting Guide ..................................... 16
Maintenance Schedule ..................................... 19
Technical Assistance & Accessories ......................... 20
Installation Terms and Conditions .......................... 21

CCM 062817
Page 2 | 1-855-235-5271
WARNING
The evaporator unit (fan coil unit) must be insulated using the insulation blanket provided in
accordance with this manual. Refer to the insulation blanket installation instructions.
Failure to follow the instructions provided will result in a poor vapor barrier, water
damage, rust, and system corrosion which will void the warranty on your unit.
The evaporator unit (fan coil unit) must be insulated using berglass insulation (R13 or higher)
in addition to the provided insulation blanket. This includes the cavity between the ceiling
joists. A warm attic environment will reduce the capacity of the cooling system, as the system
will absorb heat from the attic in addition to the heat load from the wine cellar. This, in eect,
will signicantly reduce the cooling system’s ability to cool the wine cellar.
Failure to properly insulate the evaporator unit may cause condensation to form on the
surface of the housing and water damage to the surrounding structure, the cooling unit, and
possibly the wine cellar.
To avoid these issues, install the insulation kit and insulate the surface of the evaporator unit
that is located outside of the wine cellar using berglass insulation.
*Additional insulation is required!

www.cellarcool.com | Page 3
CM SERIES
WARRANTY REGISTRATION
In order to activate the warranty of your system, the verication and operational
documentation must be completed by the certied refrigeration technician
installing your system and submitted via mail, fax, or e-mail.
Mail to:
CellarCool
ATTN: Warranty Registration
1738 E. Alpine Avenue
Stockton, CA 95205-2505
USA
Fax to:
209-466-4606
Scan and email to:
warranty@cellarcool.com
INTRODUCTION
Customer Service
Thank you for purchasing a CellarCool cooling system. We strive to provide the highest-quality products and the best possible
customer service. If you have any questions about your system, please call us at 1-855-235-5271 or visit cellarcool.com.
Using the Manual
This owner’s manual is intended to assist in the proper maintenance of the cooling system. In order to ensure the longevity of
your cooling unit, the equipment should be installed as outlined in the technician’s manual. It is also vital to establish a proper
care and maintenance schedule. Please read and review this manual carefully and keep it for future reference.
What is the CellarCool Cooling System?
The CellarCool cooling system is a specialized refrigeration system designed for one purpose only: to maintain the optimal
temperature and humidity levels conducive to the proper storage and aging of ne wines. This system produces minimal in-cellar
noise and has the most lenient exhaust requirements. An exterior housing is required for outdoor condensing unit installations.
How Does the Cooling System Work?
Similar to the air conditioning systems used for homes, the evaporator unit (fan coil unit) and condensing units are installed
in separate locations and are connected by a refrigerant line set. The evaporator portion is commonly installed in the wine
cellar, with the condensing unit is located either outside or in a remote indoor location that is ventilated. An exterior housing is
required for outdoor condensing unit installations.
Temperature Setting
The system is designed to maintain a cellar temperature of 55°F as long as the ambient temperature does not exceed 110°F.

CCM 062817
Page 4 | 1-855-235-5271
BEFORE YOU START
1-800-343-9463
1. Inspect all components prior to installation. If damage is found, please contact your distributor or CellarCool Customer
Service at 1-800-343-9463.
2. The evaporator unit and condensing unit each require a dedicated 115V, 20-amp circuit. Use a surge protector with the
unit. Do not use a GFI (ground fault interrupter) line.
3. The evaporator unit and condensing unit require no communication lines unless the system is equipped with a Cold Weather
Start Kit. If the system is equipped with a Cold Weather Start Kit, a low-voltage 18-2 thermostat wire will need to be run
between the evaporator unit (fan coil unit) and the condensing unit.
4. A standard 18-5 thermostat wire must be run from the evaporator unit (fan coil unit) to the thermostat.
5. You are REQUIRED to install a drain line to remove condensation from the evaporator unit (fan coil unit).
6. The warranty is not active until a warranty checklist has been received, reviewed, and approved.
7. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine storage
consultant with a valid contractor’s license to build your wine cellar.
8. CellarCool requires that all split systems be installed by a certified HVAC-R technician only. NATE or equivalent is
recommended.
If you encounter a problem with your CellarCool system, please refer to the Troubleshooting Guide. If you have any further
questions or concerns, or need assistance, please contact CellarCool’s Customer Service at 1-800-343-9463. Please be sure
all testing has been completed prior to contacting Customer Service. Please have your results ready for your representative.

www.cellarcool.com | Page 5
CM SERIES
RECEIVING & INSPECTING THE SYSTEM
• Use caution when lifting and check package for damage.
• Lift only at the designated hand-hold locations on the shipping container, or fully support the unit from underneath. A
shipment may include one or more boxes containing accessories.
• Before opening the container, inspect the packaging for any obvious signs of damage or mishandling.
• Write any discrepancy or visual damage on the bill of lading before signing.
• Allow the condensing unit to sit for 24 hours prior to start-up. The condensing unit can be placed in the installation
location, piped and evacuated during this time.
Note: CellarCool units are manufactured in the USA and tested prior to shipment.
• Review the packing slip to verify contents.
• Check the model number to ensure it is correct.
• Check that all factory options ordered are listed.
If any items listed on the packing slip do not match your order information,
contact CellarCool Customer Service immediately.
Check all shipped boxes for the following contents:
Please leave the unit in its original box until you are ready for installation. This will allow you to move the product safely without
damaging it. When you are ready to remove the product from the box, refer to the installation instructions.
TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit.
Evaporator Unit Box Condensing Unit Box
(1) CM Series evaporator unit (fan coil unit)
Evaporator installation hardware bag:
• (12) 2½” Phillips wood screws
• (12) #8 ⁄” Phillips pan-head screws
• (1) Bypass plug
• (1) ¼” barbed coupling
• (2) 3” strip of cork tape
Documentation bag:
• CM Series Version 2 owner’s manual
• CM Series Version 2 technician’s manual
• R-134a split system warranty checklist
(1) CM Series condensing unit
Accessory kit bag:
• Evaporator installation hardware bag
CM Series insulation blanket bag:
• CM Series insulation blanket
Condensing unit accessory kit:
• (1) Filter drier
• (1) Sight glass

CCM 062817
Page 6 | 1-855-235-5271
QUICK REFERENCE GUIDE
Top View
Bottom View
Mounting Bracket (Paintable)
Supply and Return Grille (Paintable)
Evaporator Unit (Fan Coil Unit)
Electrical Knockouts
Line Set Knockout (x6)
Note: The unit comes in black. The mounting bracket and front grille
are paintable, enabling you to match your desired color.
Top Panel
Electrical Knockout
Options
Line Set Knockout
Options

www.cellarcool.com | Page 7
CM SERIES
5
6
7
8
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY
KNOCKOUT LOCATIONS
Side View of Evaporator Unit
Top View of Evaporator Unit
1.5”
8.05”
14.1”
4.55”
1.75”
1.75”
34.25”
35.75”
35.75”
12.65”
6.58”
1.5”
4.57”
12.65”
20.4” 15.35”
20.4” 15.35”
Front View of Evaporator Unit
14.10”
12.65”
10.65”
12.65”
1.5”
4.58”
6.58”
1.45”
2”

CCM 062817
Page 8 | 1-855-235-5271
CM 3500 SPECIFICATIONS
Model 3500 Evaporator
(Fan Coil Unit)
3500 Condenser
(Air-Cooled Condensing Unit)
Cellar Size (cu. ft.) 1000
Dimensions 12.75”H x 14.5”W x 35.75”D
(17.10”H x 38.75”D w/mounting bracket) 13.5”H x 12”W x 18”D
BTUh with 90° air entering
the condenser coil* 3650
CFM 321 190
Refrigerant R-134a
Condensing Unit HP 1/3++
Voltage Rating 115V (20-amp dedicated circuit required)
Weight (lbs) 80 56
AMPS (Starting/Running) 2/1 23.5/6.8
dBA 58.5 65
Drain Line ¼” ID clear plastic tubing
Installation Evaporator unit (fan coil unit) is installed through the cellar ceiling. Condensing unit is
installed up to 100 line ft. from the evaporator unit.
Thermostat After market (24V thermostat not included)
Temp. Delta
55°F max temperature dierential between the cellar temperature and condensing unit intake
temperature
Warranty 2 years (parts and labor)
Mounting Bracket (Paintable)
Supply and Return Grille (Paintable)
Evaporator Unit (Fan Coil Unit)
Electrical Knockouts
Line Set Knockout (x6)
Inhaltsverzeichnis
Andere Cellar Cool Thermostat Handbücher
Beliebte Thermostat Handbücher anderer Marken

EWELLY
EWELLY EW-181 Bedienungsanleitung

Prolon
Prolon T1100 Montageanleitung

Computherm
Computherm Q20 Bedienungsanleitung

Heatmiser
Heatmiser neoStat Bedienungsanleitung

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Bedienungsanleitung

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Bedienungsanleitung