Code Blue CB 4 Series Service-Handbuch

800.205.7186 •www.codeblue.com
Administrator Guide
Installation | Configuration | Operation | Troubleshooting
CB 4 Series

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 2 of 65
CB 4 Series
Administrator Guide
WARNING
ONLY QUALIFIED PERSONNEL SHOULD INSTALL THESE UNITS. THE INSTALLATION
SHOULD CONFORM TO ALL LOCAL CODES. IN SOME COUNTRIES, A CERTIFIED ELECTRI-
CIAN MAY BE REQUIRED.
NOTICE TO USERS
Copyright © Code Blue Corporation. All rights reserved. This guide or software described herein, in
whole or part, shall not be reproduced, translated or reduced to any machine-readable form without
prior written approval from Code Blue Corporation.
CODE BLUE CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS GUIDE, THE
SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DIS-
CLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICU-
LAR PURPOSE WITH REGARD TO THIS GUIDE, THE SOFTWARE OR SUCH OTHER INFORMA-
TION. IN NO EVENT SHALL CODE BLUE CORPORATION BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL, OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR
OTHERWISE, ARISING OUT OF OR IN CONNECTIONS WITH THIS GUIDE, THE SOFTWARE
OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF.
Code Blue Corporation reserves the right to make any modications to this guide or the information
contained herein at any time without notice. The software described herein may also be governed
by the terms of a separate user license agreement.
Code Blue®is a registered trademark of Code Blue Corporation.

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 3 of 65
CB 4 Series
Administrator Guide
Table of Contents
(NOTE: Phone programming instructions can be found in the IP5000 and IA4100 Guides.)
Section Page
2 Introduction..........................................................................................5
3 Getting Started.....................................................................................7
4 Spare Parts...........................................................................................9
5 Power Requirements..........................................................................11
6 Legacy Power Requirements.............................................................14
7 Software Conguration...................................................................... 16
8 CB 4-s Low Voltage Exploded View..................................................17
9 CB 4-r Low Voltage Exploded View.................................................. 18
10 CB 4-s with Dual Faceplates Low Voltage Exploded View............. 19
11 CB 4-u Low Voltage Exploded View................................................. 20
12 CB 4-u High Voltage Exploded View................................................. 21
13 How to Replace LED Light Connectors............................................22
14 CB 4-s Installation Instructions........................................................ 24
15 CB 4-s with Dual Faceplates Installation Instructions.................... 26
16 CB 4-r Installation Instructions......................................................... 28
17 CB 4-u Installation Instructions........................................................ 30
18 CB 4 Series Remote Mount Beacon/Strobe Installation................. 33
19 S-1000/S-1050 Installation Instructions.............................................34
20 PoE Installation Instructions..............................................................36
21 CB 4 Series Pole Mount Installation Instructions............................37
22 CB 4 Series Curb Mount Installation Instructions...........................38
23 CB 4-u Solar Installation Instructions...............................................40
24 CB 4 Series 24V Standard Wiring (2020)..............................................41
25 CB 4 Series PoE Wiring (2020)..............................................................42
26 CB 4 Series 24V Standard Wiring (2015-2020)........................................43
27 CB 4 Series 24V Standard Wiring (prior to 2015).....................................44
28 CB 4-u 24V or Multi-Tap Power Brick Wiring (prior to 2015)...................45
29 CB 4-u Series Standard Wiring (after 2015) (with 24V Fuse Block)...................46
30 CB 4-u Series Standard Wiring (prior to 3/2013) (with Hammond Transformer).....47
31 CB 4-u Series Standard Wiring Diagram (after 2015) (with Triad Transformer).48

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 4 of 65
CB 4 Series
Administrator Guide
32 GSM Wireless Wiring Diagram (CB 4-u only)............................... 49
33 Cellular Retro Instructions (CB 4-u only)......................................50
34 Solar and WindAssist Wiring Diagram (CB 4-u only).................. 55
35 NightCharge®Wiring Diagram (CB 4-u only)................................ 56
36 WM-180 Wall Mount Installation Instructions.............................. 57
37 WM-180 Pole Mount Installation Instructions.............................. 60
38 Maintenance Schedule................................................................... 61
39 Locating Unit Serial Numbers........................................................63
40 Warranty........................................................................................... 64
41 Download Information.................................................................... 65

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 5 of 65
CB 4 Series
Administrator Guide
2 Introduction
The 4 Series Wall Mount Enclosures
Thank you for choosing the CB 4 Series for your Code Blue application.
The CB 4 Series is our basic communication unit designed for wall or pole installations in interior
and exterior applications. The all-steel housing and Code Blue’s speakerphone system meet the
need for a highly vandal resistant unit, while providing a cost-effective and reliable solution.
The CB 4 Series is a good choice for dorm and building entrances, hallways and transit centers.
The exclusive analog InterAct and VoIP speakerphones are designed for maximum reliability, vandal
resistance, auxiliary functions, mass notication control, and fault monitoring and reporting capabili-
ties. (see IA4100 or IP5000 guides for more information on our speakerphones)
Our unmistakable craftsmanship makes our enclosures the most rugged on the market, withstand-
ing the punishment of natural and man-made disasters. CB 4 Series units have a rugged steel
construction, industrial engineering grade reective graphics and weather, UV and grafti resistant
paint.
Other options include:
• IP and analog phones
• Low power consumption LED faceplate light
• 180° Public Address Speaker (PAS)
• Remote Mount Beacon/Strobe
• GSM – CB 4-u Only
• NightCharge®– CB 4-u only
• Solar – CB 4-u only
• Directory Plate
• Color IP Camera – CB 4-s with Dual Faceplates only
• Custom Cut-out Stainless Steel Plate – CB 4-u only

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 6 of 65
CB 4 Series
Administrator Guide
This guide contains all of the Code Blue CB 4 Series information for the CB 4-s, CB 4-u, and CB 4-r.
This guide contains a general overview of the CB 4 Series options and its application, installation
and wiring.
CB 4-u
CB 4-u
CB 4-s with
Dual Faceplates
CB 4-s with
CB 4-s
CB 4-s
CB 4-s
CB 4-r
CB 4-r

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 7 of 65
CB 4 Series
Administrator Guide
3 Getting Started
Basic Install Instructions
1. EIA/TIA, ANSI, CSA and BICSI cabling or similar standards shall be adhered to for proper
operation of Code Blue communication devices connected to copper or ber infrastructures.
Communications cable and electrical cable in the same conduit is not an acceptable instal-
lation and shall not be supported. Analog phones require a minimum of 23mA for proper
operation (26-29mA recommended).
2. Each analog speakerphone requires its own phone line or PBX extension. Multiple units
shall not be supported.
3. Speakerphones require programming before operation. Consult the User Guide or Admin-
istrator Guide enclosed with the unit or go to www.codeblue.com > Support > Downloads to
read or download manuals.
4. If you are installing IP speakerphones, please read the appropriate manuals and consult
with your Network Administrator.
5. Size electrical wiring based on length of run.
6. Consult the enclosed document packet for internal wiring instructions.
What’s Included
Quantity Part Description
1 Wall Anchor Kit - 4-3/8 Bolts, 4-Washers, 4-Rubber Washers 4-Cement Anchors
1 Security Bit
1 Enclosure
1 Access Plate – CB 4-u Only
1 URL listing sheet of Installation, Programming, Wiring & Warranty locations
1 Blank Stainless Steel Plate - CB 4-s with Dual Faceplates only
2 40 amp Batteries – CB 4-u Solar only
1 Solar Panel Assembly – CB 4-u only

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 8 of 65
CB 4 Series
Administrator Guide
Tools Required
CB 4-s and CB 4-r
1. Ladder to reach above unit – For Remote Beacon/Strobe Only
2. Drill and security bit for removing and inserting security screws on phone
3. 3/8 socket set to mount unit onto wall
CB 4-u
1. Ladder to reach above unit – CB4-u Solar or Remote Mount Beacon/Strobe Kit
2. Drill and security bit for removing and inserting security screws on phone and access plate
3. 3/8 socket set to mount unit onto wall
4. Banding Tool for Pole Mount Kit

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 9 of 65
CB 4 Series
Administrator Guide
4 Spare Parts
CB 4-s
Part Part Number
Faceplate Screws 41544 (6pk)
Power 4 Connector 24V 40109
Analog Surge Suppressor 41471
IP Surge Suppressor 41421
CB 4-s with Dual Faceplates
Part Part Number
Faceplate Screws 41544 (6pk)
Power 4 Connector 24V 40109
Analog Surge Suppressor 41471
IP Surge Suppressor 41421
Blank Stainless Steel Plate Assembly 40066
CB 4-r
Part Part Number
LED Faceplate Light 40196
Faceplate Screws 41544 (6pk)
Analog Surge Suppressor 41471
IP Surge Suppressor 41421
Power 4 Connector 24V 40109
CB 4-u
Part Part Number
LED Faceplate Light 40196
Faceplate Screws 41544 (6pk)
Access Plate Screws 41500 x 2
Manifold R/B 5-way 40101
Analog Surge Suppressor 41471
IP Surge Suppressor 41421

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 10 of 65
CB 4 Series
Administrator Guide
CB 4 Series Additional Options
Part Part Number
Solar Battery – CB 4-u only 41436
Solar Panel – CB 4-u only 40156
GSM Assembly – CB 4-u only - Solar only 40028
GSM Assembly – CB 4-u only – NightCharge®only 40026
Service Plate - Lexan w/graphics (This Location Being Serviced) 40208
Pole Mount Kit 40027
Triad Transformer 40VA 120V (will not power accessories) – CB 4-u only 41246
Remote Mount Beacon/Strobe Kit 40525
PoE Power Splitter Kit Assembly 41574
IP5000 Speakerphone FP1 50101
IP5000 Speakerphone FP2 50102
Keypad IP5000 Speakerphone 50103
IA4100 Speakerphone FP1 50001
IA4100 Speakerphone FP2 50002
Keypad IA4100 Speakerphone 50003
Directory Plate Assembly – CB 4-s with Dual Faceplates only 40057
Color Camera Assembly – CB 4-s With Dual Faceplates only 41420
Wind Operated Generator – CB 4-u only 40355
Remote Mount Beacon Kit (Photocell) 40528
Multi-tap Power Brick – CB 4-u only 40104
Curb Mount Stand – (Excludes the CB 4-u) 41432
Andere Handbücher für CB 4 Series
1
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Code Blue Gehäuse Handbücher