CS-iTEC S 505 Handbuch

English
Instruction and operation manual
S 505
Dew point meter (portable)

Dear Customer,
thank you for choosing our product.
The operating instructions must be read in full and carefully observed
before starting up the device. The manufacturer cannot be held liable
for any damage which occurs as a result of non-observance or non-
compliance with this manual.
Should the device be tampered with in any manner other than a
procedure which is described and specified in the manual, the warranty
is cancelled and the manufacturer is exempt from liability.
The device is destined exclusively for the described application.
CS-iT C offers no guarantee for the suitability for any other purpose.
CS-iT C is also not liable for consequential damage resulting from the
delivery, capability or use of this device.
2 S 505

Table of contents
1. Safety instructions.......................................................................4
2. Application.................................................................................7
3. Features.....................................................................................7
4. Technical Data............................................................................8
4.1 General.................................................................................8
4.2 lectrical Data........................................................................8
4.3 Accuracy ..............................................................................9
5. Dimensional drawing..................................................................10
6. Installation ..............................................................................10
6.1 Installation Procedure ...........................................................11
6.2 lectrical connection ............................................................14
7. Operation ................................................................................14
7.1 Buttons and connectors.........................................................14
7.2 Symbols on screen................................................................15
7.3 Main screen ........................................................................16
7.4 Basic operation ....................................................................16
7.5 Data logger..........................................................................17
7.6 File menu ...........................................................................18
7.7 Print menu ..........................................................................18
7.8 Bluetooth menu ...................................................................18
8. Application software ..................................................................19
8.1 S4M-S.................................................................................19
8.2 S4C-Handheld......................................................................19
9. Optional extra accessories..........................................................20
9.1 Portable bluetooth printer HDT 312.........................................20
9.2 Parking measuring chamber by-pass type................................21
9.3 SD card 4G..........................................................................22
10. Calibration..............................................................................22
10.1 Dew point calibration...........................................................22
10.2 Pressure calibration ............................................................23
11. Maintenance............................................................................24
12. Disposal or waste.....................................................................24
13. Warranty................................................................................24
S 505 3

1. Safety instructions
1. Safety instructions
Please chec if this instruction manual accords to the
product type.
Please observe all notes and instructions indicated in this
manual. It contains essential information which have to be
observed before and during installation, operation and
maintenance. Therefore this instruction manual has to be read carefully
by the technician as well as by the responsible user / qualified
personnel.
This instruction manual has to be available at the operation site of the
dew point meter at any time. In case of any obscurities or questions,
regarding this manual or the product, please contact the manufacturer.
WARNING!
Compressed air!
Any contact with quic ly escaping air or bursting
parts of the compressed air system can lead to
serious injuries or even death!
•Only use pressure tight installation material.
•Avoid that persons get hit escaping air or bursting parts of the
instrument.
•The system must be pressureless during maintenance work.
WARNING!
Voltage used for supply!
Any contact with energized parts of the product, may
lead to a electrical shoc which can lead to serious
injuries or even death!
•Consider all regulations for electrical installations.
•The system must be disconnected from any power supply during
maintenance work.
•Any electrical work on the system is only allowed by authorized
qualified personal.
4 S 505

1. Safety instructions
WARNING!
Permitted operating parameters!
Observe the permitted operating parameters, any
operation exceeding this parameters can lead to
malfunctions and may lead to damage on the
instrument or the system.
•Do not exceed the permitted operating parameters.
•Make sure the product is operated in its permitted limitations.
•Do not exceed or undercut the permitted storage and operation
temperature and pressure.
•The product should be maintained and calibrated frequently, at
least annually.
General safety instructions
•It is not allowed to use the product in explosive areas.
•Please observe the national regulations before/during installation
and operation.
Remar s
•It is not allowed to disassemble the product.
•Always use spanner to mount the product properly.
ATTENTION!
Measurement values can be affected by malfunction!
The product must be installed properly and
frequently maintained, otherwise it may lead to
wrong measurement values, which can lead to
wrong results.
Storage and transportation
•Make sure that the transportation temperature of the dew point
meter is between -30°C... 70°C.
•For transportation it is recommended to use the packaging which
comes with the sensor.
•Please make sure that the storage temperature of the sensor is
between -40°C... 65°C.
•Avoid direct UV and solar radiation during storage.
S 505 5

1. Safety instructions
•For the storage the humidity has to be <90%, no condensation.
6 S 505

2. Application
2. Application
The S 505 is a dew point meter which is designed to monitor the dew
point in industrial application within the permissible operating
parameters. These parameters can be found in the technical data
section.
The S 505 can measure and display the following values:
•Dew point of the compressed air or gas.
•Temperature of the compressed air or gas.
•Pressure of the compressed air or gas.
The default factory settings are: dew point in °Ctd. temperature in °C,
and pressure in bar.
The S 505 dew point meter is not developed to be used in explosive
areas. For the use in explosive areas please contact the manufacturer.
The S 505 dew point meter is mainly used in compressed air systems in
industrial environment.
3. Features
•Measures dew point, temperature and pressure.
•3 sensor solution available:
◦Sensor A: -100°Ctd ... -30°Ctd for trace moisture applications
◦Sensor B: -50°Ctd ... 50°Ctd for standard applications.
◦Sensor A+B: covering the full range of dew point measurement.
•Fast response time.
•Modern colour touch screen interface.
•Data logger, USB interface, bluetooth connection to portable
printer.
•Measuring / parking chamber for fast sensor response.
•Application software included.
S 505 7

4. Technical Data
4. Technical Data
4.1 General
Parameters Standard unit dew point: °Ctd
Standard unit temperature: °C
other units: °F, K
Standard unit humidity: %
Standard unit pressure: bar
Principle of measurement Capacitive method, Oscillating crystal
Sensor Sensor A: QCM technology
Sensor B: polymer
Measuring medium Non-corrosive gases
Measuring range Sensor A: -100°Ctd ... -30°Ctd
Sensor B: -50°Ctd ... 50°Ctd
Pressure: -0.1... 1.5 MPa
Temperature: -30°C... 50°C
Operating temperature 0°C... 50°C
Operating pressure -0.1... 1.6 MPa
Humidity of the meas.
medium
< 90%, no condensation
Casing material PC + ABS
Charging time 7 h (if switched on), 4 h (if switched off)
Protection class IP65
Dimensions See dimensional drawing on the next page
Display 2.8” colour graphic display
Weight 0.7 kg (with measuring chamber), 0.45 kg
(without measuring chamber)
4.2 Electrical Data
Power supply USB charger: 5 V, 2 A
8 S 505

4. Technical Data
4.3 Accuracy
Accuracy Dew point: ± 2°Ctd @ -50°C
Temperature:± 0.3°C
Pressure:± 0.005 MPa
Repeatability ± 0.5°C
Stated accuracy at Ambient process temperature of 23°C ± 3°C
and ambient humidity of < 90%, no
condensation
S 505 9

5. Dimensional dra ing
5. Dimensional drawing
6. Installation
Please make sure that all components listed below are included in your
package.
Qty Description Item No.
1Handheld meter with data logger and S4M-S
software P560 0505
10 S 505