Datcon DT9002 Bedienungsanleitung

DT9002
Intrinsically Safe Process Indicator
Operating Instructions

DT9002
2 20180621-V1
Contents
1. About this document .....................................................4
1.1. Function ................................................................................... 4
1.2. Target group............................................................................. 4
1.3. Symbolism used....................................................................... 4
2. For your safety ...............................................................5
2.1. Authorised personnel ............................................................... 5
2.2. Appropriate use........................................................................ 5
2.3. Warning about misuse ............................................................. 5
2.4. General safety instructions....................................................... 5
2.5. CE conformity........................................................................... 5
2.6. Safety information for Ex areas................................................ 6
2.7. Environmental instructions ....................................................... 6
3. Product description .......................................................7
3.1. Delivery configuration............................................................... 7
3.2. Principle of operation ............................................................... 8
3.3. Adjustment ............................................................................... 9
3.4. Storage and transport .............................................................. 9
4. Mounting.......................................................................10
4.1. General instructions ............................................................... 10
4.2. Main dimensions of the instrument ........................................ 10
4.3. Mounting procedure ............................................................... 11
5. Connecting ...................................................................13
5.1. Connecting into the current loop ............................................ 13
6. Display and manual controls ......................................18
6.1. The first start-up ..................................................................... 18
6.2. Characters and mnemonics appearing on the display ........... 19
6.3. Manual controls...................................................................... 22

DT9002
20180621-V1 3
7. Setting-up .....................................................................25
7.1. Typing the code (password) in ............................................... 25
7.2. The menu ............................................................................... 27
7.3. Display modes of limit output status (01. menu item) ............ 28
7.4. Setting up the limit outputs (02. and 03. menu items)............ 30
7.5. Limit output alarm mode......................................................... 36
7.6. Decimal point position (04. menu item).................................. 38
7.7. The physical value assigned to 4 mA (05. menu item) .......... 39
7.8. The physical value assigned to 20 mA (06. menu item) ........ 41
7.9. The number of averaged measurements (07. menu item)..... 43
7.10. Display refresh time (08. menu item) ................................... 45
7.11. Tests (09. menu item) .......................................................... 47
7.12. Changing the user code (10. menu item)............................. 49
7.13. Changing the supervisor code (11. menu item) ................... 51
7.14. Display operating modes (12. menu item) ........................... 53
7.15. Disable displaying the leader zeros (13. menu item) ........... 55
7.16. Clear minimum and maximum values (14. menu item)........ 57
7.17. Resetting the default settings (15. menu item)..................... 58
8. Fault rectification .........................................................59
8.1. Fault finding............................................................................ 59
8.2. Repairing................................................................................ 59
9. Dismounting .................................................................59
9.1. Dismounting procedure .......................................................... 59
9.2. Disposal ................................................................................. 59
10. Appendix.....................................................................60
10.1. Technical specification ......................................................... 60
10.2. Application example ............................................................. 62
10.3. Error messages.................................................................... 63
10.4. Messages of critical errors ................................................... 64
10.5. Description of the menu items.............................................. 65
10.6. Messages and error messages during setting up ................ 68
10.7. Setting up the instrument (Example).................................... 69
10.8. The limit outputs (training material)...................................... 71
10.9. ATEX Certification................................................................ 82

DT9002
4 20180621-V1
1. About this document
1.1. Function
This operating instructions manual has all the information
you need for quick set-up and safe operation of DT9002.
Please read this manual before you start setup.
1.2. Target group
This operating instructions manual is directed to trained
personnel. The contents of this manual should be made
available to these personnel and put into practice by them.
1.3. Symbolism used
Information, tip, note
This symbol indicates helpful additional information.
Caution, warning, danger
This symbol informs you of a dangerous situation that could
occur. Ignoring this cautionary note can impair the person
and/or the instrument.
Ex applications
This symbol indicates special instructions for Ex
applications.
•
List
The dot set in front indicates a list with no implied sequence.
→
Action
This arrow indicates a single action.
1
Sequence
Numbers set in front indicate successive steps in a
procedure.

DT9002
20180621-V1 5
2. For your safety
2.1. Authorised personnel
All operations described in this operating instructions
manual must be carried out only by trained and authorised
specialist personnel. For safety and warranty reasons, any
internal work on the instruments must be carried out only by
DATCON personnel.
2.2. Appropriate use
The DT9002 is a 4-20 mA loop-powered intrinsically safe
process indicator. Detailed information on the application
range of the DT9002 is available in chapter 3. Product
description.
2.3. Warning about misuse
Inappropriate or incorrect use of the instrument can give rise
to application-specific hazards, or demage to system
components through incorrect mounting or adjustment.
2.4. General safety instructions
The DT9002 is a high-tech instrument requiring the strict
observance of standard regulations and guidelines. The
user must take note of the safety instructions in this
operating instructions manual, the country-specific
installation standards as well as all prevailing safety
regulations and accident prevention rules.
2.5. CE conformity
The DT9002 is in conformity with the provisions of the
following standards:
MSZ EN 61326-1:2013 (EMC)
MSZ EN 60079-0:2013, MSZ EN 60079-11:2012 (ATEX)
MSZ EN 61010-1:2011 (safety)

DT9002
6 20180621-V1
2.6. Safety information for Ex areas
Please note the Ex-specific safety information for installation
and operation in Ex areas.
2.7. Environmental instructions
Protection of the environment is one of our most important
duties.
Please take note of the instructions written in the following
chapters:
•Chapter 3.4. Storage and transport
•Chapter 9.2. Disposal

DT9002
20180621-V1 7
3. Product description
3.1. Delivery configuration
Delivered items The scope of delivery encompasses:
•DT9002
•1 pc. of seal (for panel cut-out sealing)
•2 pcs. of srew clamps
•documentation:
this oparating instructions manual
quality certification
The instrument is built from the following main parts:
Main parts
1. instrument case
2. front panel with 3 membrane push buttons

DT9002
8 20180621-V1
3.2. Principle of operation
Area of application DT9002 is an intrinsically safe process indicator enable
linear process variables to be displayed in engineering units
in even the most hazardous plant areas: Zone 1, 2 or in the
safe area. Two isolated outputs are available with different
operating modes for limit signaling or for simple control
purposes.
DT9002 is housed in a DIN standard 144 x 72 mm ABS
case with IP 65 protection from the front and IP 30
protection from the back side, for installation on the control
panel.
Operating principle
The 4-20 mA current flows through a measuring resistor
and is converted by a 16 bit A/D converter into digital value.
The digital value is processed by a microcontroller. The use
r
may set up the the configuration parameters: scaling,
decimal point position, display refresh rate, signal filtering,
limit modes, limit values, etc. through the front panel
membrane keypad. The parameters stored in EEPROM. A
two level password protects the settings from unauthorised
changes.
Large 4 ½-digit, 20.5 mm height liquid crystal display make
process variables easily visible at a distance. A label
defining the appropriate engineering unit may be attached
to the right of the display.
DT9002 has two optically isolated transistor outputs for limit
signaling or for simple control purposes.
Power supply DT9002 is loop-powered from 4-20 mA signal, dropping less
than 2 V at 20 mA.

DT9002
20180621-V1 9
3.3. Adjustment
DT9002 can be adjusted through the 3 button front panel
keypad. All configuration parameters are stored in the
instrument EEPROM for unlimited period of time, even
when the loop current beeng switched off.
In factory setting the DT9002 displays the 4-20 mA loop
current with a resolution of three decimals.
The instrument doesn’t need any internal adjustment.
3.4. Storage and transport
This instrument should be stored and transport in places
whose climatic conditions are in accordance with Chapter
10.1. Technical specification, as described under the title:
Environmental conditions.
The packaging of DT9002 consist of enviroment-friendly,
recyclable cardboard is used to protect the instrument
against the impacts of normal stresses occurring during
transportation. The corrugated cardboard box is made from
environment-friendly, recyclable paper. The inner protective
material is polyfoam and nylon, which should be disposed of
via specialised recycling companies.

DT9002
10 20180621-V1
4. Mounting
4.1. General instructions
Use the enclosed seal when mounting DT9002 on panel to
assure IP 65 protection from the front side.
Electrostatic hazard! Clean only a moist cloth and
detergent.
Mounting positions
Select a mounting position you can easily read the display
reach for mounting and connecting the instrument and that
minimises the hazard of water, dust or dump getting into the
instrument.
4.2. Main dimensions of the instrument
Inhaltsverzeichnis
Andere Datcon Messgerät Handbücher

Datcon
Datcon DT4120 Series Bedienungsanleitung

Datcon
Datcon DT7000 Bedienungsanleitung

Datcon
Datcon DT4220 E Series Bedienungsanleitung

Datcon
Datcon DT9500 Bedienungsanleitung

Datcon
Datcon PQRM5300 33 U I Series Bedienungsanleitung

Datcon
Datcon DT9502 Bedienungsanleitung

Datcon
Datcon DT4227 UI Bedienungsanleitung

Datcon
Datcon DT4240 Series Bedienungsanleitung

Datcon
Datcon DT9000 Bedienungsanleitung

Datcon
Datcon DT920 Bedienungsanleitung