E.T. Systems Drive 500 Bedienungsanleitung

ET DRIVE 500/600 USER 2016.001.001
End User Instrucons
500kg Slide Gate Operators
500 600
Low Trac High Trac
www.et.co.za
NiceET
Designed, manufactured and
supported by ET NICE (Pty) Ltd

2
Introducon.
Page 3 Be Safe! Instrucons, warnings and obligaons.
Page 4 Technical specicaons.
Page 5 How to use the manual override.
Operang mode denions and examples.
Page 6 Collision sensing and safety overload rounes.
Page 7 Safety infra-red beams funcon. All modes except P.I.R.A.C. auto-close mode.
Page 8 “BT” Buon triggers - Standard mode.
Page 9 “BT” Buon triggers - Simple auto-close mode.
Page 10 “BT” Buon triggers - Condominium auto-close mode.
Page 11 “BT” Buon triggers - P.I.R.A.C. auto-close mode.
Page 12 “PED” Pedestrian trigger. With no safety beams installed.
Page 13 “PED” Pedestrian trigger. With safety beams installed.
Page 14 “Loop” trigger.
Page 15 Auxiliary relay modes - Strike lock mode.
Page 16 Auxiliary relay modes - Magnec lock mode.
Page 17 Auxiliary relay modes - Courtesy light mode.
Page 18 Auxiliary relay modes - Receiver relay mode.
Page 19 Posive close mode.
Page 20 Holiday lock-out mode.
Page 21 Auto-close override/party mode.
Page 22 Tamper alarms.
Troubleshoong.
Page 23 Status LED indicaons and buzzer guide.
Page 24 Warranty.
For any assistance with this product, which is not covered in this manual, please contact your service provider/installer.
Contact details of service provider/installer:
Company name:
Technician:
Contact number:
Email address:
Date of installaon:
Company stamp:

3
Be Safe!
WARNING!! These are the general safety obligaons for the installers and users of ET Systems
automaon equipment.
1. Only suitably qualied persons, may install, repair or service the product. Unless expressly indicated in the user instrucons, no
user serviceable components can be found inside any ET Systems automaon product.
2. It is important for personal safety to study and follow all the instrucons carefully. Incorrect installaon or misuse may cause
serious personal harm.
3. Keep the instrucons in a safe place for future reference.
4. This product was designed and manufactured, strictly for the use indicated in the accompanying documentaon. Any other use
not expressly indicated in the documentaon, may damage the product and/or be a source of danger. ET NICE (Pty) Ltd cannot
accept responsibility for improper use or incorrect installaon of this product.
5. ET NICE (Pty) Ltd cannot accept responsibility if the principles of good workmanship are disregarded by the installer.
6. ET NICE (Pty) Ltd cannot accept responsibility regarding safety and correct operaon of the automaon, if other manufacturers’
equipment is added to this product.
7. Do not make any modicaons or alteraons to this product. Do not substute any component of this product with any other
component not expressly designed into this product.
8. Anything other than expressly provided for in the accompanying instrucons is not permied.
Prior to installaon:
1. All unnecessary ropes, chains and fasteners must be removed and all unnecessary latches or locks must be disabled from locking.
2. The gate or door must be balanced correctly where it, neither opens nor closes from any posion under its own load. When
operated by hand the gate or door should be free of hindrance and easily moved (In the case of a garage door if the balancing
springs need to be adjusted the adjustment should only be carried out by a qualied and experienced person).
3. The construcon of the gate or door must be sound and automatable. It is the responsibility of the installer to ensure that the
mechanical components of the gate or door system are sucient to withstand the necessary forces in cases of overload.
4. It is the responsibility of the installer to ensure the gate or door is suciently trapped within its range of travel by means of
mechanical ends of travel stoppers.
5. Ensure all xed mounng points, such as the wall above the door in a garage door system or the posts in a swing gate system, are
sound and strong enough to allow proper xing of the operator.
6. It is the responsibility of the installer to ensure the installed posion selected for this product, falls within the limitaons of the
products ingress protecon rang.
7. Ensure the area of installaon is not subject to explosive hazards. There should be no volale gasses or fumes as these can present
a serious safety hazard.
8. All ET Systems garage door operators are supplied with a sealed 15A safety plug on lead for use in an electrical code of pracce
approved plug point. Do not extend, modify or replace the plug lead unless duly qualied as an electrician. Before installing the
unit, ensure the mains supply is switched o.
9. ET Systems gate operators are supplied with a terminal connecon for the electrical supply beneath the screwed down cover of
the operator. In the case of a model requiring 220Vac supply at the operator, an all pole negavely biased switch, with a contact
opening of greater than 3mm must be installed within 1,5m of the operator. This switch must be clear of all workings of the system
and must be in a posion secure from public access. This switch and its connecons must be inspected and passed by a cered
electrician prior to using it.
10. It is the responsibility of the installer to ascertain that the designated persons (including children) intended to use the system,
do not suer reduced physical sensory or mental capabilies, or lack of experience and knowledge, unless they have been given
supervision or instrucon concerning the use of the system by a person responsible for their safety.
11. The drive may not be installed on a door incorporang a wicket door, unless the drive is disabled by the release of the wicket door.
(Wicket door :- A pedestrian door within the main gate or door)
1. Ensure the working area is clear of obstrucons and obstacles.
2. Install the safety warning scker within clear view of where the gate or door will be operated from. Typically this would be
adjacent to any xed trigger switches or on the gate or door itself.
3. The emergency manual release must be installed where it is no higher than 1.8m from the oor level. This would apply to the cord
in a garage installaon or the lockable lever in a gate installaon.
4. Any addional xed door control switches such as wall consoles or keypads, if installed, must be at a height of at least 1.5m, within
clear sight of the gate or door and away from any moving components of the system.
During installaon:
Connued overleaf.......

4
5. It is highly recommended that a set of safety infra-red beams be used in conjuncon with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or gate.
6. Over and above the recommendaon to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automac closing feature. It is recommended that a warning light be ed to any automaon system.
7. The emergency manual release instrucon label must be installed on or adjacent to the emergency manual release mechanism.
Aer installaon - It is the responsibility of the installer to ensure the users:
1. Is procient in the use of the manual emergency release mechanism.
2. Is issued with the documentaon accompanying this product.
3. Understands that the gate or door may not be operated out of clear sight.
4. Ensures that children are kept clear of the gate or door area at all mes, and that children do not play with the remote transmiers
or any xed trigger switches linked to the system.
5. Is instructed not to aempt to repair or adjust the automaon system and to be aware of the danger of connuing to use the
automaon system in an unsafe condion before a service provider aends to it.
6. Is procient in tesng the unit’s safety obstrucon sensing system.
7. Is aware of what to check for with regards to wear and tear that may need to be aended to from me to me by the service
provider.
8. Is aware that a fagued baery may not be disposed of in the general refuse and must be handed in at a baery merchant for safe
disposal. Before removing the baery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the baery must be removed rst.
Technical specicaons.
TECHNICAL SPECIFICATIONS
Technical Data Drive 500 Drive 600
Rated gate mass. 500kg 500kg
Maximum gate travel. 99m 99m
Primary power supply to gate. 16Vac @ 1A 50Hz – 60Hz 220 – 240Vac @ 50Hz – 60Hz
Peak power consumpon at gate. 26W 240W
Electrical class. Class 3 Class 1
Motor voltage. 12Vdc 12Vdc
Motor current. Current limited to 25A. Current limited to 25A.
Duty cycle maximum.
See determining your duty cycle on page 7. 25% with 220Vac present 98% with 220Vac present
Number of operaons on baery reserve.
(Baery health and charge level at me of
power failure dependent. Calculated on a 5m
gate with rolling resistance of <10kgf)
100 using the standard 7Ah baery within
24hrs.
100 using the standard 7Ah baery within
24hrs.
Gate speed.
(Gate load and power supply dependent) Up to 28m/min. Up to 30m/min.
Rated Load. 300N 300N
Operang temperature range. -10 to 50° C (14F to 122F) -10 to 50° C (14F to 122F)
An-crushing safety sensing. Yes – Electronic gate proling Yes – Electronic gate proling
Auxiliary supply output. 12Vdc @ 500mA 12Vdc @ 500mA
Built in baery charger. Mulple stage auto-calibrang 1A Mulple stage auto-calibrang 1A
Receiver format. ET BLU MIX © backward compable with ET
BLUE (Rolling code)
ET BLU MIX © backward compable with ET
BLUE (Rolling code)
Receiver frequency. 433.92MHz 433.92MHz
Receiver channels. 4CH (BT, PED, Aux relay, Holiday lock-out) 4CH (BT, PED, Aux relay, Holiday lock-out)
Receiver memory capacity. 1023 users 1023 users
All users can be allowed control of all channels. Yes Yes
Ingress protecon IPX4 IPX4
Physical dimensions See next page. See next page.

5
How to use the manual override.
Move gate open and closed by hand.
To disengage the gearbox (Manual mode)
1. Raise lock cover.
2. Insert the key.
3. Turn the key clockwise.
To disengage the gearbox (Manual mode)
4. Swing the manual override lever 90o
to the gearbox.
(Manual mode)
5. Manoeuvre the gate by hand.
To re-engage the gearbox (Normal mode)
6. Swing the manual override lever
back into it recess in the gearbox.
To re-engage the gearbox (Normal mode)
7. Turn the key counter clockwise.
8. Remove the key.
9. Lower the lock cover.
To re-engage the gearbox (Normal mode)
10. Ensure the gearing is engage by
pushing or pulling the gate unl the
gearing “clicks” in.

6
Basic operang features. Collision sensing and safety overload rounes.
In the case of the gate colliding with an obstrucon such as a person passing through the entrance way, the collision sensing will automacally detect
the collision and the system will run a safety overload roune.
Safety overload roune while gate is opening.
Acon Response
Gate collides with a
pedestrian for example.
Gate stops
opening.
Once gate has stopped.
Gate reverses
momentarily
to release
pressure.
No buzzer tones.
Aer reversing
momentarily.
Gate stops and
waits for next
trigger to close.
No buzzer tones.
Safety overload roune while gate is closing.
Acon Response
Gate collides with a
pedestrian for example.
Gate stops
closing.
Once gate has stopped.
Gate reverses
back to the full
open posion.
No buzzer tone.
Aer reversing to the
full open posion.
Gate remains
in the full open
posion unl
the next trigger
to close.
No buzzer tone.
x1 STOP
STOP
STOP
x1 STOP
STOP

7
Safety infra-red beams funcon.
All modes except P.I.R.A.C.
Basic operang
features
If the safety beam input has been switched on, the control card will constantly monitor to ensure a set of safety beams is installed.
NB! If the BT input mode has been set to either simple auto-close or condominium mode, the safety beam input is required.
Below is an example of how the gates will behave whenever the safety beam input is acvated.
Acon Response
Momentary BT trigger. Gate begins
opening. No buzzer tones.
Safety beam input
triggered while gate is
opening.
Gate connues
opening. No buzzer tones.
At full open posion.
Safety beam input sll
triggered.
Gate stops and
waits for next
trigger to close.
No buzzer tones.
Momentary BT trigger.
Trigger is
ignored and
gate remains
open.
No buzzer tones.
Safety beam input
cleared.
Gate remains
in the full open
posion unl
the next trigger
to close.
No buzzer tone.
Momentary BT trigger. Gate begins
closing. No buzzer tone.
Safety beam input while
the gate is closing.
Gate stops and
reverses open. No buzzer tone.
At the full open
posion.
Gate stops and
waits for next
trigger to close.
No buzzer tone.
Momentary BT trigger. Gate begins
closing. No buzzer tone.
Gate closed.

8
Basic operang
features
“BT” Buon triggers.
Standard mode.
The BT funcons are the primary full gate opening funcons for motor vehicle access.
There are two ways of acvang the “BT” funcons on this control card. Either via the hardwired BT input or the BT receiver channel.
In Standard mode the gates respond to each BT trigger.
In Standard mode you have access to the following advanced features: - Holiday lock-out and Party mode.
Acon Response
Momentary BT trigger. Gate begins
opening. No buzzer tones.
At full open posion. Gate stops. No buzzer tones.
Momentary BT trigger. Gate begins
closing. No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
Momentary BT trigger. Gate stops. No buzzer tones.
Momentary BT trigger. Gate begins
closing. No buzzer tones.
At full closed posion. Gate stops. No buzzer tones.
STOP
Gate closed.

9
“BT” Buon triggers.
Simple auto-close mode.
Basic operang
features
The BT funcons are the primary full gate opening funcons for motor vehicle access.
There are two ways of acvang the “BT” funcons on this control card. Either via the hardwired BT input or the BT receiver channel.
Simple auto-close mode funcons exactly the same as standard mode except that the gates will close automacally aer the programmed BT au-
to-close mer has med out.
In this mode you have access to the following advanced features: - Holiday lock-out and Party mode.
NB! For any auto-close feature to work, a pair of safety infra-red beams must be installed and funconing correctly. If no safety infra-red beams are
installed then the gates will open but not close again.
Acon Response
Momentary BT trigger. Gate begins
opening. No buzzer tones.
At full open posion. Gate stops. No buzzer tones.
Momentary BT trigger
or auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing. No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
Momentary BT trigger. Gate stops. No buzzer tones.
Momentary BT trigger
or auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing. No buzzer tones.
At full closed posion. Gate stops. No buzzer tones.
STOP
0
20 sec.
0
20 sec.
Gate closed.

10
Basic operang
features
“BT” Buon triggers.
Condominium auto-close mode.
The BT funcons are the primary full gate opening funcons for motor vehicle access.
There are two ways of acvang the “BT” funcons on this control card. Either via the hardwired BT input or the BT receiver channel.
In Condominium auto-close mode, all BT triggers are treated as open, keep opening, keep open or re-open triggers. The gates will only close once the
BT auto-close mer has med out.
In Condominium auto-close mode the following advanced features are NOT available: - Holiday lock-out and Party mode.
NB! For any auto-close feature to work, a pair of safety infra-red beams must be installed and funconing correctly. If no safety infra-red beams are
installed then the gates will open but not close again.
Acon Response
Momentary BT trigger. Gate begins
opening. No buzzer tones.
Momentary BT trigger
while gate is opening.
The trigger is
ignored and the
gate connues
opening.
No buzzer tone.
At full open posion.
Gate stops
and auto-close
mer starts
counng down.
No buzzer tones.
Momentary BT trigger.
Gate remains
open and auto-
close mer
resets.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing. No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
At full open posion.
Gate stops
and auto-close
mer starts
counng down.
No buzzer tones.
Auto-close mer
meout. Safety beam
input not triggered.
Gate begins
closing. No buzzer tones.
At full closed posion. Gate stops. No buzzer tones.
0
0 sec.c.
0
0 sec.c.
0
20 sec.
0
20 sec.
0
20 sec.
Gate closed.
Andere Handbücher für Drive 500
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere E.T. Systems Toröffner Handbücher