Cycling Through Measurement Parameters
Press the Mode button briefly to change the displayed parameter.
The instrument will cycle through the parameters in the following
order:
Wind Speed » Wind Chill » emperature » Relative Humidity » Heat
Index » Dew Point » Barometric Pressure » Pressure Altitude.
Hold Function
To freeze the current reading, press the Backlight button for more
than 2 seconds. Press it again for more than 2 seconds to exit this
mode.
Changing the Measurement Units
n any measurement parameter mode briefly press the Units button
to change the measurement unit displayed. For example, in wind
speed mode choose between mph, m/s, ft/min, knots, and km/h.
Max/Min/Avg Value Measurement Function
This function allows you to track the maximum, minimum and
average of your readings for any parameter each time you power on
the unit.
n any measurement parameter mode briefly press the Max button
to display the Maximum Reading. A second press will display the
Minimum, a third press will display the Average and a fourth press
will return the meter to the real-time current readings.