Francotyp-Postalia PostBase Bedienungsanleitung

PostBase
Warning!
Information contained in this document is proprietary and the sole property of
Francotyp-Postalia.
This information is confidential and for internal use only. Any disclosure, transmittal or
reproduction to a third party will be procecuted. Francotyp-Postalia reserves the right to
take action, to the fullest extend allowed by law, against both the party discloses
Francotyp-Postalia's proprietary information and the party that recieves it.
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

PostBase
pictogram legend:
The following notes only provides information. In most no error has occured.
Customer and Hotline may be able to solve the problem without a technical
visit.
Technician repair or service required. Check whether on-site visit or use of
bing-in service is required for the product in question.
To continue assessment Hotline or Second-Level-Support require
transmission of remote-diagnostics-data.
Note about the transmission of remote-diagnostic-data:
Whenever possible, the customer always should transmit machine remote-diagnostics-data a technican visit occurs Wherever the
Remote-diagnostics symbol appears in the following pages, transmission of the data is required for further analysis of the error message.
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
00030000 Software error (init failed) internal information:
>> PCALC_ERROR << / >> INIT_FAILED <<
>> Initialization of the product calculation failed. <<
00030001 Postage rate table error internal information:
>> PCALC_ERROR << / >> LOAD_PROD_TABLES_FAILED <<
>> Loading the XML file containing the product tables failed. <<
00030002 Product calculation failed internal information:
>> PCALC_ERROR << / >> SET_ENVIRONMENT_FAILED <<
>> Initialization of the FM environment in the product calculation failed. <<
00030003 Product calculation could not be started. internal information:
>> PCALC_ERROR << / >> CALCULATE_PRODUCT_START_FAILED <<
>> Start of the product calculation failed. <<
00030004 Product calculation failed internal information:
>> PCALC_ERROR << / >> CALCULATE_PRODUCT_FAILED <<
>> The real product calculation failed. <<
00030005 Product calculation failed internal information:
>> PCALC_ERROR << / >> RESTORE_PROD_DESC_FAILED <<
>> Restore product description failed. <<
00030006 Product calculation failed internal information:
>> PCALC_ERROR << / >> HANDLE_MENU_SELECTION_FAILED <<
>> Performing next product calculation step after menu selection failed. <<
00030007 Product calculation failed internal information:
>> PCALC_ERROR << / >> HANDLE_ACTION_SHOW_MENU_FAILED <<
>> Update product calculation menu failed. <<
00030008 Product calculation failed internal information:
>> PCALC_ERROR << / >> PCALC_WEIGHT_CHANGED_FAILED <<
>> Product calculation with changed weight failed. <<
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
00030009 Product calculation failed internal information:
>> PCALC_ERROR << / >> RM_UPDATE_PCALC_ITEMS_FAILED <<
>> Update of the product calculation related ready mode itmes failed. <<
0003000A Product calculation failed internal information:
>> PCALC_ERROR << / >> HANDLE_ACTION_REQUEST_VALUE_FAILED <<
>> Handle request value and performing next step of product calculation failed. <<
0003000B Product calculation failed internal information:
>> PCALC_ERROR << / >> CALCULATE_PRODUCT_BACK_FAILED <<
>> To go one calculation step back. <<
0003000C Product calculation failed internal information:
>> PCALC_ERROR << / >> HANDLE_NEXT_ACTION_FAILED <<
>> Handling the next action requested from the Pawn script failed. <<
0003000D Product calculation failed internal information:
>> PCALC_ERROR << / >> HANDLE_ACTION_SELECT_INDEX_FAILED <<
>> Handle request value and performing next step of product calculation failed. <<
0003000E Product calculation failed internal information:
>> PCALC_ERROR << / >> HANDLE_ACTION_SELECT_VALUE_FAILED <<
>> Handle request value and performing next step of product calculation failed. <<
0003000F Product calculation failed internal information:
>> PCALC_ERROR << / >> WRONG_RESULT_TYPE <<
>> Invalid type of the action result <<
00030010 Product calculation failed internal information:
>> PCALC_ERROR << / >> WRONG_DISPLAY_TYPE <<
>> Invalid type of the display object, neither text nor bitmap. <<
00030011 Product calculation failed internal information:
>> PCALC_ERROR << / >> WRONG_SELECTED_INDEX <<
>> Selected index is out of range <<
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
00030012 Product calculation failed internal information:
>> PCALC_ERROR << / >> MEMKEY_INIT_FAILED <<
>> Initialization of the memory keys failed. <<
00030013 Product calculation failed internal information:
>> PCALC_ERROR << / >> PCALC_WITH_SELECTED_MEMORY_KEY_FAILED <<
>> Product calculation with the selected memory key failed. <<
00030014 Product calculation failed internal information:
>> PCALC_ERROR << / >> GET_ENVIRONMENT_FAILED <<
>> Get information of the FM environment to initialize the product calculation failed. <<
00030015 Product calculation failed internal information:
>> PCALC_ERROR << / >> NO_PRODUCT_AVAILABLE <<
>> LetterInfo has no product assigned. <<
00030016 Product calculation failed (wrong country) internal information:
>> PCALC_ERROR << / >> INVALID_COUNTRY_ISO_CODE <<
>> Occured if producttable-country-code and country-variant-code not the same <<
00030017 Product calculation failed (wrong Zip-Code) internal information:
>> PCALC_ERROR << / >> WRONG_ZIP_CODE <<
>> The zip code stored in uPSD is to short or not present <<
00030018 Product calculation failed internal information:
>> PCALC_ERROR << / >> SET_PROPERTIES_FAILED <<
>> The environment properties could not be set <<
00030019 Product calculation failed (wrong Zip-Code) internal information:
>> PCALC_ERROR << / >> INVALID_SOURCE_LOCATION <<
>> The source zip code does not match the psd zip code <<
0003001A Product calculation failed (wrong Zip-Code) internal information:
>> PCALC_ERROR << / >> WRONG_DESTINATION_ZIPCODE <<
>> The destination zip code is invalid. Zone calculation is impossible. <<
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
0003001B Product calculation failed (wrong Zip-Code) internal information:
>> PCALC_ERROR << / >> ZIP2ZONE_FAILED <<
>> Zone calculation failed. <<
0003001C Product calculation failed (wrong Zip-Code) internal information:
>> PCALC_ERROR << / >> INVALID_ZIP2ZONE_DATA <<
>> The zip2zone database is invalid <<
0003001D Product calculation failed internal information:
>> PCALC_ERROR << / >> RM_UPDATE_MEM_KEYS_FAILED <<
>> Memory keys could not be updated. <<
0003001E Product calculation failed (Product table
missing) internal information:
>> PCALC_ERROR << / >> NO_PRODUCT_TABLE_FILE <<
>> File with product table data (*.bin) does not exist. <<
0003001F Product calculation failed internal information:
>> PCALC_ERROR << / >> NO_PAWN_FILE <<
>> File with pawn scripts (*.amx) does not exist. <<
00030020 Product calculation failed internal information:
>> PCALC_ERROR << / >> TOO_MUCH_MEMORY_KEYS <<
>> The number of memory keys received from the extern controller exceeds the size of the
persistent storage. <<
00030021 Product calculation failed internal information:
>> PCALC_ERROR << / >> DUPLICATE_MEMORY_KEY_INDICES <<
>> There are duplicate indices of the memory keys. <<
00030022 Product calculation failed internal information:
>> PCALC_ERROR << / >> WRONG_MEMORY_KEY_RATE_VERSION <<
>> The rate version of the memory key received from the extern controller is wrong. <<
00030023 Product calculation failed internal information:
>> PCALC_ERROR << / >> INVALID_MEMORY_KEY_INDEX <<
>> Memory key index does not match any memory key. <<
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
00030024 Product calculation failed internal information:
>> PCALC_ERROR << / >> INVALID_MEMORY_KEY_PRODUCT_DESC <<
>> The product description of the selected memoy key is invalid. <<
00030025 Product calculation failed internal information:
>> PCALC_ERROR << / >> INVALID_PRODUCT_OF_MEMORY_KEY <<
>> The calculated product of the selected memoy key is invalid. <<
00030026 Product calculation failed internal information:
>> PCALC_ERROR << / >> SELECT_MEMORY_KEY_FAILED <<
>> Selection of a memory key failed. <<
00030027 Product calculation failed internal information:
>> PCALC_ERROR << / >> NO_MEMORY_KEY_AVAILABLE <<
>> No memory keys are available. <<
00030028 Product calculation failed internal information:
>> PCALC_ERROR << / >> VALIDATE_MEMORY_KEYS_FAILED <<
>> validation of the memory keys failed <<
00040000 >> OPERATION_ERROR << internal information:
>> OPERATION_ERROR << / >> READ_FAILED_MESSAGE_EMPTY <<
>> Parsing of a message requested more bytes than received <<
00040002 >> OPERATION_ERROR << internal information:
>> OPERATION_ERROR << / >> WRITE_FAILED_ALLOC_EXCEPTION <<
>> An allocation exception occured during message creation <<
00040003 >> OPERATION_ERROR << internal information:
>> OPERATION_ERROR << / >> MAX_MESSAGE_SIZE_EXCEEDED <<
>> Message size is larger than the processable maximum. <<
00040004 Invalid message from external program
received. internal information:
>> OPERATION_ERROR << / >> INVALID_MESSAGE_CONTENT <<
>> An error occured while parsing the message content. <<
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
00060000 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> IODEVICE_READ_ERROR <<
>> The call of IODevice read function returns an error <<
00060001 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> IODEVICE_WRITE_ERROR <<
>> The call of IODevice write function returns an error <<
00060002 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> SET_RX_MODE_ERROR <<
>> The request to set the serial receive mode has failed <<
00060003 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> SET_TX_MODE_ERROR <<
>> The request to set the serial transmit mode has failed <<
00060004 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> CREATE_SIGNAL_ERROR <<
>> This error indicates that the creation of a signal object has failed <<
00060005 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> CREATE_MUTEX_ERROR <<
>> This error indicates that the creation of a mutex object has failed <<
00060006 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> START_TASK_ERROR <<
>> The start up of the serialDevice task has failed <<
00060007 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> REQUEST_RESOURCE_ERROR <<
>> The request of the IODevice object has failed <<
00060008 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> IODEVICE_READ_TIMEOUT_ERROR <<
>> The timeout of the read request has expired <<
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
00060009 >> SERIAL_DEVICE_ERROR << internal information:
>> SERIAL_DEVICE_ERROR << / >> IODEVICE_WRITE_TIMEOUT_ERROR <<
>> The timeout of the write request has expired <<
00070000 Feeder: Sensor adjustment failed Sensor calibration failed. (Automatic Feeder = AF)
Please make sure that letter path is cleared and sensors are clean.
remarks to subcode 1:
AF software version < 21012.32.5 not used in
AF software version => 21012.32.5 used to point to the faulty sensor adjustment 0x00332211 :
Status LS3 LS2 LS1 ('01' means failure)
e.g. 00010100 =
00 = not used / 01 = LS3 error / 01 = LS2 error / 00 = LS1 = ok
LS3 and LS2 show an error and can not be adjusted. Please check sensors.
00070001 Feeder: Endcoder test failed No feedback from Encoder during encoder test of separation motor.
00070002 Feeder: Endcoder test failed The result returned from the encoder test of the separation motor is incorrect.
00070003 Feeder: Endcoder test failed The result returned from the encoder test of the transport motor is incorrect.
00070004 Feeder: Endcoder test failed No feedback from Encoder during encoder test of transport motor.
00070005 Feeder: Endcoder test failed No feedback from Encoder during transport motor speed control..
00070006 Feeder: Endcoder test failed internal information:
>> FEEDER_ERROR << / >> TRANSPORT_ENCODER_FEEDBACK_MISSING <<
>> During transport motor speed control there is no encoder feedback. <<
00070007 Feeder: Letter jam! Please clear the transport
path. internal information:
>> FEEDER_ERROR << / >> PAPER_JAM <<
>> Paper jam detected by letter transport <<
00070009 Feeder: Sensor adjustment failed The sensor calibration can not be performed.
Please make sure that the drive letter is free, and no scraps of paper blocking the sensors.
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase

diagnostic
code subcode1
subcode2 diagnostic message information remedy
0007000D Feeder: Sensor adjustmen failed Normal feeding not possible because of blocked sensors.
Please clear paper path and restart machine.
0007000E Feeder: The hood of the automatic feeder is
open. Please close. The hood of the automatic feeder is open.
Please close.
0007000F Feeder: Unacceptable letter size Unacceptable letter size.
Letter is shorter than allowed (140mm). This is not allowed.
00070010 Feeder: Envelope seal flap not found The letter flap could not be found in SEAL mode.
00070011 Feeder: Could not feed the letters Could not feed the required number of letters.
00070012 Feeder: Mode change not allowed It is not allowed to change the seal mode during mail processing
00070013 Feeder: Ccommunication error CAN bus communication error has occurred.
Please verify that the connection (cable) is done right. (Screwed cable)
00070014 Feeder: Could not feed the letters A start command received while no letters were available.
Please insert letters correctly in the feeder.
00070015 Feeder: Encoder test failed A letter covers the area of the transport motor; Encoder test is not allowed.
Please clear letter path.
00070016 Feeder: Encoder test failed A letter covers the area of the separation motor; Encoder test is not allowed.
Please clean the area of the separation motor.
0007001B Feeder: Encoder test failed No feedback from encoder during test of separation motor.
0007001C Feeder: Endcoder test failed No feedback from encoder during test of separation motor.
0007001D Feeder: Encoder test failed No feedback from encoder during test of separation motor.
0007001E Feeder: Encoder test failed No feedback from encoder during test of separation motor.
create: 01/24/2014 18:27:16 (C) Francotyp-Postalia PostBase